老化和机械涂刷对不同厚度三维印刷和热成型对准器颜色稳定性和透明度的影响。

IF 3.2
Muhammet Fidan, Ibrahim Erhan Gelgor
{"title":"老化和机械涂刷对不同厚度三维印刷和热成型对准器颜色稳定性和透明度的影响。","authors":"Muhammet Fidan, Ibrahim Erhan Gelgor","doi":"10.2319/011325-50.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to evaluate the effect of aging and mechanical brushing on the color stability and translucency of three-dimensionally (3D) printed and thermoformed transparent aligners (clear aligners [CAs]) of different thicknesses.</p><p><strong>Materials and methods: </strong>Three types of CAs (Dentsply Sirona Essix [Group 1], Scheu-Dental Thermoforming Foils [Group 2], and 3D-printed Nexdent [Group 3]) in two thicknesses (0.75 mm and 1.0 mm) were used. Each group was divided into cleaned and noncleaned subgroups (n = 10). Samples were aged in artificial saliva and subjected to mechanical brushing. Color differences (ΔE00) and relative translucency parameter values (RTP00) were recorded at 1-week intervals over 4 weeks. Statistical analyses included generalized linear models and repeated measures analyses of variance (ANOVAs) for normally distributed parameters, and robust ANOVAs and Friedman tests for nonnormally distributed parameters (P < .05).</p><p><strong>Results: </strong>Group 1 had the highest mean RTP00 values, while Group 3 had the lowest mean RTP00 values. Noncleaned CAs exhibited higher RTP00 values than cleaned CAs (P < .05). RTP00 values decreased significantly over time, with Group 3 showing notable differences between cleaned and noncleaned subgroups. Thinner materials (0.75 mm) displayed greater color changes than thicker ones (1 mm).</p><p><strong>Conclusions: </strong>3D-printed CAs demonstrated more significant color variation and less translucency in comparison to thermoformed CAs. Regular cleaning helps maintain translucency and color stability, but the choice of aligner material is crucial.</p>","PeriodicalId":94224,"journal":{"name":"The Angle orthodontist","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of aging and mechanical brushing on color stability and translucency of three-dimensionally printed and thermoformed aligners of different thicknesses.\",\"authors\":\"Muhammet Fidan, Ibrahim Erhan Gelgor\",\"doi\":\"10.2319/011325-50.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of this study was to evaluate the effect of aging and mechanical brushing on the color stability and translucency of three-dimensionally (3D) printed and thermoformed transparent aligners (clear aligners [CAs]) of different thicknesses.</p><p><strong>Materials and methods: </strong>Three types of CAs (Dentsply Sirona Essix [Group 1], Scheu-Dental Thermoforming Foils [Group 2], and 3D-printed Nexdent [Group 3]) in two thicknesses (0.75 mm and 1.0 mm) were used. Each group was divided into cleaned and noncleaned subgroups (n = 10). Samples were aged in artificial saliva and subjected to mechanical brushing. Color differences (ΔE00) and relative translucency parameter values (RTP00) were recorded at 1-week intervals over 4 weeks. Statistical analyses included generalized linear models and repeated measures analyses of variance (ANOVAs) for normally distributed parameters, and robust ANOVAs and Friedman tests for nonnormally distributed parameters (P < .05).</p><p><strong>Results: </strong>Group 1 had the highest mean RTP00 values, while Group 3 had the lowest mean RTP00 values. Noncleaned CAs exhibited higher RTP00 values than cleaned CAs (P < .05). RTP00 values decreased significantly over time, with Group 3 showing notable differences between cleaned and noncleaned subgroups. Thinner materials (0.75 mm) displayed greater color changes than thicker ones (1 mm).</p><p><strong>Conclusions: </strong>3D-printed CAs demonstrated more significant color variation and less translucency in comparison to thermoformed CAs. Regular cleaning helps maintain translucency and color stability, but the choice of aligner material is crucial.</p>\",\"PeriodicalId\":94224,\"journal\":{\"name\":\"The Angle orthodontist\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Angle orthodontist\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2319/011325-50.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Angle orthodontist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2319/011325-50.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是评估老化和机械涂刷对不同厚度的三维(3D)打印和热成型透明矫形器(clear aligners [CAs])的颜色稳定性和透明度的影响。材料与方法:采用三种不同厚度(0.75 mm和1.0 mm)的ca (Dentsply Sirona Essix[1组]、scheui - dental Thermoforming Foils[2组]和3d打印Nexdent[3组])。每组分为清洁亚组和未清洁亚组(n = 10)。样品在人工唾液中老化,并进行机械刷。色差(ΔE00)和相对半透明参数值(RTP00)在4周内每隔1周记录一次。统计分析包括正态分布参数的广义线性模型和重复测量方差分析(anova),非正态分布参数的稳健anova和Friedman检验(P < 0.05)。结果:1组RTP00平均值最高,3组RTP00平均值最低。未清洗CAs的RTP00值高于清洗CAs (P < 0.05)。RTP00值随着时间的推移显著下降,第3组在清洗和未清洗的亚组之间表现出显著差异。较薄的材料(0.75 mm)比较厚的材料(1mm)显示出更大的颜色变化。结论:与热成型的ca相比,3d打印的ca具有更显著的颜色变化和更低的透明度。定期清洁有助于保持半透明和颜色的稳定性,但选择校准材料是至关重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of aging and mechanical brushing on color stability and translucency of three-dimensionally printed and thermoformed aligners of different thicknesses.

Objectives: The aim of this study was to evaluate the effect of aging and mechanical brushing on the color stability and translucency of three-dimensionally (3D) printed and thermoformed transparent aligners (clear aligners [CAs]) of different thicknesses.

Materials and methods: Three types of CAs (Dentsply Sirona Essix [Group 1], Scheu-Dental Thermoforming Foils [Group 2], and 3D-printed Nexdent [Group 3]) in two thicknesses (0.75 mm and 1.0 mm) were used. Each group was divided into cleaned and noncleaned subgroups (n = 10). Samples were aged in artificial saliva and subjected to mechanical brushing. Color differences (ΔE00) and relative translucency parameter values (RTP00) were recorded at 1-week intervals over 4 weeks. Statistical analyses included generalized linear models and repeated measures analyses of variance (ANOVAs) for normally distributed parameters, and robust ANOVAs and Friedman tests for nonnormally distributed parameters (P < .05).

Results: Group 1 had the highest mean RTP00 values, while Group 3 had the lowest mean RTP00 values. Noncleaned CAs exhibited higher RTP00 values than cleaned CAs (P < .05). RTP00 values decreased significantly over time, with Group 3 showing notable differences between cleaned and noncleaned subgroups. Thinner materials (0.75 mm) displayed greater color changes than thicker ones (1 mm).

Conclusions: 3D-printed CAs demonstrated more significant color variation and less translucency in comparison to thermoformed CAs. Regular cleaning helps maintain translucency and color stability, but the choice of aligner material is crucial.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信