{"title":"碘造影剂缺乏对重复CT成像和ED显像的影响:回顾性分析。","authors":"Eline M van den Broek-Altenburg, Jamie S Benson, Kristen K DeStigter, Dmitriy Akselrod","doi":"10.1067/j.cpradiol.2026.09.006","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the impact of an iodinated contrast media (ICM) shortage on repeat CT imaging, length of stay (LOS), and total healthcare spending in a mid-sized academic medical center, focusing on abdominal/pelvis CT.</p><p><strong>Methods: </strong>Retrospective cohort analysis of electronic health records from August 1, 2021 to February 15, 2023. Four shortage phases were defined: Pre-Shortage, Wash-In, Rationing, and Post-Shortage. The primary exposure was receipt of CT with contrast vs. CT without contrast at initial imaging. Outcomes included number of follow-up scans per patient, LOS, and total costs within two months after initial imaging. Multivariable models adjusted for age, sex, comorbidities, and ED presentation characteristics to estimate associations between initial contrast status and subsequent imaging, LOS, and costs.</p><p><strong>Results: </strong>Among 12,232 CT encounters, 38-55% of initial scans occurred without contrast during shortage phases. The proportion of patients requiring multiple follow-up scans increased in the shortage periods, with a notable rise during Rationing. Median LOS was longer for patients who had non-contrast initial CT compared with contrast-enhanced CT in the same period. Total peri-imaging costs rose in shortage phases, driven largely by additional imaging and extended LOS. After return to baseline supply, follow-up imaging and LOS metrics approached pre-shortage levels, yet costs remained elevated in the short term.</p><p><strong>Discussion: </strong>The ICM shortage and associated rationing protocols substantially changed contrast use. Contrary to our initial hypothesis, adjusted repeat imaging was lower during rationing than during the pre- and post-shortage periods. When repeat imaging occurred, it was associated with longer outpatient and inpatient LOS. Contrast use and repeat imaging were also associated with differences in billed charges. These findings highlight the importance of evaluating both imaging utilization and downstream resource use during future ICM disruptions.</p>","PeriodicalId":93969,"journal":{"name":"Current problems in diagnostic radiology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of iodinated contrast shortage on repeat CT imaging and ED spending: a retrospective analysis.\",\"authors\":\"Eline M van den Broek-Altenburg, Jamie S Benson, Kristen K DeStigter, Dmitriy Akselrod\",\"doi\":\"10.1067/j.cpradiol.2026.09.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the impact of an iodinated contrast media (ICM) shortage on repeat CT imaging, length of stay (LOS), and total healthcare spending in a mid-sized academic medical center, focusing on abdominal/pelvis CT.</p><p><strong>Methods: </strong>Retrospective cohort analysis of electronic health records from August 1, 2021 to February 15, 2023. Four shortage phases were defined: Pre-Shortage, Wash-In, Rationing, and Post-Shortage. The primary exposure was receipt of CT with contrast vs. CT without contrast at initial imaging. Outcomes included number of follow-up scans per patient, LOS, and total costs within two months after initial imaging. Multivariable models adjusted for age, sex, comorbidities, and ED presentation characteristics to estimate associations between initial contrast status and subsequent imaging, LOS, and costs.</p><p><strong>Results: </strong>Among 12,232 CT encounters, 38-55% of initial scans occurred without contrast during shortage phases. The proportion of patients requiring multiple follow-up scans increased in the shortage periods, with a notable rise during Rationing. Median LOS was longer for patients who had non-contrast initial CT compared with contrast-enhanced CT in the same period. Total peri-imaging costs rose in shortage phases, driven largely by additional imaging and extended LOS. After return to baseline supply, follow-up imaging and LOS metrics approached pre-shortage levels, yet costs remained elevated in the short term.</p><p><strong>Discussion: </strong>The ICM shortage and associated rationing protocols substantially changed contrast use. Contrary to our initial hypothesis, adjusted repeat imaging was lower during rationing than during the pre- and post-shortage periods. When repeat imaging occurred, it was associated with longer outpatient and inpatient LOS. Contrast use and repeat imaging were also associated with differences in billed charges. These findings highlight the importance of evaluating both imaging utilization and downstream resource use during future ICM disruptions.</p>\",\"PeriodicalId\":93969,\"journal\":{\"name\":\"Current problems in diagnostic radiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2026-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current problems in diagnostic radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1067/j.cpradiol.2026.09.006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current problems in diagnostic radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1067/j.cpradiol.2026.09.006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估碘造影剂(ICM)短缺对中型学术医疗中心重复CT成像、住院时间(LOS)和总医疗支出的影响,重点是腹部/骨盆CT。方法:回顾性队列分析2021年8月1日至2023年2月15日的电子健康记录。定义了四个短缺阶段:短缺前、入库、配给和短缺后。最初的暴露是在初始成像时接受有造影剂的CT和没有造影剂的CT。结果包括每位患者的随访扫描次数、LOS和初始成像后两个月内的总费用。多变量模型调整了年龄、性别、合并症和ED表现特征,以估计初始对比状态与后续成像、LOS和成本之间的关系。结果:在12232次CT接触中,38-55%的初始扫描在缺乏阶段没有进行对比。在短缺时期,需要多次随访扫描的患者比例增加,在配给期间显著增加。与同期的增强CT相比,非对比初始CT患者的中位LOS更长。总成像费用在短缺阶段上升,主要是由于额外的成像和延长的LOS。恢复基线供应后,随访成像和LOS指标接近短缺前的水平,但短期内成本仍居高不下。讨论:ICM短缺和相关配给协议实质上改变了对比度的使用。与我们最初的假设相反,在配给期间,调整后的重复成像比短缺前后时期低。当重复成像发生时,它与较长的门诊和住院LOS有关。对比使用和重复成像也与账单费用的差异有关。这些发现强调了在未来ICM中断期间评估成像利用和下游资源利用的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of iodinated contrast shortage on repeat CT imaging and ED spending: a retrospective analysis.

Objective: To evaluate the impact of an iodinated contrast media (ICM) shortage on repeat CT imaging, length of stay (LOS), and total healthcare spending in a mid-sized academic medical center, focusing on abdominal/pelvis CT.

Methods: Retrospective cohort analysis of electronic health records from August 1, 2021 to February 15, 2023. Four shortage phases were defined: Pre-Shortage, Wash-In, Rationing, and Post-Shortage. The primary exposure was receipt of CT with contrast vs. CT without contrast at initial imaging. Outcomes included number of follow-up scans per patient, LOS, and total costs within two months after initial imaging. Multivariable models adjusted for age, sex, comorbidities, and ED presentation characteristics to estimate associations between initial contrast status and subsequent imaging, LOS, and costs.

Results: Among 12,232 CT encounters, 38-55% of initial scans occurred without contrast during shortage phases. The proportion of patients requiring multiple follow-up scans increased in the shortage periods, with a notable rise during Rationing. Median LOS was longer for patients who had non-contrast initial CT compared with contrast-enhanced CT in the same period. Total peri-imaging costs rose in shortage phases, driven largely by additional imaging and extended LOS. After return to baseline supply, follow-up imaging and LOS metrics approached pre-shortage levels, yet costs remained elevated in the short term.

Discussion: The ICM shortage and associated rationing protocols substantially changed contrast use. Contrary to our initial hypothesis, adjusted repeat imaging was lower during rationing than during the pre- and post-shortage periods. When repeat imaging occurred, it was associated with longer outpatient and inpatient LOS. Contrast use and repeat imaging were also associated with differences in billed charges. These findings highlight the importance of evaluating both imaging utilization and downstream resource use during future ICM disruptions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书