ESUS卒中后早期与延迟插入式心脏监护仪植入与房颤检出率:一项系统回顾和荟萃分析

IF 6.9 2区 医学 Q1 CLINICAL NEUROLOGY
International Journal of Stroke Pub Date : 2026-08-01 Epub Date: 2025-11-26 DOI:10.1177/17474930251404336
Lucio D'Anna, Gabriele Prandin, Matteo Foschi, Samir Abu-Rumeileh, Francesco Favruzzo, Renato Simonetti, Lorenzo Barba, Giovanni Merlino, Francesco Bax, Arsalan Faiz, Markus Otto, Jianqun Guan, Asha Barnard, Lydia Jeffrey, Jake Dagan, Tsering Dolkar, Jonathan Hayton, Mariarosaria Valente, Gian Luigi Gigli, Simona Sacco, Maurizio Paciaroni, Arvind Chandratheva, Robert Simister, Soma Banerjee, Phang Boon Lim
{"title":"ESUS卒中后早期与延迟插入式心脏监护仪植入与房颤检出率:一项系统回顾和荟萃分析","authors":"Lucio D'Anna, Gabriele Prandin, Matteo Foschi, Samir Abu-Rumeileh, Francesco Favruzzo, Renato Simonetti, Lorenzo Barba, Giovanni Merlino, Francesco Bax, Arsalan Faiz, Markus Otto, Jianqun Guan, Asha Barnard, Lydia Jeffrey, Jake Dagan, Tsering Dolkar, Jonathan Hayton, Mariarosaria Valente, Gian Luigi Gigli, Simona Sacco, Maurizio Paciaroni, Arvind Chandratheva, Robert Simister, Soma Banerjee, Phang Boon Lim","doi":"10.1177/17474930251404336","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The clinical utility of implantable cardiac monitors (ICMs) for atrial fibrillation (AF) detection following cryptogenic stroke or embolic stroke of undetermined source (ESUS) is well established. However, the optimal timing for ICM implantation to maximize diagnostic yield remains uncertain.</p><p><strong>Aims: </strong>To systematically review the literature and conduct a meta-analysis to determine whether earlier ICM implantation after cryptogenic stroke or ESUS ischemic stroke improves detection rates and reduces the time to AF diagnosis.</p><p><strong>Summary of review: </strong>A comprehensive search of PubMed, Embase, and Cochrane CENTRAL was conducted from inception to June 2025, without language restrictions. References of retrieved articles and relevant reviews were manually searched. We included observational studies or randomized trials reporting ICM use in patients with ESUS or cryptogenic stroke/transient ischemic attack (TIA), providing data on AF detection rates and/or timing metrics (stroke-to-ICM interval, ICM-to-AF interval). Two reviewers independently screened studies and extracted data. Disagreements were resolved by consensus or third-party adjudication. Data were extracted following Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. Study-level AF detection rates were modeled using logit-transformed proportions and pooled using random-effects models (REML). Mixed-effects meta-regressions assessed the effect of timing (stroke-to-ICM interval) on AF detection and diagnostic delay, adjusting for ICM monitoring duration. The primary outcomes were pooled AF detection rate and mean time from ICM implantation to AF diagnosis. Timing of implantation was assessed as a continuous and categorical (early, intermediate, delayed) variable. Forty-seven studies (<i>N</i> = 6918 patients) were included. The pooled AF detection rate was 27.3% (95% CI: 24.6-30.2), with substantial heterogeneity (<i>I</i><sup>2</sup> = 80.8%). Early ICM implantation (<31.5 days from index event) was associated with a higher AF detection rate compared with delayed implantation (30.0% vs 23.7%; <i>p</i> = 0.0017), independent of monitoring duration. Stratified meta-regression confirmed that delayed implantation was associated with lower AF detection even after adjusting for ICM duration. For each additional day of delay in ICM implantation, the time from AF diagnosis increased by an additional 0.32 days on average, even after accounting for monitoring duration (<i>p</i> = 0.0007).</p><p><strong>Conclusion: </strong>These findings suggest that earlier ICM implantation enhances AF detection after ESUS or cryptogenic stroke and shortens diagnostic delay. Optimizing timing of post-stroke monitoring may improve patient selection for anticoagulation and reduce recurrent stroke risk.CRD 420251064227.</p>","PeriodicalId":14442,"journal":{"name":"International Journal of Stroke","volume":" ","pages":"923-932"},"PeriodicalIF":6.9000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13392177/pdf/","citationCount":"0","resultStr":"{\"title\":\"Early versus delayed insertable cardiac monitor implantation after ESUS stroke and the yield of atrial fibrillation detection: A systematic review and meta-analysis.\",\"authors\":\"Lucio D'Anna, Gabriele Prandin, Matteo Foschi, Samir Abu-Rumeileh, Francesco Favruzzo, Renato Simonetti, Lorenzo Barba, Giovanni Merlino, Francesco Bax, Arsalan Faiz, Markus Otto, Jianqun Guan, Asha Barnard, Lydia Jeffrey, Jake Dagan, Tsering Dolkar, Jonathan Hayton, Mariarosaria Valente, Gian Luigi Gigli, Simona Sacco, Maurizio Paciaroni, Arvind Chandratheva, Robert Simister, Soma Banerjee, Phang Boon Lim\",\"doi\":\"10.1177/17474930251404336\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The clinical utility of implantable cardiac monitors (ICMs) for atrial fibrillation (AF) detection following cryptogenic stroke or embolic stroke of undetermined source (ESUS) is well established. However, the optimal timing for ICM implantation to maximize diagnostic yield remains uncertain.</p><p><strong>Aims: </strong>To systematically review the literature and conduct a meta-analysis to determine whether earlier ICM implantation after cryptogenic stroke or ESUS ischemic stroke improves detection rates and reduces the time to AF diagnosis.</p><p><strong>Summary of review: </strong>A comprehensive search of PubMed, Embase, and Cochrane CENTRAL was conducted from inception to June 2025, without language restrictions. References of retrieved articles and relevant reviews were manually searched. We included observational studies or randomized trials reporting ICM use in patients with ESUS or cryptogenic stroke/transient ischemic attack (TIA), providing data on AF detection rates and/or timing metrics (stroke-to-ICM interval, ICM-to-AF interval). Two reviewers independently screened studies and extracted data. Disagreements were resolved by consensus or third-party adjudication. Data were extracted following Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. Study-level AF detection rates were modeled using logit-transformed proportions and pooled using random-effects models (REML). Mixed-effects meta-regressions assessed the effect of timing (stroke-to-ICM interval) on AF detection and diagnostic delay, adjusting for ICM monitoring duration. The primary outcomes were pooled AF detection rate and mean time from ICM implantation to AF diagnosis. Timing of implantation was assessed as a continuous and categorical (early, intermediate, delayed) variable. Forty-seven studies (<i>N</i> = 6918 patients) were included. The pooled AF detection rate was 27.3% (95% CI: 24.6-30.2), with substantial heterogeneity (<i>I</i><sup>2</sup> = 80.8%). Early ICM implantation (<31.5 days from index event) was associated with a higher AF detection rate compared with delayed implantation (30.0% vs 23.7%; <i>p</i> = 0.0017), independent of monitoring duration. Stratified meta-regression confirmed that delayed implantation was associated with lower AF detection even after adjusting for ICM duration. For each additional day of delay in ICM implantation, the time from AF diagnosis increased by an additional 0.32 days on average, even after accounting for monitoring duration (<i>p</i> = 0.0007).</p><p><strong>Conclusion: </strong>These findings suggest that earlier ICM implantation enhances AF detection after ESUS or cryptogenic stroke and shortens diagnostic delay. Optimizing timing of post-stroke monitoring may improve patient selection for anticoagulation and reduce recurrent stroke risk.CRD 420251064227.</p>\",\"PeriodicalId\":14442,\"journal\":{\"name\":\"International Journal of Stroke\",\"volume\":\" \",\"pages\":\"923-932\"},\"PeriodicalIF\":6.9000,\"publicationDate\":\"2026-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13392177/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Stroke\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17474930251404336\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/11/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Stroke","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17474930251404336","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:植入式心脏监护仪(ICMs)用于隐匿性卒中或不明来源栓塞性卒中(ESUS)后房颤(AF)检测的临床应用已经得到了很好的证实。然而,ICM植入的最佳时机,以最大限度地提高诊断率仍然不确定。目的:系统回顾文献并进行荟萃分析,以确定隐源性卒中或ESUS缺血性卒中后早期植入ICM是否能提高检出率并缩短房颤诊断时间。综述摘要:我们对PubMed、Embase和Cochrane CENTRAL数据库进行了全面检索,检索时间从成立到2025年6月,没有语言限制。人工检索检索到的文章和相关综述的参考文献。我们纳入了观察性研究或随机试验,报告了ESUS或隐源性卒中/TIA患者使用ICM,提供了AF检出率和/或时间指标(卒中-ICM间期,ICM- AF间期)的数据。两位审稿人独立筛选研究并提取数据。分歧通过协商一致或第三方裁决解决。数据按照PRISMA指南提取。研究水平AF检出率采用对数变换比例建模,并采用随机效应模型(REML)进行汇总。混合效应meta回归评估了时间(卒中-ICM间隔)对房颤检测和诊断延迟的影响,调整了ICM监测持续时间。主要结局为房颤检出率和ICM植入到房颤诊断的平均时间。植入时间作为连续和分类(早期、中期、延迟)变量进行评估。纳入47项研究(N = 6,918例患者)。合并AF检出率为27.3% (95% CI: 24.6-30.2%),异质性显著(I²= 80.8%)。结论:早期植入ICM可提高ESUS或隐源性卒中后AF的检测,缩短诊断延迟。优化卒中后监测时机可以改善患者抗凝治疗的选择,降低卒中复发风险。CRD 420251064227。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Early versus delayed insertable cardiac monitor implantation after ESUS stroke and the yield of atrial fibrillation detection: A systematic review and meta-analysis.

Background: The clinical utility of implantable cardiac monitors (ICMs) for atrial fibrillation (AF) detection following cryptogenic stroke or embolic stroke of undetermined source (ESUS) is well established. However, the optimal timing for ICM implantation to maximize diagnostic yield remains uncertain.

Aims: To systematically review the literature and conduct a meta-analysis to determine whether earlier ICM implantation after cryptogenic stroke or ESUS ischemic stroke improves detection rates and reduces the time to AF diagnosis.

Summary of review: A comprehensive search of PubMed, Embase, and Cochrane CENTRAL was conducted from inception to June 2025, without language restrictions. References of retrieved articles and relevant reviews were manually searched. We included observational studies or randomized trials reporting ICM use in patients with ESUS or cryptogenic stroke/transient ischemic attack (TIA), providing data on AF detection rates and/or timing metrics (stroke-to-ICM interval, ICM-to-AF interval). Two reviewers independently screened studies and extracted data. Disagreements were resolved by consensus or third-party adjudication. Data were extracted following Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines. Study-level AF detection rates were modeled using logit-transformed proportions and pooled using random-effects models (REML). Mixed-effects meta-regressions assessed the effect of timing (stroke-to-ICM interval) on AF detection and diagnostic delay, adjusting for ICM monitoring duration. The primary outcomes were pooled AF detection rate and mean time from ICM implantation to AF diagnosis. Timing of implantation was assessed as a continuous and categorical (early, intermediate, delayed) variable. Forty-seven studies (N = 6918 patients) were included. The pooled AF detection rate was 27.3% (95% CI: 24.6-30.2), with substantial heterogeneity (I2 = 80.8%). Early ICM implantation (<31.5 days from index event) was associated with a higher AF detection rate compared with delayed implantation (30.0% vs 23.7%; p = 0.0017), independent of monitoring duration. Stratified meta-regression confirmed that delayed implantation was associated with lower AF detection even after adjusting for ICM duration. For each additional day of delay in ICM implantation, the time from AF diagnosis increased by an additional 0.32 days on average, even after accounting for monitoring duration (p = 0.0007).

Conclusion: These findings suggest that earlier ICM implantation enhances AF detection after ESUS or cryptogenic stroke and shortens diagnostic delay. Optimizing timing of post-stroke monitoring may improve patient selection for anticoagulation and reduce recurrent stroke risk.CRD 420251064227.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Stroke
International Journal of Stroke 医学-外周血管病
CiteScore
13.90
自引率
6.00%
发文量
132
审稿时长
6-12 weeks
期刊介绍: The International Journal of Stroke is a welcome addition to the international stroke journal landscape in that it concentrates on the clinical aspects of stroke with basic science contributions in areas of clinical interest. Reviews of current topics are broadly based to encompass not only recent advances of global interest but also those which may be more important in certain regions and the journal regularly features items of news interest from all parts of the world. To facilitate the international nature of the journal, our Associate Editors from Europe, Asia, North America and South America coordinate segments of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书