建立新生儿和婴儿高敏感心肌肌钙蛋白T参考区间。

IF 3.7 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Yue-Qi Li, Gui-Cheng Ye, Jing-Ying Yang, Gong-Jun Tan
{"title":"建立新生儿和婴儿高敏感心肌肌钙蛋白T参考区间。","authors":"Yue-Qi Li, Gui-Cheng Ye, Jing-Ying Yang, Gong-Jun Tan","doi":"10.1515/cclm-2025-0985","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>High-sensitivity cardiac troponin T (hs-cTnT) is used in pediatric healthcare to diagnose and assess the prognosis of various cardiac diseases, such as acute myocarditis, congenital heart disease, dilated cardiomyopathy, and heart failure. However, the standardized age-related reference intervals, 99th percentile cut-offs, and clinical guidelines are currently unavailable, especially in newborns and infants, making interpreting this biomarker challenging.</p><p><strong>Methods: </strong>Residual serum samples were collected from 1,047 pediatric subjects with no cardiovascular disease, including 145 neonates and 902 infants. The concentrations of hs-cTnT were analyzed using Roche's Elecsys Troponin T hs assay. The age-related 99th percentile cut-offs with 90 % confidence intervals (CIs) of hs-cTnT were established.</p><p><strong>Results: </strong>Subjects were divided into age subgroups as follows: newborns (0-30 days, n=142), infants aged 1 month (31-60 days, n=223), 2 months (61-90 days, n=152), 3-4 months (91-150 days, n=211), 5-6 months (151-210 days, n=149), and 7 months-1 year (211-365 days, n=149). Serum hs-cTnT concentrations were highest during the first month of life and progressively declined in a year. The 99th percentile cut-offs of hs-cTnT concentration in each group were as follows: 114 (90 % CI: 114-114), 65.6 (63.7-66.1), 55.2 (54.4-55.2), 30.4 (29.1-30.9), 23.5 (22.1-23.5), 12.7 (12.4-12.7) ng/L. The 97.5th percentile cut-offs for each group were 109.4 (105.2-114), 62.5 (60.5-63.9), 52.3 (50.3-54.4), 29 (28.5-29.1), 20.5 (19.2-23.4), and 12 (12-12.1) ng/L.</p><p><strong>Conclusions: </strong>This study aimed to provide reliable pediatric reference values for hs-cTnT based on a population of well-child children. These reference intervals and 99th percentile cut-offs will inform clinical decisions in the pediatric cardiology setting.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Establishing reference intervals for high-sensitivity cardiac troponin T in neonates and infants.\",\"authors\":\"Yue-Qi Li, Gui-Cheng Ye, Jing-Ying Yang, Gong-Jun Tan\",\"doi\":\"10.1515/cclm-2025-0985\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>High-sensitivity cardiac troponin T (hs-cTnT) is used in pediatric healthcare to diagnose and assess the prognosis of various cardiac diseases, such as acute myocarditis, congenital heart disease, dilated cardiomyopathy, and heart failure. However, the standardized age-related reference intervals, 99th percentile cut-offs, and clinical guidelines are currently unavailable, especially in newborns and infants, making interpreting this biomarker challenging.</p><p><strong>Methods: </strong>Residual serum samples were collected from 1,047 pediatric subjects with no cardiovascular disease, including 145 neonates and 902 infants. The concentrations of hs-cTnT were analyzed using Roche's Elecsys Troponin T hs assay. The age-related 99th percentile cut-offs with 90 % confidence intervals (CIs) of hs-cTnT were established.</p><p><strong>Results: </strong>Subjects were divided into age subgroups as follows: newborns (0-30 days, n=142), infants aged 1 month (31-60 days, n=223), 2 months (61-90 days, n=152), 3-4 months (91-150 days, n=211), 5-6 months (151-210 days, n=149), and 7 months-1 year (211-365 days, n=149). Serum hs-cTnT concentrations were highest during the first month of life and progressively declined in a year. The 99th percentile cut-offs of hs-cTnT concentration in each group were as follows: 114 (90 % CI: 114-114), 65.6 (63.7-66.1), 55.2 (54.4-55.2), 30.4 (29.1-30.9), 23.5 (22.1-23.5), 12.7 (12.4-12.7) ng/L. The 97.5th percentile cut-offs for each group were 109.4 (105.2-114), 62.5 (60.5-63.9), 52.3 (50.3-54.4), 29 (28.5-29.1), 20.5 (19.2-23.4), and 12 (12-12.1) ng/L.</p><p><strong>Conclusions: </strong>This study aimed to provide reliable pediatric reference values for hs-cTnT based on a population of well-child children. These reference intervals and 99th percentile cut-offs will inform clinical decisions in the pediatric cardiology setting.</p>\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2025-0985\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2025-0985","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:高灵敏度心肌肌钙蛋白T (hs-cTnT)在小儿保健中用于诊断和评估各种心脏疾病的预后,如急性心肌炎、先天性心脏病、扩张型心肌病和心力衰竭。然而,标准化的年龄相关参考区间、第99百分位截断点和临床指南目前尚不可用,特别是在新生儿和婴儿中,这使得解释这一生物标志物具有挑战性。方法:收集1047例无心血管疾病儿童的血清残留样本,其中新生儿145例,婴幼儿902例。使用罗氏的Elecsys肌钙蛋白T测定法分析hs- ctnt的浓度。建立hs-cTnT与年龄相关的第99百分位截断值为90 %置信区间(CIs)。结果:受试者按年龄分组:新生儿(0 ~ 30天,n=142)、1月龄(31 ~ 60天,n=223)、2月龄(61 ~ 90天,n=152)、3 ~ 4月龄(91 ~ 150天,n=211)、5 ~ 6月龄(151 ~ 210天,n=149)、7月龄~ 1岁(211 ~ 365天,n=149)。血清hs-cTnT浓度在出生后的第一个月最高,并在一年内逐渐下降。各组hs-cTnT浓度的第99百分位截断值分别为114(90 % CI: 114-114)、65.6(63.7-66.1)、55.2(54.4-55.2)、30.4(29.1-30.9)、23.5(22.1-23.5)、12.7 (12.4-12.7)ng/L。各组的97.5百分位截断值分别为109.4(105.2-114)、62.5(60.5-63.9)、52.3(50.3-54.4)、29(28.5-29.1)、20.5(19.2-23.4)和12 (12-12.1)ng/L。结论:本研究旨在为基于健康儿童人群的hs-cTnT提供可靠的儿科参考值。这些参考区间和99个百分位数的截止值将为儿科心脏病学设置的临床决策提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Establishing reference intervals for high-sensitivity cardiac troponin T in neonates and infants.

Objectives: High-sensitivity cardiac troponin T (hs-cTnT) is used in pediatric healthcare to diagnose and assess the prognosis of various cardiac diseases, such as acute myocarditis, congenital heart disease, dilated cardiomyopathy, and heart failure. However, the standardized age-related reference intervals, 99th percentile cut-offs, and clinical guidelines are currently unavailable, especially in newborns and infants, making interpreting this biomarker challenging.

Methods: Residual serum samples were collected from 1,047 pediatric subjects with no cardiovascular disease, including 145 neonates and 902 infants. The concentrations of hs-cTnT were analyzed using Roche's Elecsys Troponin T hs assay. The age-related 99th percentile cut-offs with 90 % confidence intervals (CIs) of hs-cTnT were established.

Results: Subjects were divided into age subgroups as follows: newborns (0-30 days, n=142), infants aged 1 month (31-60 days, n=223), 2 months (61-90 days, n=152), 3-4 months (91-150 days, n=211), 5-6 months (151-210 days, n=149), and 7 months-1 year (211-365 days, n=149). Serum hs-cTnT concentrations were highest during the first month of life and progressively declined in a year. The 99th percentile cut-offs of hs-cTnT concentration in each group were as follows: 114 (90 % CI: 114-114), 65.6 (63.7-66.1), 55.2 (54.4-55.2), 30.4 (29.1-30.9), 23.5 (22.1-23.5), 12.7 (12.4-12.7) ng/L. The 97.5th percentile cut-offs for each group were 109.4 (105.2-114), 62.5 (60.5-63.9), 52.3 (50.3-54.4), 29 (28.5-29.1), 20.5 (19.2-23.4), and 12 (12-12.1) ng/L.

Conclusions: This study aimed to provide reliable pediatric reference values for hs-cTnT based on a population of well-child children. These reference intervals and 99th percentile cut-offs will inform clinical decisions in the pediatric cardiology setting.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信