一种可穿戴的基于纸张的贴片,集成渗透汗液提取和差分传感,用于帕金森病的L -多巴连续监测

Z Y Chen, Yu Cai, Shanshan Zhang, Yue Zhou, Yiming Wei, Junhao Li, Rong Xu, Yunbo Gai, Xuesong Ye, Congcong Zhou, Bo Liang
{"title":"一种可穿戴的基于纸张的贴片,集成渗透汗液提取和差分传感,用于帕金森病的L -多巴连续监测","authors":"Z Y Chen, Yu Cai, Shanshan Zhang, Yue Zhou, Yiming Wei, Junhao Li, Rong Xu, Yunbo Gai, Xuesong Ye, Congcong Zhou, Bo Liang","doi":"10.1002/admt.71086","DOIUrl":null,"url":null,"abstract":"ABSTRACT Levodopa (L‐Dopa) pharmacokinetic monitoring is crucial for optimizing therapy in Parkinson's disease (PD); however, existing sweat sensors are still limited by their reliance on active perspiration and poor specificity in complex biofluids. Here, we present a passive osmotic differential electrochemical (PODE) patch for continuous, non‐invasive L‐Dopa monitoring under resting conditions. The patch employs an ethylene glycol‐loaded polyacrylamide/polyvinyl alcohol (PAAm/PVA) hydrogel as a “chemical osmotic pump” to drive sweat transport without external power or physical exertion. For sensitive detection, a three‐dimensional paper‐based electrode is constructed via in situ growth of acrylamide‐doped poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and gold nanoparticles (AuNPs). To eliminate interferences from uric acid (UA) and ascorbic acid (AA), a tyrosinase‐enabled dual‐channel differential sensing strategy is employed. The sensor exhibits a wide linear range and maintains high selectivity in complex artificial sweat. By seamlessly integrating passive sampling with interference‐rejecting electrochemical detection, this flexible, low‐cost patch offers a practical and user‐friendly platform for personalized, at‐home management of PD.","PeriodicalId":7200,"journal":{"name":"Advanced Materials & Technologies","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Wearable Paper‐Based Patch Integrating Osmotic Sweat Extraction and Differential Sensing for Continuous L‐Dopa Monitoring in Parkinson's Disease\",\"authors\":\"Z Y Chen, Yu Cai, Shanshan Zhang, Yue Zhou, Yiming Wei, Junhao Li, Rong Xu, Yunbo Gai, Xuesong Ye, Congcong Zhou, Bo Liang\",\"doi\":\"10.1002/admt.71086\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Levodopa (L‐Dopa) pharmacokinetic monitoring is crucial for optimizing therapy in Parkinson's disease (PD); however, existing sweat sensors are still limited by their reliance on active perspiration and poor specificity in complex biofluids. Here, we present a passive osmotic differential electrochemical (PODE) patch for continuous, non‐invasive L‐Dopa monitoring under resting conditions. The patch employs an ethylene glycol‐loaded polyacrylamide/polyvinyl alcohol (PAAm/PVA) hydrogel as a “chemical osmotic pump” to drive sweat transport without external power or physical exertion. For sensitive detection, a three‐dimensional paper‐based electrode is constructed via in situ growth of acrylamide‐doped poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and gold nanoparticles (AuNPs). To eliminate interferences from uric acid (UA) and ascorbic acid (AA), a tyrosinase‐enabled dual‐channel differential sensing strategy is employed. The sensor exhibits a wide linear range and maintains high selectivity in complex artificial sweat. By seamlessly integrating passive sampling with interference‐rejecting electrochemical detection, this flexible, low‐cost patch offers a practical and user‐friendly platform for personalized, at‐home management of PD.\",\"PeriodicalId\":7200,\"journal\":{\"name\":\"Advanced Materials & Technologies\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2026-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Materials & Technologies\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.1002/admt.71086\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Materials & Technologies","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.1002/admt.71086","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

左旋多巴(L‐Dopa)药代动力学监测对优化帕金森病(PD)治疗至关重要;然而,现有的汗液传感器仍然受到其对活跃汗液的依赖和复杂生物体液特异性差的限制。在这里,我们提出了一种被动渗透差分电化学(PODE)贴片,用于在静息条件下连续、无创地监测左多巴。该贴片采用装载乙二醇的聚丙烯酰胺/聚乙烯醇(PAAm/PVA)水凝胶作为“化学渗透泵”,无需外部电源或体力消耗即可驱动汗液输送。为了进行灵敏的检测,通过原位生长丙烯酰胺掺杂的聚(3,4 -乙烯二氧噻吩)、聚苯乙烯磺酸盐(PEDOT:PSS)和金纳米颗粒(AuNPs)构建了三维纸基电极。为了消除尿酸(UA)和抗坏血酸(AA)的干扰,采用酪氨酸酶激活的双通道差分传感策略。该传感器具有较宽的线性范围,在复杂的人工汗液中保持较高的选择性。通过将被动采样与抗干扰电化学检测无缝集成,这种灵活、低成本的贴片为个性化、在家管理PD提供了一个实用且用户友好的平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Wearable Paper‐Based Patch Integrating Osmotic Sweat Extraction and Differential Sensing for Continuous L‐Dopa Monitoring in Parkinson's Disease
ABSTRACT Levodopa (L‐Dopa) pharmacokinetic monitoring is crucial for optimizing therapy in Parkinson's disease (PD); however, existing sweat sensors are still limited by their reliance on active perspiration and poor specificity in complex biofluids. Here, we present a passive osmotic differential electrochemical (PODE) patch for continuous, non‐invasive L‐Dopa monitoring under resting conditions. The patch employs an ethylene glycol‐loaded polyacrylamide/polyvinyl alcohol (PAAm/PVA) hydrogel as a “chemical osmotic pump” to drive sweat transport without external power or physical exertion. For sensitive detection, a three‐dimensional paper‐based electrode is constructed via in situ growth of acrylamide‐doped poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and gold nanoparticles (AuNPs). To eliminate interferences from uric acid (UA) and ascorbic acid (AA), a tyrosinase‐enabled dual‐channel differential sensing strategy is employed. The sensor exhibits a wide linear range and maintains high selectivity in complex artificial sweat. By seamlessly integrating passive sampling with interference‐rejecting electrochemical detection, this flexible, low‐cost patch offers a practical and user‐friendly platform for personalized, at‐home management of PD.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书