{"title":"具有平衡检测和任意泵极化的振镜扫描瞬态相显微镜。","authors":"Cameron N Coleal, Randy A Bartels, Jesse W Wilson","doi":"10.1364/josab.582227","DOIUrl":null,"url":null,"abstract":"<p><p>Transient absorption microscopy measures excited-state kinetics based on the imaginary part of the pump-induced perturbation to the complex refractive index, i.e. <math><mrow><mi>ℑ</mi> <mrow><mo>{</mo> <mrow><mtext>Δ</mtext> <mi>𝒩</mi></mrow> <mo>}</mo></mrow> </mrow> </math> , with applications in both materials and biomedical sciences. Its complement, transient phase microscopy, enabled by stable inline birefringent interferometry, measures the real part <math><mrow><mi>ℜ</mi> <mrow><mo>{</mo> <mrow><mtext>Δ</mtext> <mi>𝒩</mi></mrow> <mo>}</mo></mrow> </mrow> </math> . The ability to switch between absorption and phase measurements may yield a stronger signal, depending on the sample and probe wavelength. To date, however, transient phase has not been coupled with galvanometer scanners, thus limiting it to materials science applications and non-imaging spectroscopy. Here, we extend transient phase microscopy to operate in a galvanometer-scanning microscope with balanced detection, comparing amplitude and phase measurements in graphene (in which amplitude detection has the advantage), hemoglobin and red blood cells (in which phase detection has the advantage). We examine the impacts and limitations introduced by galvanometer scanning, in addition to relocation of the pump-probe combining dichroic to permit arbitrary polarization of the pump.</p>","PeriodicalId":17280,"journal":{"name":"Journal of The Optical Society of America B-optical Physics","volume":"43 4","pages":"714-723"},"PeriodicalIF":1.9000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13229546/pdf/","citationCount":"0","resultStr":"{\"title\":\"Galvanometer-scanning transient phase microscopy with balanced detection and arbitrary pump polarization.\",\"authors\":\"Cameron N Coleal, Randy A Bartels, Jesse W Wilson\",\"doi\":\"10.1364/josab.582227\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transient absorption microscopy measures excited-state kinetics based on the imaginary part of the pump-induced perturbation to the complex refractive index, i.e. <math><mrow><mi>ℑ</mi> <mrow><mo>{</mo> <mrow><mtext>Δ</mtext> <mi>𝒩</mi></mrow> <mo>}</mo></mrow> </mrow> </math> , with applications in both materials and biomedical sciences. Its complement, transient phase microscopy, enabled by stable inline birefringent interferometry, measures the real part <math><mrow><mi>ℜ</mi> <mrow><mo>{</mo> <mrow><mtext>Δ</mtext> <mi>𝒩</mi></mrow> <mo>}</mo></mrow> </mrow> </math> . The ability to switch between absorption and phase measurements may yield a stronger signal, depending on the sample and probe wavelength. To date, however, transient phase has not been coupled with galvanometer scanners, thus limiting it to materials science applications and non-imaging spectroscopy. Here, we extend transient phase microscopy to operate in a galvanometer-scanning microscope with balanced detection, comparing amplitude and phase measurements in graphene (in which amplitude detection has the advantage), hemoglobin and red blood cells (in which phase detection has the advantage). We examine the impacts and limitations introduced by galvanometer scanning, in addition to relocation of the pump-probe combining dichroic to permit arbitrary polarization of the pump.</p>\",\"PeriodicalId\":17280,\"journal\":{\"name\":\"Journal of The Optical Society of America B-optical Physics\",\"volume\":\"43 4\",\"pages\":\"714-723\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2026-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13229546/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Optical Society of America B-optical Physics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1364/josab.582227\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/3/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Optical Society of America B-optical Physics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/josab.582227","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0
摘要
瞬态吸收显微镜测量基于泵诱导的复折射率扰动的虚部的激激态动力学,即 Δ},在材料和生物医学科学中都有应用。它的补充,瞬态相显微镜,由稳定的内联双折射干涉术实现,测量实部μ l {Δ}。根据样品和探针波长的不同,在吸收和相位测量之间切换的能力可能产生更强的信号。然而,到目前为止,瞬态相位还没有与振镜扫描仪相结合,因此将其限制在材料科学应用和非成像光谱。在这里,我们将瞬态相显微镜扩展到具有平衡检测的振镜扫描显微镜中,比较石墨烯(振幅检测具有优势)、血红蛋白和红细胞(相位检测具有优势)的振幅和相位测量。我们研究了振镜扫描带来的影响和局限性,以及泵-探针结合二色性的重新定位,以允许泵的任意极化。
Galvanometer-scanning transient phase microscopy with balanced detection and arbitrary pump polarization.
Transient absorption microscopy measures excited-state kinetics based on the imaginary part of the pump-induced perturbation to the complex refractive index, i.e. , with applications in both materials and biomedical sciences. Its complement, transient phase microscopy, enabled by stable inline birefringent interferometry, measures the real part . The ability to switch between absorption and phase measurements may yield a stronger signal, depending on the sample and probe wavelength. To date, however, transient phase has not been coupled with galvanometer scanners, thus limiting it to materials science applications and non-imaging spectroscopy. Here, we extend transient phase microscopy to operate in a galvanometer-scanning microscope with balanced detection, comparing amplitude and phase measurements in graphene (in which amplitude detection has the advantage), hemoglobin and red blood cells (in which phase detection has the advantage). We examine the impacts and limitations introduced by galvanometer scanning, in addition to relocation of the pump-probe combining dichroic to permit arbitrary polarization of the pump.
期刊介绍:
The Journal of the Optical Society of America B (JOSA B) is a general optics research journal that complements JOSA A. It emphasizes scientific research on the fundamentals of the interaction of light with matter such as quantum optics, nonlinear optics, and laser physics. Topics include:
Advanced Instrumentation and Measurements
Fiber Optics and Fiber Lasers
Lasers and Other Light Sources from THz to XUV
Light-Induced Phenomena
Nonlinear and High Field Optics
Optical Materials
Optics Modes and Structured Light
Optomechanics
Metamaterials
Nanomaterials
Photonics and Semiconductor Optics
Physical Optics
Plasmonics
Quantum Optics and Entanglement
Quantum Key Distribution
Spectroscopy and Atomic or Molecular Optics
Superresolution and Advanced Imaging
Surface Optics
Ultrafast Optical Phenomena
Wave Guiding and Optical Confinement
JOSA B considers original research articles, feature issue contributions, invited reviews and tutorials, and comments on published articles.