基于一致伪影建模的无监督CT金属伪影还原。

IF 7.7 2区 医学 Q1 COMPUTER SCIENCE, INFORMATION SYSTEMS
Enyu Bao, Yifei Chen, Junhao Ye, Xueyan Song, Kasidit Anmahapong, Ziang Wang, Guanyu Zhou, Feiwei Qin, Yaqi Wang, Changmiao Wang, Huiyu Zhou, Qiyuan Tian
{"title":"基于一致伪影建模的无监督CT金属伪影还原。","authors":"Enyu Bao, Yifei Chen, Junhao Ye, Xueyan Song, Kasidit Anmahapong, Ziang Wang, Guanyu Zhou, Feiwei Qin, Yaqi Wang, Changmiao Wang, Huiyu Zhou, Qiyuan Tian","doi":"10.1109/JBHI.2026.3740719","DOIUrl":null,"url":null,"abstract":"<p><p>Metal artifacts severely corrupt CT images, masking anatomical structures and undermining diagnostic reliability. Although supervised metal artifact reduction (MAR) achieves strong suppression, its dependence on paired clean and corrupted data confines it to simulated domains and hinders clinical translation. We recast unsupervised MAR as an artifact-consistent residual learning problem and propose a physically grounded, attention-guided generative framework that closes the loop between artifact estimation and removal. A single-generator dual-branch architecture estimates metal-induced corruption as a transferable additive residual and reinjects it to synthesize controlled degraded samples during cyclic training, explicitly constraining the removable component. Guided by interpolated pseudo-priors, a difference-aware attention mechanism concentrates correction on corrupted regions while safeguarding intact anatomy, all without paired supervision. Extensive experiments on synthetic benchmarks and real clinical data show that our method restores structural fidelity, suppresses streaks and beam-hardening, and generalizes robustly across diverse implants and anatomical sites. Beyond perceptual quality, it delivers state-of-the-art pelvic bone segmentation under metal corruption at efficient inference cost. This work charts an interpretable, efficient, and clinically scalable route toward reliable CT metal artifact suppression in real-world practice. Our source code is available at https://github.com/wonderfulpoet/CAM-Net.</p>","PeriodicalId":13073,"journal":{"name":"IEEE Journal of Biomedical and Health Informatics","volume":"PP ","pages":""},"PeriodicalIF":7.7000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Unsupervised CT Metal Artifact Reduction Via Consistent Artifact Modeling.\",\"authors\":\"Enyu Bao, Yifei Chen, Junhao Ye, Xueyan Song, Kasidit Anmahapong, Ziang Wang, Guanyu Zhou, Feiwei Qin, Yaqi Wang, Changmiao Wang, Huiyu Zhou, Qiyuan Tian\",\"doi\":\"10.1109/JBHI.2026.3740719\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Metal artifacts severely corrupt CT images, masking anatomical structures and undermining diagnostic reliability. Although supervised metal artifact reduction (MAR) achieves strong suppression, its dependence on paired clean and corrupted data confines it to simulated domains and hinders clinical translation. We recast unsupervised MAR as an artifact-consistent residual learning problem and propose a physically grounded, attention-guided generative framework that closes the loop between artifact estimation and removal. A single-generator dual-branch architecture estimates metal-induced corruption as a transferable additive residual and reinjects it to synthesize controlled degraded samples during cyclic training, explicitly constraining the removable component. Guided by interpolated pseudo-priors, a difference-aware attention mechanism concentrates correction on corrupted regions while safeguarding intact anatomy, all without paired supervision. Extensive experiments on synthetic benchmarks and real clinical data show that our method restores structural fidelity, suppresses streaks and beam-hardening, and generalizes robustly across diverse implants and anatomical sites. Beyond perceptual quality, it delivers state-of-the-art pelvic bone segmentation under metal corruption at efficient inference cost. This work charts an interpretable, efficient, and clinically scalable route toward reliable CT metal artifact suppression in real-world practice. Our source code is available at https://github.com/wonderfulpoet/CAM-Net.</p>\",\"PeriodicalId\":13073,\"journal\":{\"name\":\"IEEE Journal of Biomedical and Health Informatics\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":7.7000,\"publicationDate\":\"2026-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Journal of Biomedical and Health Informatics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1109/JBHI.2026.3740719\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"COMPUTER SCIENCE, INFORMATION SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Biomedical and Health Informatics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/JBHI.2026.3740719","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, INFORMATION SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Unsupervised CT Metal Artifact Reduction Via Consistent Artifact Modeling.

Metal artifacts severely corrupt CT images, masking anatomical structures and undermining diagnostic reliability. Although supervised metal artifact reduction (MAR) achieves strong suppression, its dependence on paired clean and corrupted data confines it to simulated domains and hinders clinical translation. We recast unsupervised MAR as an artifact-consistent residual learning problem and propose a physically grounded, attention-guided generative framework that closes the loop between artifact estimation and removal. A single-generator dual-branch architecture estimates metal-induced corruption as a transferable additive residual and reinjects it to synthesize controlled degraded samples during cyclic training, explicitly constraining the removable component. Guided by interpolated pseudo-priors, a difference-aware attention mechanism concentrates correction on corrupted regions while safeguarding intact anatomy, all without paired supervision. Extensive experiments on synthetic benchmarks and real clinical data show that our method restores structural fidelity, suppresses streaks and beam-hardening, and generalizes robustly across diverse implants and anatomical sites. Beyond perceptual quality, it delivers state-of-the-art pelvic bone segmentation under metal corruption at efficient inference cost. This work charts an interpretable, efficient, and clinically scalable route toward reliable CT metal artifact suppression in real-world practice. Our source code is available at https://github.com/wonderfulpoet/CAM-Net.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Journal of Biomedical and Health Informatics
IEEE Journal of Biomedical and Health Informatics COMPUTER SCIENCE, INFORMATION SYSTEMS-COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
CiteScore
13.60
自引率
6.50%
发文量
1151
期刊介绍: IEEE Journal of Biomedical and Health Informatics publishes original papers presenting recent advances where information and communication technologies intersect with health, healthcare, life sciences, and biomedicine. Topics include acquisition, transmission, storage, retrieval, management, and analysis of biomedical and health information. The journal covers applications of information technologies in healthcare, patient monitoring, preventive care, early disease diagnosis, therapy discovery, and personalized treatment protocols. It explores electronic medical and health records, clinical information systems, decision support systems, medical and biological imaging informatics, wearable systems, body area/sensor networks, and more. Integration-related topics like interoperability, evidence-based medicine, and secure patient data are also addressed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书