指固有伸肌和指共伸肌在手指伸展时的特征:肌电图和运动学研究。

IF 1.6
Shota Date, Nanako Nakamae, Hiroshi Kurumadani, Runa Kamikawa, Kazuya Kurauchi, Toru Sunagawa
{"title":"指固有伸肌和指共伸肌在手指伸展时的特征:肌电图和运动学研究。","authors":"Shota Date, Nanako Nakamae, Hiroshi Kurumadani, Runa Kamikawa, Kazuya Kurauchi, Toru Sunagawa","doi":"10.1177/17531934261416296","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Functional differences between the extensor indicis proprius and extensor digitorum communis of the index finger remain poorly understood. We quantified these functional differences by measuring metacarpophalangeal joint angles and muscle activities during extension tasks.</p><p><strong>Methods: </strong>Fifteen healthy participants performed index metacarpophalangeal joint extension under two conditions: a single-finger extension task, primarily activating the extensor indicis proprius; and a four-finger extension task, extending all four fingers, primarily activating the index extensor digitorum communis. Joint kinematics were recorded using a three-dimensional motion analysis system, and muscle activities were measured via surface electromyography.</p><p><strong>Results: </strong>During the single-finger extension task, electromyography showed significantly higher extensor indicis proprius than index extensor digitorum communis activity. In contrast, there was higher index extensor digitorum communis activity during the four-finger extension task. Angle waveforms of the index metacarpophalangeal joint showed comparable flexion/extension patterns between the single-finger extension task and four-finger extension task, but greater adduction (mean 14° vs. 1°) and less internal rotation (-1° vs. 5°) were observed in the single-finger extension task compared with the four-finger extension task, indicating that the extensor indicis proprius has an adduction and external rotation action on this joint.</p><p><strong>Conclusion: </strong>These findings suggest that anatomical differences between the extensor indicis proprius and index extensor digitorum communis underlie their distinct kinematic roles, and that index finger adduction/abduction and rotation may be altered following extensor indicis proprius tendon transfer.</p>","PeriodicalId":94237,"journal":{"name":"The Journal of hand surgery, European volume","volume":" ","pages":"910-918"},"PeriodicalIF":1.6000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characteristics of extensor indicis and index extensor digitorum during finger extension: an electromyographic and kinematic study.\",\"authors\":\"Shota Date, Nanako Nakamae, Hiroshi Kurumadani, Runa Kamikawa, Kazuya Kurauchi, Toru Sunagawa\",\"doi\":\"10.1177/17531934261416296\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Functional differences between the extensor indicis proprius and extensor digitorum communis of the index finger remain poorly understood. We quantified these functional differences by measuring metacarpophalangeal joint angles and muscle activities during extension tasks.</p><p><strong>Methods: </strong>Fifteen healthy participants performed index metacarpophalangeal joint extension under two conditions: a single-finger extension task, primarily activating the extensor indicis proprius; and a four-finger extension task, extending all four fingers, primarily activating the index extensor digitorum communis. Joint kinematics were recorded using a three-dimensional motion analysis system, and muscle activities were measured via surface electromyography.</p><p><strong>Results: </strong>During the single-finger extension task, electromyography showed significantly higher extensor indicis proprius than index extensor digitorum communis activity. In contrast, there was higher index extensor digitorum communis activity during the four-finger extension task. Angle waveforms of the index metacarpophalangeal joint showed comparable flexion/extension patterns between the single-finger extension task and four-finger extension task, but greater adduction (mean 14° vs. 1°) and less internal rotation (-1° vs. 5°) were observed in the single-finger extension task compared with the four-finger extension task, indicating that the extensor indicis proprius has an adduction and external rotation action on this joint.</p><p><strong>Conclusion: </strong>These findings suggest that anatomical differences between the extensor indicis proprius and index extensor digitorum communis underlie their distinct kinematic roles, and that index finger adduction/abduction and rotation may be altered following extensor indicis proprius tendon transfer.</p>\",\"PeriodicalId\":94237,\"journal\":{\"name\":\"The Journal of hand surgery, European volume\",\"volume\":\" \",\"pages\":\"910-918\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2026-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of hand surgery, European volume\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934261416296\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2026/2/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of hand surgery, European volume","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17531934261416296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍:食指固有伸肌和指共伸肌之间的功能差异仍然知之甚少。我们通过测量掌指关节角度和伸展任务中的肌肉活动来量化这些功能差异。方法:15名健康参与者在两种情况下进行食指掌指关节伸展:单指伸展任务,主要是激活食指固有伸肌;还有一个四指伸展任务,伸展所有四个手指,主要是激活食指伸肌。使用三维运动分析系统记录关节运动学,并通过表面肌电图测量肌肉活动。结果:在单指伸展任务中,肌电图显示食指固有伸肌活动明显高于指跖伸肌活动。相比之下,在四指伸展任务中,食指伸肌的活动更高。食指掌指关节的角度波形在单指伸展任务和四指伸展任务中显示出相似的屈伸模式,但与四指伸展任务相比,单指伸展任务中观察到更大的内收(平均14°比1°)和更少的内旋(-1°比5°),表明食指固有伸肌对该关节具有内收和外旋作用。结论:这些研究结果表明,食指固有伸肌和指群食指伸肌之间的解剖学差异是其不同的运动学作用的基础,并且食指固有伸肌肌腱转移可能会改变食指内收/外展和旋转。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characteristics of extensor indicis and index extensor digitorum during finger extension: an electromyographic and kinematic study.

Introduction: Functional differences between the extensor indicis proprius and extensor digitorum communis of the index finger remain poorly understood. We quantified these functional differences by measuring metacarpophalangeal joint angles and muscle activities during extension tasks.

Methods: Fifteen healthy participants performed index metacarpophalangeal joint extension under two conditions: a single-finger extension task, primarily activating the extensor indicis proprius; and a four-finger extension task, extending all four fingers, primarily activating the index extensor digitorum communis. Joint kinematics were recorded using a three-dimensional motion analysis system, and muscle activities were measured via surface electromyography.

Results: During the single-finger extension task, electromyography showed significantly higher extensor indicis proprius than index extensor digitorum communis activity. In contrast, there was higher index extensor digitorum communis activity during the four-finger extension task. Angle waveforms of the index metacarpophalangeal joint showed comparable flexion/extension patterns between the single-finger extension task and four-finger extension task, but greater adduction (mean 14° vs. 1°) and less internal rotation (-1° vs. 5°) were observed in the single-finger extension task compared with the four-finger extension task, indicating that the extensor indicis proprius has an adduction and external rotation action on this joint.

Conclusion: These findings suggest that anatomical differences between the extensor indicis proprius and index extensor digitorum communis underlie their distinct kinematic roles, and that index finger adduction/abduction and rotation may be altered following extensor indicis proprius tendon transfer.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书