新墨西哥州阿尔伯克基室内住宅二氧化氮浓度。

M C Marbury, D P Harlos, J M Samet, J D Spengler
{"title":"新墨西哥州阿尔伯克基室内住宅二氧化氮浓度。","authors":"M C Marbury, D P Harlos, J M Samet, J D Spengler","doi":"10.1080/08940630.1988.10466388","DOIUrl":null,"url":null,"abstract":"In preparation for a prospective study of the relationship of residential nitrogen dioxide exposure and respiratory infections in infants, we conducted a pilot study to assess NO2 concentrations in a sample of homes in Albuquerque, New Mexico. The methods used to characterize concentrations are described. Three locations in 144 homes were monitored with passive diffusion samplers for two two-week cycles during November and December 1984. Two-week average NO2 concentrations in the activity room ranged from 2.0 to 168.7 ppb. NO2 concentrations in the activity room and the infant’s bedroom were fivefold higher in homes with gas stoves than in homes with electric stoves. Sixty-four percent of homes with gas stoves had activity room concentrations that exceeded the highest outdoor concentration. Multiple regression models Indicated that the outdoor concentration, use of a gas stove, particularly one with pilot lights, presence of a gas dryer in the living area, and use of a floor or wall furnace contributed to...","PeriodicalId":77731,"journal":{"name":"JAPCA","volume":"38 4","pages":"392-8"},"PeriodicalIF":0.0000,"publicationDate":"1988-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08940630.1988.10466388","citationCount":"29","resultStr":"{\"title\":\"Indoor residential NO2 concentrations in Albuquerque, New Mexico.\",\"authors\":\"M C Marbury, D P Harlos, J M Samet, J D Spengler\",\"doi\":\"10.1080/08940630.1988.10466388\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In preparation for a prospective study of the relationship of residential nitrogen dioxide exposure and respiratory infections in infants, we conducted a pilot study to assess NO2 concentrations in a sample of homes in Albuquerque, New Mexico. The methods used to characterize concentrations are described. Three locations in 144 homes were monitored with passive diffusion samplers for two two-week cycles during November and December 1984. Two-week average NO2 concentrations in the activity room ranged from 2.0 to 168.7 ppb. NO2 concentrations in the activity room and the infant’s bedroom were fivefold higher in homes with gas stoves than in homes with electric stoves. Sixty-four percent of homes with gas stoves had activity room concentrations that exceeded the highest outdoor concentration. Multiple regression models Indicated that the outdoor concentration, use of a gas stove, particularly one with pilot lights, presence of a gas dryer in the living area, and use of a floor or wall furnace contributed to...\",\"PeriodicalId\":77731,\"journal\":{\"name\":\"JAPCA\",\"volume\":\"38 4\",\"pages\":\"392-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/08940630.1988.10466388\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JAPCA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/08940630.1988.10466388\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAPCA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08940630.1988.10466388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Indoor residential NO2 concentrations in Albuquerque, New Mexico.
In preparation for a prospective study of the relationship of residential nitrogen dioxide exposure and respiratory infections in infants, we conducted a pilot study to assess NO2 concentrations in a sample of homes in Albuquerque, New Mexico. The methods used to characterize concentrations are described. Three locations in 144 homes were monitored with passive diffusion samplers for two two-week cycles during November and December 1984. Two-week average NO2 concentrations in the activity room ranged from 2.0 to 168.7 ppb. NO2 concentrations in the activity room and the infant’s bedroom were fivefold higher in homes with gas stoves than in homes with electric stoves. Sixty-four percent of homes with gas stoves had activity room concentrations that exceeded the highest outdoor concentration. Multiple regression models Indicated that the outdoor concentration, use of a gas stove, particularly one with pilot lights, presence of a gas dryer in the living area, and use of a floor or wall furnace contributed to...
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信