视锥光图作为视网膜偏心的功能。

IF 2.1 4区 物理与天体物理 Q2 OPTICS
Photonics Pub Date : 2025-07-01 Epub Date: 2025-07-04 DOI:10.3390/photonics12070676
Raymond L Warner, Peiluo Xu, David H Brainard, Jessica I W Morgan
{"title":"视锥光图作为视网膜偏心的功能。","authors":"Raymond L Warner, Peiluo Xu, David H Brainard, Jessica I W Morgan","doi":"10.3390/photonics12070676","DOIUrl":null,"url":null,"abstract":"<p><p>Adaptive optics scanning laser ophthalmoscopy optoretinography quantifies cellular function in the living retina by measuring the <i>en face</i> intensity change in cone photoreceptors due to visual stimulation. To fulfill the potential of optoretinography as a biomarker for assessing function in disease, we require normative optoretinographic measurements across the retina. Here we provide such measurements. We use a custom adaptive optics scanning laser ophthalmoscope to investigate cone optoretinogram (ORG) amplitudes across retinal eccentricity in five normal-sighted participants. For this purpose, we aggregated signals across cones in each measurement (~1° by 1° patch) to provide a measurement we call the population ORG. Average population ORG amplitudes decreased with increasing eccentricity for all participants, although there were individual differences in the detailed pattern of the decrease. ORG amplitudes were correlated with the thickness of the outer retina as measured using clinical OCT, which also decreases with eccentricity. Characterizing the population cone ORG as a function of eccentricity in normal-sighted participants is an important step towards establishing norms that will allow it to be used as a biomarker for assessing photoreceptor function in retinal disease.</p>","PeriodicalId":20154,"journal":{"name":"Photonics","volume":"12 7","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12981616/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Cone Optoretinogram as a Function of Retinal Eccentricity.\",\"authors\":\"Raymond L Warner, Peiluo Xu, David H Brainard, Jessica I W Morgan\",\"doi\":\"10.3390/photonics12070676\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Adaptive optics scanning laser ophthalmoscopy optoretinography quantifies cellular function in the living retina by measuring the <i>en face</i> intensity change in cone photoreceptors due to visual stimulation. To fulfill the potential of optoretinography as a biomarker for assessing function in disease, we require normative optoretinographic measurements across the retina. Here we provide such measurements. We use a custom adaptive optics scanning laser ophthalmoscope to investigate cone optoretinogram (ORG) amplitudes across retinal eccentricity in five normal-sighted participants. For this purpose, we aggregated signals across cones in each measurement (~1° by 1° patch) to provide a measurement we call the population ORG. Average population ORG amplitudes decreased with increasing eccentricity for all participants, although there were individual differences in the detailed pattern of the decrease. ORG amplitudes were correlated with the thickness of the outer retina as measured using clinical OCT, which also decreases with eccentricity. Characterizing the population cone ORG as a function of eccentricity in normal-sighted participants is an important step towards establishing norms that will allow it to be used as a biomarker for assessing photoreceptor function in retinal disease.</p>\",\"PeriodicalId\":20154,\"journal\":{\"name\":\"Photonics\",\"volume\":\"12 7\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12981616/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photonics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.3390/photonics12070676\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/7/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photonics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.3390/photonics12070676","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

摘要

自适应光学扫描激光检眼镜视网膜造影通过测量视锥光感受器在视觉刺激下的表面强度变化来量化活视网膜的细胞功能。为了实现视光成像作为评估疾病功能的生物标志物的潜力,我们需要规范的视网膜视光成像测量。这里我们提供这样的测量。我们使用定制的自适应光学扫描激光检眼镜来研究五名正常视力参与者的视网膜偏心率锥体视网膜图(ORG)振幅。为此,我们在每个测量(~1°× 1°patch)中聚合锥体上的信号,以提供我们称为种群ORG的测量。所有参与者的平均总体ORG振幅随着偏心率的增加而下降,尽管在下降的详细模式上存在个体差异。ORG振幅与临床OCT测量的外视网膜厚度相关,外视网膜厚度也随偏心减小。将人群锥体ORG描述为正常视力参与者的偏心率函数是建立规范的重要一步,这将使其成为评估视网膜疾病中光感受器功能的生物标志物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Cone Optoretinogram as a Function of Retinal Eccentricity.

Adaptive optics scanning laser ophthalmoscopy optoretinography quantifies cellular function in the living retina by measuring the en face intensity change in cone photoreceptors due to visual stimulation. To fulfill the potential of optoretinography as a biomarker for assessing function in disease, we require normative optoretinographic measurements across the retina. Here we provide such measurements. We use a custom adaptive optics scanning laser ophthalmoscope to investigate cone optoretinogram (ORG) amplitudes across retinal eccentricity in five normal-sighted participants. For this purpose, we aggregated signals across cones in each measurement (~1° by 1° patch) to provide a measurement we call the population ORG. Average population ORG amplitudes decreased with increasing eccentricity for all participants, although there were individual differences in the detailed pattern of the decrease. ORG amplitudes were correlated with the thickness of the outer retina as measured using clinical OCT, which also decreases with eccentricity. Characterizing the population cone ORG as a function of eccentricity in normal-sighted participants is an important step towards establishing norms that will allow it to be used as a biomarker for assessing photoreceptor function in retinal disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Photonics
Photonics Physics and Astronomy-Instrumentation
CiteScore
2.60
自引率
20.80%
发文量
817
审稿时长
8 weeks
期刊介绍: Photonics (ISSN 2304-6732) aims at a fast turn around time for peer-reviewing manuscripts and producing accepted articles. The online-only and open access nature of the journal will allow for a speedy and wide circulation of your research as well as review articles. We aim at establishing Photonics as a leading venue for publishing high impact fundamental research but also applications of optics and photonics. The journal particularly welcomes both theoretical (simulation) and experimental research. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书