Behnam Namiranian, Kenichiro Doi, Salem Alenezi, Sameer B Shah, Saeed Jerban, Eric Y Chang
{"title":"动物模型骨评价微有限元分析。","authors":"Behnam Namiranian, Kenichiro Doi, Salem Alenezi, Sameer B Shah, Saeed Jerban, Eric Y Chang","doi":"10.3390/tomography11090101","DOIUrl":null,"url":null,"abstract":"<p><p>Micro-computed tomography (micro-CT) is a commonly used tool for bone evaluation in animal model research. Micro-scale finite element analysis (µFEA) has been proposed to account for different loading scenarios, detailed three-dimensional (3D) bone structure, material properties, and distribution obtained from micro-CT to estimate bone mechanical properties and to predict its potential fracture. The in vivo application of µFEA has been limited to animal models due to the smaller bore size of micro-CT and the long scan time. This narrative review article describes studies that used micro-CT-based µFEA to predict bone mechanical competence, understand bone fracture and remodeling mechanisms, and to evaluate the impacts of the therapeutics, implants, and surgical interventions. Moreover, the concept, limitations, and future potentials of micro-CT-based FEA are discussed.</p>","PeriodicalId":51330,"journal":{"name":"Tomography","volume":"11 9","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473714/pdf/","citationCount":"0","resultStr":"{\"title\":\"Bone Evaluation with Micro Finite Element Analysis in Animal Models.\",\"authors\":\"Behnam Namiranian, Kenichiro Doi, Salem Alenezi, Sameer B Shah, Saeed Jerban, Eric Y Chang\",\"doi\":\"10.3390/tomography11090101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Micro-computed tomography (micro-CT) is a commonly used tool for bone evaluation in animal model research. Micro-scale finite element analysis (µFEA) has been proposed to account for different loading scenarios, detailed three-dimensional (3D) bone structure, material properties, and distribution obtained from micro-CT to estimate bone mechanical properties and to predict its potential fracture. The in vivo application of µFEA has been limited to animal models due to the smaller bore size of micro-CT and the long scan time. This narrative review article describes studies that used micro-CT-based µFEA to predict bone mechanical competence, understand bone fracture and remodeling mechanisms, and to evaluate the impacts of the therapeutics, implants, and surgical interventions. Moreover, the concept, limitations, and future potentials of micro-CT-based FEA are discussed.</p>\",\"PeriodicalId\":51330,\"journal\":{\"name\":\"Tomography\",\"volume\":\"11 9\",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12473714/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tomography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/tomography11090101\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/tomography11090101","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Bone Evaluation with Micro Finite Element Analysis in Animal Models.
Micro-computed tomography (micro-CT) is a commonly used tool for bone evaluation in animal model research. Micro-scale finite element analysis (µFEA) has been proposed to account for different loading scenarios, detailed three-dimensional (3D) bone structure, material properties, and distribution obtained from micro-CT to estimate bone mechanical properties and to predict its potential fracture. The in vivo application of µFEA has been limited to animal models due to the smaller bore size of micro-CT and the long scan time. This narrative review article describes studies that used micro-CT-based µFEA to predict bone mechanical competence, understand bone fracture and remodeling mechanisms, and to evaluate the impacts of the therapeutics, implants, and surgical interventions. Moreover, the concept, limitations, and future potentials of micro-CT-based FEA are discussed.
TomographyMedicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.70
自引率
10.50%
发文量
222
期刊介绍:
TomographyTM publishes basic (technical and pre-clinical) and clinical scientific articles which involve the advancement of imaging technologies. Tomography encompasses studies that use single or multiple imaging modalities including for example CT, US, PET, SPECT, MR and hyperpolarization technologies, as well as optical modalities (i.e. bioluminescence, photoacoustic, endomicroscopy, fiber optic imaging and optical computed tomography) in basic sciences, engineering, preclinical and clinical medicine.
Tomography also welcomes studies involving exploration and refinement of contrast mechanisms and image-derived metrics within and across modalities toward the development of novel imaging probes for image-based feedback and intervention. The use of imaging in biology and medicine provides unparalleled opportunities to noninvasively interrogate tissues to obtain real-time dynamic and quantitative information required for diagnosis and response to interventions and to follow evolving pathological conditions. As multi-modal studies and the complexities of imaging technologies themselves are ever increasing to provide advanced information to scientists and clinicians.
Tomography provides a unique publication venue allowing investigators the opportunity to more precisely communicate integrated findings related to the diverse and heterogeneous features associated with underlying anatomical, physiological, functional, metabolic and molecular genetic activities of normal and diseased tissue. Thus Tomography publishes peer-reviewed articles which involve the broad use of imaging of any tissue and disease type including both preclinical and clinical investigations. In addition, hardware/software along with chemical and molecular probe advances are welcome as they are deemed to significantly contribute towards the long-term goal of improving the overall impact of imaging on scientific and clinical discovery.