{"title":"缝合带与金属丝联合空心螺钉张力带固定髌骨横向骨折的生物力学评价:生物力学研究。","authors":"Michael C LaRoque, Alexander C M Chong, Bruce E Piatt","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transverse patella fractures requiring surgical fixation are typically treated with a tension band construct using metal wire. This technique is associated with high rates of complications and reoperation. Alternative fixation technique utilizing non-absorbable suture materials have been introduced. This biomechanical study aims to compare the stability of two tension band constructs, both utilizing headed cannulated lag screws, with either suture tape or traditional metal wire under cyclic load conditions, simulating repetitive physiological stress.</p><p><strong>Methods: </strong>Six matched pairs of fresh frozen cadaveric knees were obtained for testing. A standardized transverse patellar osteotomy (AO/OTA 34C1.1) was created in each to simulate a simple transverse patella fracture. Each pair was repaired using a tension band construct with headed cannulated screws, randomized to fixation with either suture tape or metal wire. All specimens underwent cyclic loading from 0 to 90 knee flexion at a frequency of 0.2 Hz for up to 1000 cycles. Two displacement transducers were used to measure real-time fracture gap displacement during testing from the start of testing and until clinical fixation failure. Clinical failure is defined as fracture gap displacement > 3 mm.</p><p><strong>Results: </strong>Clinical failure occurred in 5 of 6 specimens (83%) in the suture tape group, with a mean of 296±433 cycles. In the metal wire group, 4 of 6 specimens (67%) experienced clinical failure, with a mean of 421±461 cycles. There was no statistically significant difference in cycles to failure between the two groups (p=0.29). Kaplan-Meier survival analysis demonstrated a 500-cycle survival rate of 33% (95% CI: 0%-71%) for both groups.</p><p><strong>Conclusion: </strong>Both constructs may be considered viable options for the surgical treatment of simple transverse patella fractures.</p><p><strong>Level of evidence: </strong>V.</p>","PeriodicalId":94233,"journal":{"name":"The Iowa orthopaedic journal","volume":"46 1","pages":"223-230"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13389598/pdf/","citationCount":"0","resultStr":"{\"title\":\"Biomechanical Evaluation of Suture Tape Versus Metallic Wire With Cannulated Screws Tension Band Fixation For Transverse Patella Fractures: A Biomechanical Study.\",\"authors\":\"Michael C LaRoque, Alexander C M Chong, Bruce E Piatt\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Transverse patella fractures requiring surgical fixation are typically treated with a tension band construct using metal wire. This technique is associated with high rates of complications and reoperation. Alternative fixation technique utilizing non-absorbable suture materials have been introduced. This biomechanical study aims to compare the stability of two tension band constructs, both utilizing headed cannulated lag screws, with either suture tape or traditional metal wire under cyclic load conditions, simulating repetitive physiological stress.</p><p><strong>Methods: </strong>Six matched pairs of fresh frozen cadaveric knees were obtained for testing. A standardized transverse patellar osteotomy (AO/OTA 34C1.1) was created in each to simulate a simple transverse patella fracture. Each pair was repaired using a tension band construct with headed cannulated screws, randomized to fixation with either suture tape or metal wire. All specimens underwent cyclic loading from 0 to 90 knee flexion at a frequency of 0.2 Hz for up to 1000 cycles. Two displacement transducers were used to measure real-time fracture gap displacement during testing from the start of testing and until clinical fixation failure. Clinical failure is defined as fracture gap displacement > 3 mm.</p><p><strong>Results: </strong>Clinical failure occurred in 5 of 6 specimens (83%) in the suture tape group, with a mean of 296±433 cycles. In the metal wire group, 4 of 6 specimens (67%) experienced clinical failure, with a mean of 421±461 cycles. There was no statistically significant difference in cycles to failure between the two groups (p=0.29). Kaplan-Meier survival analysis demonstrated a 500-cycle survival rate of 33% (95% CI: 0%-71%) for both groups.</p><p><strong>Conclusion: </strong>Both constructs may be considered viable options for the surgical treatment of simple transverse patella fractures.</p><p><strong>Level of evidence: </strong>V.</p>\",\"PeriodicalId\":94233,\"journal\":{\"name\":\"The Iowa orthopaedic journal\",\"volume\":\"46 1\",\"pages\":\"223-230\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2026-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13389598/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Iowa orthopaedic journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Iowa orthopaedic journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:需要手术固定的横向髌骨骨折通常使用金属丝张力带进行治疗。该技术与高并发症和再手术率相关。介绍了利用不可吸收缝线材料的替代固定技术。本生物力学研究旨在比较两种张力带结构在循环载荷条件下的稳定性,这两种张力带都是使用空心螺钉,无论是缝合带还是传统金属丝,模拟重复的生理应力。方法:取6对匹配的新鲜冷冻尸体膝关节进行试验。采用标准化髌骨横截骨术(AO/OTA 34C1.1)模拟单纯性髌骨横截骨折。使用带头空心螺钉的张力带结构修复每一对,随机选择缝合带或金属丝固定。所有的标本都经历了从0到90次膝盖弯曲的循环加载,频率为0.2 Hz,最多1000次循环。两个位移传感器用于测量从测试开始到临床固定失败期间的实时骨折间隙位移。结果:缝合带组6例标本中有5例(83%)出现临床失败,平均296±433个周期。金属丝组6例患者中有4例(67%)出现临床失败,平均421±461周期。两组患者的失败周期差异无统计学意义(p=0.29)。Kaplan-Meier生存分析显示,两组患者500个周期的生存率均为33% (95% CI: 0%-71%)。结论:对于单纯性横髌骨骨折的手术治疗,这两种结构都是可行的选择。证据等级:V。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biomechanical Evaluation of Suture Tape Versus Metallic Wire With Cannulated Screws Tension Band Fixation For Transverse Patella Fractures: A Biomechanical Study.

Background: Transverse patella fractures requiring surgical fixation are typically treated with a tension band construct using metal wire. This technique is associated with high rates of complications and reoperation. Alternative fixation technique utilizing non-absorbable suture materials have been introduced. This biomechanical study aims to compare the stability of two tension band constructs, both utilizing headed cannulated lag screws, with either suture tape or traditional metal wire under cyclic load conditions, simulating repetitive physiological stress.

Methods: Six matched pairs of fresh frozen cadaveric knees were obtained for testing. A standardized transverse patellar osteotomy (AO/OTA 34C1.1) was created in each to simulate a simple transverse patella fracture. Each pair was repaired using a tension band construct with headed cannulated screws, randomized to fixation with either suture tape or metal wire. All specimens underwent cyclic loading from 0 to 90 knee flexion at a frequency of 0.2 Hz for up to 1000 cycles. Two displacement transducers were used to measure real-time fracture gap displacement during testing from the start of testing and until clinical fixation failure. Clinical failure is defined as fracture gap displacement > 3 mm.

Results: Clinical failure occurred in 5 of 6 specimens (83%) in the suture tape group, with a mean of 296±433 cycles. In the metal wire group, 4 of 6 specimens (67%) experienced clinical failure, with a mean of 421±461 cycles. There was no statistically significant difference in cycles to failure between the two groups (p=0.29). Kaplan-Meier survival analysis demonstrated a 500-cycle survival rate of 33% (95% CI: 0%-71%) for both groups.

Conclusion: Both constructs may be considered viable options for the surgical treatment of simple transverse patella fractures.

Level of evidence: V.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书