利用混合现实将病理数据与肿瘤床对齐的基于手术夹的注册方法。

Richie Dix, Mays Neiroukh, Bowen Xiang, Jie Ying Wu, Michael C Topf, Ingrid M Meszoely, Jon S Heiselman, Michael I Miga
{"title":"利用混合现实将病理数据与肿瘤床对齐的基于手术夹的注册方法。","authors":"Richie Dix, Mays Neiroukh, Bowen Xiang, Jie Ying Wu, Michael C Topf, Ingrid M Meszoely, Jon S Heiselman, Michael I Miga","doi":"10.1117/12.3087843","DOIUrl":null,"url":null,"abstract":"<p><p>During tumor resections, surgeons must integrate visual cues from the operative field with feedback from pathology to evaluate resection margins. This process requires constructing a complex mental spatial map of the tumor bed and the ability to integrate pathological analysis back for additional resections. Unfortunately, this can lead to incomplete resections and result in positive margins. Such outcomes often necessitate additional surgeries, increasing patient risk, anxiety, and overall healthcare burden. To address this challenge, we are investigating a mixed reality (MR) system that transforms pathology-confirmed positive margins directly to locations within the surgical field. A critical requirement of this system is accurate alignment of pathology data with the intraoperative presentation of the tumor bed. We present and evaluate a registration workflow that employs surgical clips placed on both resection specimens and corresponding tumor bed sites as corresponding fiducial markers. Data acquisition was performed using the Microsoft HoloLens<sup>®</sup> 2 enabled to track a conventional stylus fitted with conventional retroreflective spheres. Voice commands were incorporated to streamline point collection and registration. System point acquisition accuracy and precision were assessed using a machined phantom containing nine fiducial points, each with a known ground truth and positioned throughout the field of view. Precision was measured from the point distribution of repetitive acquisition, while accuracy was evaluated by registering collected data to ground-truth coordinates. To investigate our MR approach within the desired clinical context, a second soft tissue-like breast phantom was created to simulate a mock resection. Conventional surgical clips used in surgical practice were used as fiducial markers, and target points within the mock resection site were created using a process that ensured known correspondence between the mock specimen and the tumor-bed. It should be noted that in this preliminary realization, rigid alignment approaches were used. Ground truth comparisons were independently captured using a second optical tracker. Following rigid registration, specimen targets were projected into the phantom cavity using the HoloLens<sup>®</sup> 2 and compared against the ground truth. The point acquisition precision yielded a fiducial localization error (FLE) of 0.7 ± 0.2 mm. When registering to the ground-truth machined phantom, the fiducial registration error (FRE) was 1.8 ± 0.6 mm and the target registration error (TRE) was 2.6 ± 0.9 mm. With respect to the mock clinical scenario, the deep-margin gold-standard alignment error using the conventional optical tracker yielded an FRE of 2.8 ± 1.0 mm with a mean TRE of 3.3 ± 1.7 mm. When performing the same experiment using HoloLens<sup>®</sup> 2 internal tracking, the composite mean FRE increased to 3.8 ± 0.8 mm and the composite mean TRE increased to 5.3 ± 1.1mm. Overall, the fidelity of the results is quite encouraging, but they also suggest that there is some performance decrease when using the HoloLens<sup>®</sup> 2 for localization rather than the conventional optical tracking devices.</p>","PeriodicalId":74505,"journal":{"name":"Proceedings of SPIE--the International Society for Optical Engineering","volume":"13927 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13479359/pdf/","citationCount":"0","resultStr":"{\"title\":\"Toward a Surgical Clip-Based Registration Approach for Aligning Pathology Data to Tumor Bed Using Mixed Reality.\",\"authors\":\"Richie Dix, Mays Neiroukh, Bowen Xiang, Jie Ying Wu, Michael C Topf, Ingrid M Meszoely, Jon S Heiselman, Michael I Miga\",\"doi\":\"10.1117/12.3087843\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>During tumor resections, surgeons must integrate visual cues from the operative field with feedback from pathology to evaluate resection margins. This process requires constructing a complex mental spatial map of the tumor bed and the ability to integrate pathological analysis back for additional resections. Unfortunately, this can lead to incomplete resections and result in positive margins. Such outcomes often necessitate additional surgeries, increasing patient risk, anxiety, and overall healthcare burden. To address this challenge, we are investigating a mixed reality (MR) system that transforms pathology-confirmed positive margins directly to locations within the surgical field. A critical requirement of this system is accurate alignment of pathology data with the intraoperative presentation of the tumor bed. We present and evaluate a registration workflow that employs surgical clips placed on both resection specimens and corresponding tumor bed sites as corresponding fiducial markers. Data acquisition was performed using the Microsoft HoloLens<sup>®</sup> 2 enabled to track a conventional stylus fitted with conventional retroreflective spheres. Voice commands were incorporated to streamline point collection and registration. System point acquisition accuracy and precision were assessed using a machined phantom containing nine fiducial points, each with a known ground truth and positioned throughout the field of view. Precision was measured from the point distribution of repetitive acquisition, while accuracy was evaluated by registering collected data to ground-truth coordinates. To investigate our MR approach within the desired clinical context, a second soft tissue-like breast phantom was created to simulate a mock resection. Conventional surgical clips used in surgical practice were used as fiducial markers, and target points within the mock resection site were created using a process that ensured known correspondence between the mock specimen and the tumor-bed. It should be noted that in this preliminary realization, rigid alignment approaches were used. Ground truth comparisons were independently captured using a second optical tracker. Following rigid registration, specimen targets were projected into the phantom cavity using the HoloLens<sup>®</sup> 2 and compared against the ground truth. The point acquisition precision yielded a fiducial localization error (FLE) of 0.7 ± 0.2 mm. When registering to the ground-truth machined phantom, the fiducial registration error (FRE) was 1.8 ± 0.6 mm and the target registration error (TRE) was 2.6 ± 0.9 mm. With respect to the mock clinical scenario, the deep-margin gold-standard alignment error using the conventional optical tracker yielded an FRE of 2.8 ± 1.0 mm with a mean TRE of 3.3 ± 1.7 mm. When performing the same experiment using HoloLens<sup>®</sup> 2 internal tracking, the composite mean FRE increased to 3.8 ± 0.8 mm and the composite mean TRE increased to 5.3 ± 1.1mm. Overall, the fidelity of the results is quite encouraging, but they also suggest that there is some performance decrease when using the HoloLens<sup>®</sup> 2 for localization rather than the conventional optical tracking devices.</p>\",\"PeriodicalId\":74505,\"journal\":{\"name\":\"Proceedings of SPIE--the International Society for Optical Engineering\",\"volume\":\"13927 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2026-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13479359/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of SPIE--the International Society for Optical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.3087843\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/4/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of SPIE--the International Society for Optical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.3087843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在肿瘤切除过程中,外科医生必须将手术野的视觉线索与病理反馈结合起来评估切除边缘。这个过程需要构建一个复杂的肿瘤床的心理空间图和整合病理分析的能力,以进行额外的切除。不幸的是,这可能导致不完全切除并导致正切缘。这样的结果往往需要额外的手术,增加患者的风险、焦虑和整体医疗负担。为了应对这一挑战,我们正在研究一种混合现实(MR)系统,该系统将病理证实的阳性边缘直接转换为手术野内的位置。该系统的一个关键要求是准确地将病理数据与术中肿瘤床的表现结合起来。我们提出并评估了一种注册工作流程,该流程采用手术夹放置在切除标本和相应的肿瘤床上作为相应的基准标记。使用Microsoft HoloLens®2进行数据采集,该HoloLens®2能够跟踪装有传统反光球的传统触控笔。语音命令被纳入以简化积分收集和登记。使用包含9个基准点的机械模型来评估系统点采集的准确性和精度,每个基准点都有一个已知的地面真实值,并定位在整个视野中。从重复采集的点分布来衡量精度,而通过将收集到的数据注册到地面真值坐标来评估精度。为了在理想的临床环境下研究我们的MR方法,我们创建了第二个软组织样的乳房假体来模拟模拟切除。手术实践中使用的常规手术夹作为基准标记,使用确保模拟标本和肿瘤床之间已知对应关系的过程创建模拟切除部位内的目标点。应该指出的是,在这个初步实现中,使用了刚性对齐方法。地面真值比较是使用第二个光学跟踪器独立捕获的。在刚性配准后,使用HoloLens®2将样本目标投射到幻腔中,并与地面真实情况进行比较。点采集精度的基准定位误差(FLE)为0.7±0.2 mm。配准时,基准配准误差(FRE)为1.8±0.6 mm,目标配准误差(TRE)为2.6±0.9 mm。对于模拟临床场景,使用传统光学跟踪器的深缘金标准对准误差产生的FRE为2.8±1.0 mm,平均TRE为3.3±1.7 mm。使用HoloLens®2内部跟踪进行相同实验时,复合平均FRE增加到3.8±0.8 mm,复合平均TRE增加到5.3±1.1mm。总体而言,结果的保真度相当令人鼓舞,但它们也表明,使用HoloLens®2进行定位而不是使用传统的光学跟踪设备时,性能会有所下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Toward a Surgical Clip-Based Registration Approach for Aligning Pathology Data to Tumor Bed Using Mixed Reality.

During tumor resections, surgeons must integrate visual cues from the operative field with feedback from pathology to evaluate resection margins. This process requires constructing a complex mental spatial map of the tumor bed and the ability to integrate pathological analysis back for additional resections. Unfortunately, this can lead to incomplete resections and result in positive margins. Such outcomes often necessitate additional surgeries, increasing patient risk, anxiety, and overall healthcare burden. To address this challenge, we are investigating a mixed reality (MR) system that transforms pathology-confirmed positive margins directly to locations within the surgical field. A critical requirement of this system is accurate alignment of pathology data with the intraoperative presentation of the tumor bed. We present and evaluate a registration workflow that employs surgical clips placed on both resection specimens and corresponding tumor bed sites as corresponding fiducial markers. Data acquisition was performed using the Microsoft HoloLens® 2 enabled to track a conventional stylus fitted with conventional retroreflective spheres. Voice commands were incorporated to streamline point collection and registration. System point acquisition accuracy and precision were assessed using a machined phantom containing nine fiducial points, each with a known ground truth and positioned throughout the field of view. Precision was measured from the point distribution of repetitive acquisition, while accuracy was evaluated by registering collected data to ground-truth coordinates. To investigate our MR approach within the desired clinical context, a second soft tissue-like breast phantom was created to simulate a mock resection. Conventional surgical clips used in surgical practice were used as fiducial markers, and target points within the mock resection site were created using a process that ensured known correspondence between the mock specimen and the tumor-bed. It should be noted that in this preliminary realization, rigid alignment approaches were used. Ground truth comparisons were independently captured using a second optical tracker. Following rigid registration, specimen targets were projected into the phantom cavity using the HoloLens® 2 and compared against the ground truth. The point acquisition precision yielded a fiducial localization error (FLE) of 0.7 ± 0.2 mm. When registering to the ground-truth machined phantom, the fiducial registration error (FRE) was 1.8 ± 0.6 mm and the target registration error (TRE) was 2.6 ± 0.9 mm. With respect to the mock clinical scenario, the deep-margin gold-standard alignment error using the conventional optical tracker yielded an FRE of 2.8 ± 1.0 mm with a mean TRE of 3.3 ± 1.7 mm. When performing the same experiment using HoloLens® 2 internal tracking, the composite mean FRE increased to 3.8 ± 0.8 mm and the composite mean TRE increased to 5.3 ± 1.1mm. Overall, the fidelity of the results is quite encouraging, but they also suggest that there is some performance decrease when using the HoloLens® 2 for localization rather than the conventional optical tracking devices.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书