{"title":"格拉斯哥皇家医院军团病的爆发:微生物方面。","authors":"M C Timbury, J R Donaldson, A C McCartney, R J Fallon, J D Sleigh, D Lyon, G V Orange, D R Baird, J Winter, T S Wilson","doi":"10.1017/s0022172400063580","DOIUrl":null,"url":null,"abstract":"<p><p>The bacteriological investigation of an outbreak of Legionnaires' disease in Glasgow Royal Infirmary affecting 16 patients is described. Most of the patients had been treated in high-dependency areas on two floors of the hospital supplied by the same two air-conditioned ventilation systems. The source of infection was traced to contamination of a cooling tower from which a plume of spray discharged into the intake vents of the two ventilation systems. Rubber grommets within the cooling tower probably provided a nidus of infection there. The control and management of the outbreak are discussed: a policy of frankness about the course and progress of the investigations was adopted and helped to allay anxiety on the part of both staff and media.</p>","PeriodicalId":15931,"journal":{"name":"Journal of Hygiene","volume":"97 3","pages":"393-403"},"PeriodicalIF":0.0000,"publicationDate":"1986-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1017/s0022172400063580","citationCount":"42","resultStr":"{\"title\":\"Outbreak of Legionnaires' disease in Glasgow Royal Infirmary: microbiological aspects.\",\"authors\":\"M C Timbury, J R Donaldson, A C McCartney, R J Fallon, J D Sleigh, D Lyon, G V Orange, D R Baird, J Winter, T S Wilson\",\"doi\":\"10.1017/s0022172400063580\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The bacteriological investigation of an outbreak of Legionnaires' disease in Glasgow Royal Infirmary affecting 16 patients is described. Most of the patients had been treated in high-dependency areas on two floors of the hospital supplied by the same two air-conditioned ventilation systems. The source of infection was traced to contamination of a cooling tower from which a plume of spray discharged into the intake vents of the two ventilation systems. Rubber grommets within the cooling tower probably provided a nidus of infection there. The control and management of the outbreak are discussed: a policy of frankness about the course and progress of the investigations was adopted and helped to allay anxiety on the part of both staff and media.</p>\",\"PeriodicalId\":15931,\"journal\":{\"name\":\"Journal of Hygiene\",\"volume\":\"97 3\",\"pages\":\"393-403\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1017/s0022172400063580\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/s0022172400063580\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/s0022172400063580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Outbreak of Legionnaires' disease in Glasgow Royal Infirmary: microbiological aspects.
The bacteriological investigation of an outbreak of Legionnaires' disease in Glasgow Royal Infirmary affecting 16 patients is described. Most of the patients had been treated in high-dependency areas on two floors of the hospital supplied by the same two air-conditioned ventilation systems. The source of infection was traced to contamination of a cooling tower from which a plume of spray discharged into the intake vents of the two ventilation systems. Rubber grommets within the cooling tower probably provided a nidus of infection there. The control and management of the outbreak are discussed: a policy of frankness about the course and progress of the investigations was adopted and helped to allay anxiety on the part of both staff and media.