标准人工晶状体和吸收紫外线人工晶状体假晶状体的视力表现:初步报告。

H M Hammer, M Yap, J R Weatherill
{"title":"标准人工晶状体和吸收紫外线人工晶状体假晶状体的视力表现:初步报告。","authors":"H M Hammer,&nbsp;M Yap,&nbsp;J R Weatherill","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>There is currently considerably interest in the vulnerability of the pseudophakic eye ultraviolet light. Contrast sensitivity was measured in patients receiving UV-absorbing and standard posterior chamber intraocular lenses (IOLs) and in normal age-matched observers. The results suggest that in the relative short-term there is no difference in visual performance with either type of IOL. Modulation Transfer Function studies on 3 batches of IOLs (2 standard and 1 UV-absorbing) showed slight variations in optical performance within and between batches. Spectral sensitivity testing demonstrated increased macular protection from short wave-length blue light by the crystalline lens when compared with both types of IOL.</p>","PeriodicalId":76757,"journal":{"name":"Transactions of the ophthalmological societies of the United Kingdom","volume":"105 ( Pt 4) ","pages":"441-6"},"PeriodicalIF":0.0000,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual performance in pseudophakia with standard and ultraviolet-absorbing intraocular lenses: a preliminary report.\",\"authors\":\"H M Hammer,&nbsp;M Yap,&nbsp;J R Weatherill\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There is currently considerably interest in the vulnerability of the pseudophakic eye ultraviolet light. Contrast sensitivity was measured in patients receiving UV-absorbing and standard posterior chamber intraocular lenses (IOLs) and in normal age-matched observers. The results suggest that in the relative short-term there is no difference in visual performance with either type of IOL. Modulation Transfer Function studies on 3 batches of IOLs (2 standard and 1 UV-absorbing) showed slight variations in optical performance within and between batches. Spectral sensitivity testing demonstrated increased macular protection from short wave-length blue light by the crystalline lens when compared with both types of IOL.</p>\",\"PeriodicalId\":76757,\"journal\":{\"name\":\"Transactions of the ophthalmological societies of the United Kingdom\",\"volume\":\"105 ( Pt 4) \",\"pages\":\"441-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of the ophthalmological societies of the United Kingdom\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the ophthalmological societies of the United Kingdom","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前,人们对假晶状眼紫外光的脆弱性有相当大的兴趣。对比敏感度在接受紫外线吸收和标准后房人工晶状体(iol)的患者和正常年龄匹配的观察者中进行测量。结果表明,在相对短期内,两种类型的人工晶状体的视力没有差异。对3批iol(2批标准型和1批吸收型)的调制传递函数研究表明,批次内和批次之间的光学性能略有差异。光谱灵敏度测试表明,与两种类型的人工晶状体相比,晶状体对短波蓝光的保护作用增强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Visual performance in pseudophakia with standard and ultraviolet-absorbing intraocular lenses: a preliminary report.

There is currently considerably interest in the vulnerability of the pseudophakic eye ultraviolet light. Contrast sensitivity was measured in patients receiving UV-absorbing and standard posterior chamber intraocular lenses (IOLs) and in normal age-matched observers. The results suggest that in the relative short-term there is no difference in visual performance with either type of IOL. Modulation Transfer Function studies on 3 batches of IOLs (2 standard and 1 UV-absorbing) showed slight variations in optical performance within and between batches. Spectral sensitivity testing demonstrated increased macular protection from short wave-length blue light by the crystalline lens when compared with both types of IOL.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信