{"title":"血清游离雌三醇对宫内生长迟缓的检测效果不佳。","authors":"P Palo, R Erkkola, K Irjala, E Taina","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The value of a single serum free estriol (E3) measurement in the detection of intrauterine growth retardation (IUGR) was investigated. Among the group of 40 mothers later giving birth to a growth retarded baby, E3 was low, i.g. below the level of two lower standard deviations of the mean values, in 9 cases. In the control group of 50 mothers with appropriately grown newborns, none of the E3 values was low. In a group of 42 mothers with a low E3 level, only 10 gave birth to a growth retarded baby. Hence, the sensitivity of a single E3 measurement to detect IUGR is 38%, the specificity 61% and the predictive value 37%. E3 measurement is neither efficient nor accurate in the detection of IUGR.</p>","PeriodicalId":75497,"journal":{"name":"Annales chirurgiae et gynaecologiae. Supplementum","volume":"202 ","pages":"20-2"},"PeriodicalIF":0.0000,"publicationDate":"1987-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Serum free estriol inefficient in the detection of intrauterine growth retardation.\",\"authors\":\"P Palo, R Erkkola, K Irjala, E Taina\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The value of a single serum free estriol (E3) measurement in the detection of intrauterine growth retardation (IUGR) was investigated. Among the group of 40 mothers later giving birth to a growth retarded baby, E3 was low, i.g. below the level of two lower standard deviations of the mean values, in 9 cases. In the control group of 50 mothers with appropriately grown newborns, none of the E3 values was low. In a group of 42 mothers with a low E3 level, only 10 gave birth to a growth retarded baby. Hence, the sensitivity of a single E3 measurement to detect IUGR is 38%, the specificity 61% and the predictive value 37%. E3 measurement is neither efficient nor accurate in the detection of IUGR.</p>\",\"PeriodicalId\":75497,\"journal\":{\"name\":\"Annales chirurgiae et gynaecologiae. Supplementum\",\"volume\":\"202 \",\"pages\":\"20-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1987-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annales chirurgiae et gynaecologiae. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales chirurgiae et gynaecologiae. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Serum free estriol inefficient in the detection of intrauterine growth retardation.
The value of a single serum free estriol (E3) measurement in the detection of intrauterine growth retardation (IUGR) was investigated. Among the group of 40 mothers later giving birth to a growth retarded baby, E3 was low, i.g. below the level of two lower standard deviations of the mean values, in 9 cases. In the control group of 50 mothers with appropriately grown newborns, none of the E3 values was low. In a group of 42 mothers with a low E3 level, only 10 gave birth to a growth retarded baby. Hence, the sensitivity of a single E3 measurement to detect IUGR is 38%, the specificity 61% and the predictive value 37%. E3 measurement is neither efficient nor accurate in the detection of IUGR.