{"title":"使用双腔导管测量单径向通道的透射梯度","authors":"Khaldoon Rashid MD ,&nbsp;Sheena Amin MD ,&nbsp;Rumman Syed MD ,&nbsp;Eric Rothstein MD","doi":"10.1016/j.jaccas.2025.105219","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To measure the transmitral gradient (TMG) with a dual-lumen pigtail catheter with single radial-arterial access to obtain simultaneous left atrial (LA)/left ventricular (LV) pressures.</div></div><div><h3>Key Steps</h3><div>Key steps include the following: 1) with radial arterial access, use a 5-F TIG 4.0 diagnostic catheter, and advance a 0.035-inch J-wire across the aortic valve in a retrograde fashion; 2) advance catheter into LV; 3) advance floppy 0.035-inch Tru-Torque wire beyond the mitral valve into the LA and pulmonary vein; 4) advance TIG catheter over the wire into the LA; 5) exchange TIG catheter for a Langston dual-lumen catheter; 6) place distal pigtail portion into the LA and proximal pressure port in the LV, obtain concurrent LA/LV pressures, and calculate TMG and MVA with Gorlin equation.</div></div><div><h3>Potential Pitfalls</h3><div>In patients with atrial fibrillation, advancing the catheter across the mitral valve presents risk of dislodging a preexisting thrombus from the left atrial appendage.</div></div><div><h3>Take-Home Message</h3><div>This method offers a simple and efficient approach to a direct TMG assessment.</div></div>","PeriodicalId":14792,"journal":{"name":"JACC. Case reports","volume":"30 30","pages":"Article 105219"},"PeriodicalIF":0.0000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measuring Transmitral Gradient With Single Radial Access Using a Dual-Lumen Catheter\",\"authors\":\"Khaldoon Rashid MD ,&nbsp;Sheena Amin MD ,&nbsp;Rumman Syed MD ,&nbsp;Eric Rothstein MD\",\"doi\":\"10.1016/j.jaccas.2025.105219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>To measure the transmitral gradient (TMG) with a dual-lumen pigtail catheter with single radial-arterial access to obtain simultaneous left atrial (LA)/left ventricular (LV) pressures.</div></div><div><h3>Key Steps</h3><div>Key steps include the following: 1) with radial arterial access, use a 5-F TIG 4.0 diagnostic catheter, and advance a 0.035-inch J-wire across the aortic valve in a retrograde fashion; 2) advance catheter into LV; 3) advance floppy 0.035-inch Tru-Torque wire beyond the mitral valve into the LA and pulmonary vein; 4) advance TIG catheter over the wire into the LA; 5) exchange TIG catheter for a Langston dual-lumen catheter; 6) place distal pigtail portion into the LA and proximal pressure port in the LV, obtain concurrent LA/LV pressures, and calculate TMG and MVA with Gorlin equation.</div></div><div><h3>Potential Pitfalls</h3><div>In patients with atrial fibrillation, advancing the catheter across the mitral valve presents risk of dislodging a preexisting thrombus from the left atrial appendage.</div></div><div><h3>Take-Home Message</h3><div>This method offers a simple and efficient approach to a direct TMG assessment.</div></div>\",\"PeriodicalId\":14792,\"journal\":{\"name\":\"JACC. Case reports\",\"volume\":\"30 30\",\"pages\":\"Article 105219\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JACC. Case reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666084925019990\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Case reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666084925019990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的采用单根-动脉双腔细尾导管测量左心房/左心室(LV)同时压力。关键步骤关键步骤包括以下步骤:1)桡动脉通路,使用5-F TIG 4.0诊断导管,并以逆行方式将0.035英寸的j型线穿过主动脉瓣;2)将导管推进左室;3)将0.035英寸的Tru-Torque软丝穿过二尖瓣进入左室和肺静脉;4)将TIG导管穿过导线进入LA;5)将TIG导管置换为Langston双腔导管;6)将尾纤尾远端部分分别置入左室和左室近端压力口,获取左室/左室并发压力,用Gorlin方程计算TMG和MVA。潜在的缺陷在房颤患者中,将导管穿过二尖瓣有可能使左心房附件原有的血栓移位。这种方法为直接评估TMG提供了一种简单而有效的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measuring Transmitral Gradient With Single Radial Access Using a Dual-Lumen Catheter

Objective

To measure the transmitral gradient (TMG) with a dual-lumen pigtail catheter with single radial-arterial access to obtain simultaneous left atrial (LA)/left ventricular (LV) pressures.

Key Steps

Key steps include the following: 1) with radial arterial access, use a 5-F TIG 4.0 diagnostic catheter, and advance a 0.035-inch J-wire across the aortic valve in a retrograde fashion; 2) advance catheter into LV; 3) advance floppy 0.035-inch Tru-Torque wire beyond the mitral valve into the LA and pulmonary vein; 4) advance TIG catheter over the wire into the LA; 5) exchange TIG catheter for a Langston dual-lumen catheter; 6) place distal pigtail portion into the LA and proximal pressure port in the LV, obtain concurrent LA/LV pressures, and calculate TMG and MVA with Gorlin equation.

Potential Pitfalls

In patients with atrial fibrillation, advancing the catheter across the mitral valve presents risk of dislodging a preexisting thrombus from the left atrial appendage.

Take-Home Message

This method offers a simple and efficient approach to a direct TMG assessment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JACC. Case reports
JACC. Case reports Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.30
自引率
0.00%
发文量
404
审稿时长
17 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信