血清游离雌三醇对宫内生长迟缓的检测效果不佳。

P Palo, R Erkkola, K Irjala, E Taina
{"title":"血清游离雌三醇对宫内生长迟缓的检测效果不佳。","authors":"P Palo,&nbsp;R Erkkola,&nbsp;K Irjala,&nbsp;E Taina","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The value of a single serum free estriol (E3) measurement in the detection of intrauterine growth retardation (IUGR) was investigated. Among the group of 40 mothers later giving birth to a growth retarded baby, E3 was low, i.g. below the level of two lower standard deviations of the mean values, in 9 cases. In the control group of 50 mothers with appropriately grown newborns, none of the E3 values was low. In a group of 42 mothers with a low E3 level, only 10 gave birth to a growth retarded baby. Hence, the sensitivity of a single E3 measurement to detect IUGR is 38%, the specificity 61% and the predictive value 37%. E3 measurement is neither efficient nor accurate in the detection of IUGR.</p>","PeriodicalId":75497,"journal":{"name":"Annales chirurgiae et gynaecologiae. Supplementum","volume":"202 ","pages":"20-2"},"PeriodicalIF":0.0000,"publicationDate":"1987-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Serum free estriol inefficient in the detection of intrauterine growth retardation.\",\"authors\":\"P Palo,&nbsp;R Erkkola,&nbsp;K Irjala,&nbsp;E Taina\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The value of a single serum free estriol (E3) measurement in the detection of intrauterine growth retardation (IUGR) was investigated. Among the group of 40 mothers later giving birth to a growth retarded baby, E3 was low, i.g. below the level of two lower standard deviations of the mean values, in 9 cases. In the control group of 50 mothers with appropriately grown newborns, none of the E3 values was low. In a group of 42 mothers with a low E3 level, only 10 gave birth to a growth retarded baby. Hence, the sensitivity of a single E3 measurement to detect IUGR is 38%, the specificity 61% and the predictive value 37%. E3 measurement is neither efficient nor accurate in the detection of IUGR.</p>\",\"PeriodicalId\":75497,\"journal\":{\"name\":\"Annales chirurgiae et gynaecologiae. Supplementum\",\"volume\":\"202 \",\"pages\":\"20-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1987-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annales chirurgiae et gynaecologiae. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales chirurgiae et gynaecologiae. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

探讨单次血清游离雌三醇(E3)测定对宫内生长迟缓(IUGR)的检测价值。在40例后生发育迟缓婴儿的母亲组中,E3较低,即低于平均值下两个标准差的水平,有9例。在对照组的50位母亲中,她们的新生儿发育正常,E3值都不低。在一组42位E3水平较低的母亲中,只有10位生下了发育迟缓的婴儿。因此,单次E3检测IUGR的敏感性为38%,特异性为61%,预测值为37%。E3测量在IUGR检测中既不高效也不准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Serum free estriol inefficient in the detection of intrauterine growth retardation.

The value of a single serum free estriol (E3) measurement in the detection of intrauterine growth retardation (IUGR) was investigated. Among the group of 40 mothers later giving birth to a growth retarded baby, E3 was low, i.g. below the level of two lower standard deviations of the mean values, in 9 cases. In the control group of 50 mothers with appropriately grown newborns, none of the E3 values was low. In a group of 42 mothers with a low E3 level, only 10 gave birth to a growth retarded baby. Hence, the sensitivity of a single E3 measurement to detect IUGR is 38%, the specificity 61% and the predictive value 37%. E3 measurement is neither efficient nor accurate in the detection of IUGR.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信