G Ries, A Breit, J Kummermehr, N Breiter, K R Trott
{"title":"rent -项目:放射生物学结果和计划临床应用。","authors":"G Ries, A Breit, J Kummermehr, N Breiter, K R Trott","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Various preclinical tests have been performed to determine the properties of fast neutrons of a mean energy of 2 MeV produced by an U-235 converter plate in the research reactor of the Technical University of Munich. Experiments have been carried out using two specific beams denoted as RENT I and RENT II (RENT stands for Reaktor Neutron Therapy). RENT II is the unmodified beam with a dose rate of 65 rd/min and a gamma-contamination of nearly 50% in 2 cm depth of a perspex phantom. In RENT I the gamma-component is reduced to 25% after filtration of the beam with 2.5 cm lead, whereas the total dose rate is reduced to 22 rd/min.</p>","PeriodicalId":21981,"journal":{"name":"Strahlentherapie","volume":"161 12","pages":"791-3"},"PeriodicalIF":0.0000,"publicationDate":"1985-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The RENT-project: radiobiological results and planned clinical application.\",\"authors\":\"G Ries, A Breit, J Kummermehr, N Breiter, K R Trott\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Various preclinical tests have been performed to determine the properties of fast neutrons of a mean energy of 2 MeV produced by an U-235 converter plate in the research reactor of the Technical University of Munich. Experiments have been carried out using two specific beams denoted as RENT I and RENT II (RENT stands for Reaktor Neutron Therapy). RENT II is the unmodified beam with a dose rate of 65 rd/min and a gamma-contamination of nearly 50% in 2 cm depth of a perspex phantom. In RENT I the gamma-component is reduced to 25% after filtration of the beam with 2.5 cm lead, whereas the total dose rate is reduced to 22 rd/min.</p>\",\"PeriodicalId\":21981,\"journal\":{\"name\":\"Strahlentherapie\",\"volume\":\"161 12\",\"pages\":\"791-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strahlentherapie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strahlentherapie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在慕尼黑工业大学的研究反应堆中进行了各种临床前试验,以确定平均能量为2 MeV的U-235转炉板产生的快中子的性质。实验使用了两个特定的光束,分别表示为RENT I和RENT II (RENT代表反应堆中子疗法)。RENT II是未经修饰的光束,剂量率为65 rd/min,在有机玻璃模体的2厘米深度中伽马污染接近50%。在RENT I中,在用2.5 cm的铅过滤光束后,伽马成分降低到25%,而总剂量率降低到22 rd/min。
The RENT-project: radiobiological results and planned clinical application.
Various preclinical tests have been performed to determine the properties of fast neutrons of a mean energy of 2 MeV produced by an U-235 converter plate in the research reactor of the Technical University of Munich. Experiments have been carried out using two specific beams denoted as RENT I and RENT II (RENT stands for Reaktor Neutron Therapy). RENT II is the unmodified beam with a dose rate of 65 rd/min and a gamma-contamination of nearly 50% in 2 cm depth of a perspex phantom. In RENT I the gamma-component is reduced to 25% after filtration of the beam with 2.5 cm lead, whereas the total dose rate is reduced to 22 rd/min.