脊髓刺激脉冲发生器的电池寿命:手术与经皮导线能量效率的分析与比较。

IF 2.9 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Marta Antonia Gómez González, Nicolás Cordero Tous, Carlos Sánchez Corral, Beatriz Lechuga Carrasco, Manuel Alejandro Sánchez García, Rafael Gálvez Mateos, Gonzalo Olivares Granados
{"title":"脊髓刺激脉冲发生器的电池寿命:手术与经皮导线能量效率的分析与比较。","authors":"Marta Antonia Gómez González, Nicolás Cordero Tous, Carlos Sánchez Corral, Beatriz Lechuga Carrasco, Manuel Alejandro Sánchez García, Rafael Gálvez Mateos, Gonzalo Olivares Granados","doi":"10.3390/jcm14186646","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Spinal cord stimulation (SCS) is an established therapy for chronic neuropathic pain. Although rechargeable and non-rechargeable pulse generators (PGs) are widely used, their real-world battery life and the influence of lead type on energy efficiency remain underexplored. <b>Objective:</b> To evaluate PG battery longevity and compare the performance of surgical versus percutaneous leads in terms of energy efficiency. <b>Methods:</b> We conducted a retrospective study of 283 PGs implanted at Hospital Virgen de las Nieves (Granada, Spain) from 1996 to 2023. Data on patient demographics, pain etiology, lead type and placement, stimulation modality, and PG status were extracted. A competing risks analysis was used to assess PG shutdown and early explantation over time. <b>Results:</b> Of the PGs analyzed, 43.5% were non-rechargeable and 56.5% rechargeable. Rechargeable PGs showed significantly longer battery life (mean: 82.7 vs. 38.9 months, <i>p</i> < 0.05), with a lower probability of shutdown at 50, 100, and 150 months. No significant differences in battery longevity were observed regarding lead location, stimulation type, or pain etiology. A trend toward longer battery life was observed with percutaneous leads, although not statistically significant. <b>Conclusions:</b> Rechargeable PGs demonstrated superior longevity compared to non-rechargeable models and should be considered the preferred option in most cases. While both surgical and percutaneous leads are effective, percutaneous systems may offer improved battery efficiency. Further prospective studies are warranted to confirm these findings and assess cost-effectiveness.</p>","PeriodicalId":15533,"journal":{"name":"Journal of Clinical Medicine","volume":"14 18","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12470744/pdf/","citationCount":"0","resultStr":"{\"title\":\"Battery Life of Pulse Generators in Spinal Cord Stimulation: Analysis and Comparison Between Surgical and Percutaneous Leads in Energy Efficiency.\",\"authors\":\"Marta Antonia Gómez González, Nicolás Cordero Tous, Carlos Sánchez Corral, Beatriz Lechuga Carrasco, Manuel Alejandro Sánchez García, Rafael Gálvez Mateos, Gonzalo Olivares Granados\",\"doi\":\"10.3390/jcm14186646\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background:</b> Spinal cord stimulation (SCS) is an established therapy for chronic neuropathic pain. Although rechargeable and non-rechargeable pulse generators (PGs) are widely used, their real-world battery life and the influence of lead type on energy efficiency remain underexplored. <b>Objective:</b> To evaluate PG battery longevity and compare the performance of surgical versus percutaneous leads in terms of energy efficiency. <b>Methods:</b> We conducted a retrospective study of 283 PGs implanted at Hospital Virgen de las Nieves (Granada, Spain) from 1996 to 2023. Data on patient demographics, pain etiology, lead type and placement, stimulation modality, and PG status were extracted. A competing risks analysis was used to assess PG shutdown and early explantation over time. <b>Results:</b> Of the PGs analyzed, 43.5% were non-rechargeable and 56.5% rechargeable. Rechargeable PGs showed significantly longer battery life (mean: 82.7 vs. 38.9 months, <i>p</i> < 0.05), with a lower probability of shutdown at 50, 100, and 150 months. No significant differences in battery longevity were observed regarding lead location, stimulation type, or pain etiology. A trend toward longer battery life was observed with percutaneous leads, although not statistically significant. <b>Conclusions:</b> Rechargeable PGs demonstrated superior longevity compared to non-rechargeable models and should be considered the preferred option in most cases. While both surgical and percutaneous leads are effective, percutaneous systems may offer improved battery efficiency. Further prospective studies are warranted to confirm these findings and assess cost-effectiveness.</p>\",\"PeriodicalId\":15533,\"journal\":{\"name\":\"Journal of Clinical Medicine\",\"volume\":\"14 18\",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12470744/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/jcm14186646\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcm14186646","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:脊髓刺激(SCS)是治疗慢性神经性疼痛的有效方法。虽然可充电和不可充电脉冲发生器(pg)被广泛使用,但其实际电池寿命和铅类型对能源效率的影响仍未得到充分研究。目的:评估PG电池寿命,比较手术与经皮导线在能量效率方面的表现。方法:我们对1996年至2023年在西班牙格拉纳达维珍德拉斯尼夫斯医院植入的283例PGs进行回顾性研究。提取了患者人口统计学、疼痛病因、导联类型和位置、刺激方式和PG状态的数据。竞争风险分析用于评估PG关闭和早期外植体随时间的变化。结果:在所分析的pg中,43.5%为不可充电,56.5%为可充电。可充电pg的电池寿命明显更长(平均:82.7个月对38.9个月,p < 0.05),在50、100和150个月时关机的可能性更低。电池寿命在铅线位置、刺激类型或疼痛病因方面没有显著差异。经皮导线有延长电池寿命的趋势,尽管没有统计学意义。结论:与非充电型相比,可充电型pg表现出更高的使用寿命,在大多数情况下应被视为首选。虽然手术和经皮导联都是有效的,但经皮导联系统可以提高电池效率。需要进一步的前瞻性研究来证实这些发现并评估成本效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Battery Life of Pulse Generators in Spinal Cord Stimulation: Analysis and Comparison Between Surgical and Percutaneous Leads in Energy Efficiency.

Battery Life of Pulse Generators in Spinal Cord Stimulation: Analysis and Comparison Between Surgical and Percutaneous Leads in Energy Efficiency.

Battery Life of Pulse Generators in Spinal Cord Stimulation: Analysis and Comparison Between Surgical and Percutaneous Leads in Energy Efficiency.

Battery Life of Pulse Generators in Spinal Cord Stimulation: Analysis and Comparison Between Surgical and Percutaneous Leads in Energy Efficiency.

Background: Spinal cord stimulation (SCS) is an established therapy for chronic neuropathic pain. Although rechargeable and non-rechargeable pulse generators (PGs) are widely used, their real-world battery life and the influence of lead type on energy efficiency remain underexplored. Objective: To evaluate PG battery longevity and compare the performance of surgical versus percutaneous leads in terms of energy efficiency. Methods: We conducted a retrospective study of 283 PGs implanted at Hospital Virgen de las Nieves (Granada, Spain) from 1996 to 2023. Data on patient demographics, pain etiology, lead type and placement, stimulation modality, and PG status were extracted. A competing risks analysis was used to assess PG shutdown and early explantation over time. Results: Of the PGs analyzed, 43.5% were non-rechargeable and 56.5% rechargeable. Rechargeable PGs showed significantly longer battery life (mean: 82.7 vs. 38.9 months, p < 0.05), with a lower probability of shutdown at 50, 100, and 150 months. No significant differences in battery longevity were observed regarding lead location, stimulation type, or pain etiology. A trend toward longer battery life was observed with percutaneous leads, although not statistically significant. Conclusions: Rechargeable PGs demonstrated superior longevity compared to non-rechargeable models and should be considered the preferred option in most cases. While both surgical and percutaneous leads are effective, percutaneous systems may offer improved battery efficiency. Further prospective studies are warranted to confirm these findings and assess cost-effectiveness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Clinical Medicine
Journal of Clinical Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
5.70
自引率
7.70%
发文量
6468
审稿时长
16.32 days
期刊介绍: Journal of Clinical Medicine (ISSN 2077-0383), is an international scientific open access journal, providing a platform for advances in health care/clinical practices, the study of direct observation of patients and general medical research. This multi-disciplinary journal is aimed at a wide audience of medical researchers and healthcare professionals. Unique features of this journal: manuscripts regarding original research and ideas will be particularly welcomed.JCM also accepts reviews, communications, and short notes. There is no limit to publication length: our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信