诊断转化考虑全球卫生设置:便携式检测人乳头瘤病毒宫颈癌筛查在印度。

IF 3 Q2 ONCOLOGY
JCO Global Oncology Pub Date : 2025-10-01 Epub Date: 2025-10-03 DOI:10.1200/GO-25-00117
Vi T Nguyen, Siril Arockiam, Pankaj Kumar, Joshua Eger, Kirk Herman, Shachi Vashist, Neerja Bhatla, Lalit Dar, Dean E Brenner, Karen S Anderson, Jennifer Blain Christen
{"title":"诊断转化考虑全球卫生设置:便携式检测人乳头瘤病毒宫颈癌筛查在印度。","authors":"Vi T Nguyen, Siril Arockiam, Pankaj Kumar, Joshua Eger, Kirk Herman, Shachi Vashist, Neerja Bhatla, Lalit Dar, Dean E Brenner, Karen S Anderson, Jennifer Blain Christen","doi":"10.1200/GO-25-00117","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Translation of diagnostic technology developed at the laboratory bench involves iterations of user feedback and design modifications. Learning about translational requirements early in the design process facilitates the development of feasible prototypes that have a better likelihood of implementation in global health settings. During our development of a portable system to detect human papillomavirus (HPV) for cervical cancer screening in India, we encountered and solved issues related to research translation. We report our findings to help others deploying diagnostic technology for global health.</p><p><strong>Materials and methods: </strong>We designed a point-of-care system to process patient samples and diagnose HPV infection in the cervix. We continually shipped components of the system from the United States to our collaborating team in India to assess component condition and usability at the local site. We simultaneously developed HPV isothermal amplification assays that were fit for purpose. Cervical brush samples were used in our portable system for functional validation.</p><p><strong>Results: </strong>We found ideal transport methods to ensure component quality and reagent stability through the international shipment chain. Portable systems should be designed as simple as possible for correct usage at the local testing site. Usability tests drove our design improvements from 28% to 93% success rates. We demonstrated proof-of-concept functionality of our portable system for 13 cervical brush samples on-site, with a sensitivity of 100% and specificity of 88.9%.</p><p><strong>Conclusion: </strong>Issues related to technology transfer for global health settings manifest during distribution and deployment of prototypes. We identified several issues during our synergistic design process and report recommendations on the basis of our experience.</p>","PeriodicalId":14806,"journal":{"name":"JCO Global Oncology","volume":"11 ","pages":"e2500117"},"PeriodicalIF":3.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic Translational Considerations for Global Health Settings: Portable Detection of Human Papillomavirus for Cervical Cancer Screening in India.\",\"authors\":\"Vi T Nguyen, Siril Arockiam, Pankaj Kumar, Joshua Eger, Kirk Herman, Shachi Vashist, Neerja Bhatla, Lalit Dar, Dean E Brenner, Karen S Anderson, Jennifer Blain Christen\",\"doi\":\"10.1200/GO-25-00117\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Translation of diagnostic technology developed at the laboratory bench involves iterations of user feedback and design modifications. Learning about translational requirements early in the design process facilitates the development of feasible prototypes that have a better likelihood of implementation in global health settings. During our development of a portable system to detect human papillomavirus (HPV) for cervical cancer screening in India, we encountered and solved issues related to research translation. We report our findings to help others deploying diagnostic technology for global health.</p><p><strong>Materials and methods: </strong>We designed a point-of-care system to process patient samples and diagnose HPV infection in the cervix. We continually shipped components of the system from the United States to our collaborating team in India to assess component condition and usability at the local site. We simultaneously developed HPV isothermal amplification assays that were fit for purpose. Cervical brush samples were used in our portable system for functional validation.</p><p><strong>Results: </strong>We found ideal transport methods to ensure component quality and reagent stability through the international shipment chain. Portable systems should be designed as simple as possible for correct usage at the local testing site. Usability tests drove our design improvements from 28% to 93% success rates. We demonstrated proof-of-concept functionality of our portable system for 13 cervical brush samples on-site, with a sensitivity of 100% and specificity of 88.9%.</p><p><strong>Conclusion: </strong>Issues related to technology transfer for global health settings manifest during distribution and deployment of prototypes. We identified several issues during our synergistic design process and report recommendations on the basis of our experience.</p>\",\"PeriodicalId\":14806,\"journal\":{\"name\":\"JCO Global Oncology\",\"volume\":\"11 \",\"pages\":\"e2500117\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JCO Global Oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1200/GO-25-00117\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/10/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JCO Global Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1200/GO-25-00117","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/3 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:在实验室工作台开发的诊断技术的翻译涉及用户反馈和设计修改的迭代。在设计过程的早期了解转化要求有助于开发可行的原型,这些原型更有可能在全球卫生环境中实施。在印度开发用于宫颈癌筛查的便携式人乳头瘤病毒(HPV)检测系统的过程中,我们遇到并解决了与研究翻译相关的问题。我们报告我们的发现,以帮助其他人为全球健康部署诊断技术。材料和方法:我们设计了一个护理点系统来处理患者样本和诊断宫颈HPV感染。我们不断地将系统的组件从美国运送到我们在印度的合作团队,以评估组件在当地站点的状况和可用性。我们同时开发了适合目的的HPV等温扩增测定法。宫颈刷样用于我们的便携式系统进行功能验证。结果:通过国际运输链找到了理想的运输方式,保证了组分质量和试剂稳定性。便携式系统应设计得尽可能简单,以便在当地测试现场正确使用。可用性测试使我们的设计改进成功率从28%提高到93%。我们在13个宫颈刷样现场演示了便携式系统的概念验证功能,灵敏度为100%,特异性为88.9%。结论:在原型的分发和部署过程中,与全球卫生环境技术转让有关的问题表现出来。我们在协同设计过程中发现了几个问题,并根据我们的经验提出了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnostic Translational Considerations for Global Health Settings: Portable Detection of Human Papillomavirus for Cervical Cancer Screening in India.

Purpose: Translation of diagnostic technology developed at the laboratory bench involves iterations of user feedback and design modifications. Learning about translational requirements early in the design process facilitates the development of feasible prototypes that have a better likelihood of implementation in global health settings. During our development of a portable system to detect human papillomavirus (HPV) for cervical cancer screening in India, we encountered and solved issues related to research translation. We report our findings to help others deploying diagnostic technology for global health.

Materials and methods: We designed a point-of-care system to process patient samples and diagnose HPV infection in the cervix. We continually shipped components of the system from the United States to our collaborating team in India to assess component condition and usability at the local site. We simultaneously developed HPV isothermal amplification assays that were fit for purpose. Cervical brush samples were used in our portable system for functional validation.

Results: We found ideal transport methods to ensure component quality and reagent stability through the international shipment chain. Portable systems should be designed as simple as possible for correct usage at the local testing site. Usability tests drove our design improvements from 28% to 93% success rates. We demonstrated proof-of-concept functionality of our portable system for 13 cervical brush samples on-site, with a sensitivity of 100% and specificity of 88.9%.

Conclusion: Issues related to technology transfer for global health settings manifest during distribution and deployment of prototypes. We identified several issues during our synergistic design process and report recommendations on the basis of our experience.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JCO Global Oncology
JCO Global Oncology Medicine-Oncology
CiteScore
6.70
自引率
6.70%
发文量
310
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信