{"title":"全膝关节置换术中假体放置角度影响中长期临床结果:一项平均8年随访研究。","authors":"Koki Kawada, Yusuke Yokoyama, Tomonori Tetsunaga, Kazuki Yamada, Yuki Okazaki, Toshiki Kohara, Toshifumi Ozaki","doi":"10.1007/s00402-025-06080-8","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Few studies have examined how the component placement angles in total knee arthroplasty (TKA) affect mid- to long-term clinical outcomes. This study investigated the influence of coronal and sagittal plane component placement angles on mid- to long-term outcomes in mechanical alignment TKA.</p><h3>Materials and Methods</h3><p>Forty-eight knees undergoing TKA using the FINE Total Knee System were evaluated for range of motion (ROM) preoperatively. Both ROM and clinical scores were evaluated at 3 and 5 years postoperatively and at the final follow-up (average 8-year). The valgus (alpha) and flexion (gamma) angles of the femoral component, and the varus (beta) and posterior tilt (sigma) angles of the tibial component were evaluated. Correlations between radiographic assessments, knee ROM, and clinical scores were assessed using Spearman's correlation coefficient.</p><h3>Results</h3><p>The alpha angle was negatively correlated with the knee flexion angle (r = − 0.323, p = 0.025) and ROM (r = − 0.352, p = 0.014), and the sigma angle was negatively correlated with the Knee Injury and Osteoarthritis Outcome Score (KOOS)-Symptoms at 3 years postoperatively (r = − 0.304, p = 0.036). The alpha angle was negatively correlated with the knee flexion angle (r = − 0.357, p = 0.013), ROM (r = − 0.337, p = 0.019), and KOOS-Sports and Recreation function (r = − 0.349, p = 0.015), and positively correlated with the Visual Analog Scare pain score (r = 0.307, p = 0.034) at the final follow-up. The beta angle was positively correlated with KOOS-Pain (r = 0.303, p = 0.036) and KOOS-Symptoms (r = 0.397, p = 0.005) at the final follow-up.</p><h3>Conclusions</h3><p>Valgus placement of the femoral component and varus placement of the tibial component in the FINE Total Knee System negatively impacted clinical scores at an average 8-year follow-up.</p></div>","PeriodicalId":8326,"journal":{"name":"Archives of Orthopaedic and Trauma Surgery","volume":"145 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s00402-025-06080-8.pdf","citationCount":"0","resultStr":"{\"title\":\"Component placement angles in total knee arthroplasty affect mid- to long-term clinical results: an average 8-year follow-up study\",\"authors\":\"Koki Kawada, Yusuke Yokoyama, Tomonori Tetsunaga, Kazuki Yamada, Yuki Okazaki, Toshiki Kohara, Toshifumi Ozaki\",\"doi\":\"10.1007/s00402-025-06080-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Few studies have examined how the component placement angles in total knee arthroplasty (TKA) affect mid- to long-term clinical outcomes. This study investigated the influence of coronal and sagittal plane component placement angles on mid- to long-term outcomes in mechanical alignment TKA.</p><h3>Materials and Methods</h3><p>Forty-eight knees undergoing TKA using the FINE Total Knee System were evaluated for range of motion (ROM) preoperatively. Both ROM and clinical scores were evaluated at 3 and 5 years postoperatively and at the final follow-up (average 8-year). The valgus (alpha) and flexion (gamma) angles of the femoral component, and the varus (beta) and posterior tilt (sigma) angles of the tibial component were evaluated. Correlations between radiographic assessments, knee ROM, and clinical scores were assessed using Spearman's correlation coefficient.</p><h3>Results</h3><p>The alpha angle was negatively correlated with the knee flexion angle (r = − 0.323, p = 0.025) and ROM (r = − 0.352, p = 0.014), and the sigma angle was negatively correlated with the Knee Injury and Osteoarthritis Outcome Score (KOOS)-Symptoms at 3 years postoperatively (r = − 0.304, p = 0.036). The alpha angle was negatively correlated with the knee flexion angle (r = − 0.357, p = 0.013), ROM (r = − 0.337, p = 0.019), and KOOS-Sports and Recreation function (r = − 0.349, p = 0.015), and positively correlated with the Visual Analog Scare pain score (r = 0.307, p = 0.034) at the final follow-up. The beta angle was positively correlated with KOOS-Pain (r = 0.303, p = 0.036) and KOOS-Symptoms (r = 0.397, p = 0.005) at the final follow-up.</p><h3>Conclusions</h3><p>Valgus placement of the femoral component and varus placement of the tibial component in the FINE Total Knee System negatively impacted clinical scores at an average 8-year follow-up.</p></div>\",\"PeriodicalId\":8326,\"journal\":{\"name\":\"Archives of Orthopaedic and Trauma Surgery\",\"volume\":\"145 1\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s00402-025-06080-8.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Orthopaedic and Trauma Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00402-025-06080-8\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Orthopaedic and Trauma Surgery","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s00402-025-06080-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
导言:很少有研究探讨全膝关节置换术(TKA)中假体放置角度对中长期临床结果的影响。本研究探讨冠状面和矢状面假体放置角度对机械对齐TKA中长期预后的影响。材料和方法:采用FINE全膝关节系统对48个膝关节进行TKA术前活动范围(ROM)评估。在术后3年和5年以及最后随访时(平均8年)评估ROM和临床评分。评估股骨组件的外翻角(α)和屈曲角(γ)以及胫骨组件的内翻角(β)和后倾斜角(sigma)。影像学评估、膝关节活动度和临床评分之间的相关性采用Spearman相关系数进行评估。结果:α角与膝关节屈曲角(r = - 0.323, p = 0.025)、ROM (r = - 0.352, p = 0.014)呈负相关,sigma角与术后3年膝关节损伤及骨关节炎预后评分(oos)-症状呈负相关(r = - 0.304, p = 0.036)。alpha角与膝关节屈曲角(r = - 0.357, p = 0.013)、ROM (r = - 0.337, p = 0.019)、KOOS-Sports and Recreation函数(r = - 0.349, p = 0.015)呈负相关,与视觉模拟惊吓疼痛评分(r = 0.307, p = 0.034)呈正相关。最终随访时β角与KOOS-Pain (r = 0.303, p = 0.036)和KOOS-Symptoms (r = 0.397, p = 0.005)呈正相关。结论:在FINE全膝关节系统中,股骨假体外翻放置和胫骨假体内翻放置对临床评分有负面影响,平均随访8年。
Component placement angles in total knee arthroplasty affect mid- to long-term clinical results: an average 8-year follow-up study
Introduction
Few studies have examined how the component placement angles in total knee arthroplasty (TKA) affect mid- to long-term clinical outcomes. This study investigated the influence of coronal and sagittal plane component placement angles on mid- to long-term outcomes in mechanical alignment TKA.
Materials and Methods
Forty-eight knees undergoing TKA using the FINE Total Knee System were evaluated for range of motion (ROM) preoperatively. Both ROM and clinical scores were evaluated at 3 and 5 years postoperatively and at the final follow-up (average 8-year). The valgus (alpha) and flexion (gamma) angles of the femoral component, and the varus (beta) and posterior tilt (sigma) angles of the tibial component were evaluated. Correlations between radiographic assessments, knee ROM, and clinical scores were assessed using Spearman's correlation coefficient.
Results
The alpha angle was negatively correlated with the knee flexion angle (r = − 0.323, p = 0.025) and ROM (r = − 0.352, p = 0.014), and the sigma angle was negatively correlated with the Knee Injury and Osteoarthritis Outcome Score (KOOS)-Symptoms at 3 years postoperatively (r = − 0.304, p = 0.036). The alpha angle was negatively correlated with the knee flexion angle (r = − 0.357, p = 0.013), ROM (r = − 0.337, p = 0.019), and KOOS-Sports and Recreation function (r = − 0.349, p = 0.015), and positively correlated with the Visual Analog Scare pain score (r = 0.307, p = 0.034) at the final follow-up. The beta angle was positively correlated with KOOS-Pain (r = 0.303, p = 0.036) and KOOS-Symptoms (r = 0.397, p = 0.005) at the final follow-up.
Conclusions
Valgus placement of the femoral component and varus placement of the tibial component in the FINE Total Knee System negatively impacted clinical scores at an average 8-year follow-up.
期刊介绍:
"Archives of Orthopaedic and Trauma Surgery" is a rich source of instruction and information for physicians in clinical practice and research in the extensive field of orthopaedics and traumatology. The journal publishes papers that deal with diseases and injuries of the musculoskeletal system from all fields and aspects of medicine. The journal is particularly interested in papers that satisfy the information needs of orthopaedic clinicians and practitioners. The journal places special emphasis on clinical relevance.
"Archives of Orthopaedic and Trauma Surgery" is the official journal of the German Speaking Arthroscopy Association (AGA).