{"title":"噪声增强深度去噪:一种增强CT图像去噪网络的方法。","authors":"Gernot Kristof, Elias Eulig, Marc Kachelrieß","doi":"10.1002/mp.18121","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Denoising low dose computed tomography (CT) images can have great advantages for the aim of minimizing the radiation risk of the patients, as it can help lower the effective dose to the patient while providing constant image quality. In recent years, deep denoising methods became a popular way to accomplish this task. Conventional deep denoising algorithms, however, cannot handle the correlation between neighboring pixels or voxels very well, because the noise structure in CT is a resultant of the global attenuation properties of the patient and because the receptive field of most denoising approaches is rather small.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>The purpose of this study is to improve existing denoising networks, by providing them additional information about the image noise.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We here propose to generate <span></span><math>\n <semantics>\n <mi>N</mi>\n <annotation>$N$</annotation>\n </semantics></math> additional noise realizations by simulation, reconstruct them, and use these noise images as additional input into existing denoising networks. This noise augmentation is intended to guide the denoising process. The additional noise realizations are not only required during training, but also during inference. The rationale behind this noise-augmented deep denoising (NADD) is that CT image noise is strongly patient-specific and it is non-local since it depends on the attenuation of X-ray beams. NADD is architecture-agnostic and can thus be used to improve any previously proposed method. We demonstrate NADD using existing denoising networks that we slightly modified in their input layer in order to take the CT image that is to be denoised plus additional noise images as input. To do so, we modified three popular denoising networks, the CNN10, the ResNet, and the WGAN-VGG and apply them to clinical cases with 90% dose reduction.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In all cases tested, the denoising networks strongly benefit from the noise augmentation. Noise artifacts that are being misinterpreted by the original networks as being anatomical structures, are correctly removed by the NADD version of the same networks. The more noise images are provided, the better the performance.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Providing additional simulated noise realizations helps to significantly improve the performance of CT image denoising networks.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"52 10","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://aapm.onlinelibrary.wiley.com/doi/epdf/10.1002/mp.18121","citationCount":"0","resultStr":"{\"title\":\"Noise-augmented deep denoising: A method to boost CT image denoising networks\",\"authors\":\"Gernot Kristof, Elias Eulig, Marc Kachelrieß\",\"doi\":\"10.1002/mp.18121\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Denoising low dose computed tomography (CT) images can have great advantages for the aim of minimizing the radiation risk of the patients, as it can help lower the effective dose to the patient while providing constant image quality. In recent years, deep denoising methods became a popular way to accomplish this task. Conventional deep denoising algorithms, however, cannot handle the correlation between neighboring pixels or voxels very well, because the noise structure in CT is a resultant of the global attenuation properties of the patient and because the receptive field of most denoising approaches is rather small.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>The purpose of this study is to improve existing denoising networks, by providing them additional information about the image noise.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We here propose to generate <span></span><math>\\n <semantics>\\n <mi>N</mi>\\n <annotation>$N$</annotation>\\n </semantics></math> additional noise realizations by simulation, reconstruct them, and use these noise images as additional input into existing denoising networks. This noise augmentation is intended to guide the denoising process. The additional noise realizations are not only required during training, but also during inference. The rationale behind this noise-augmented deep denoising (NADD) is that CT image noise is strongly patient-specific and it is non-local since it depends on the attenuation of X-ray beams. NADD is architecture-agnostic and can thus be used to improve any previously proposed method. We demonstrate NADD using existing denoising networks that we slightly modified in their input layer in order to take the CT image that is to be denoised plus additional noise images as input. To do so, we modified three popular denoising networks, the CNN10, the ResNet, and the WGAN-VGG and apply them to clinical cases with 90% dose reduction.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>In all cases tested, the denoising networks strongly benefit from the noise augmentation. Noise artifacts that are being misinterpreted by the original networks as being anatomical structures, are correctly removed by the NADD version of the same networks. The more noise images are provided, the better the performance.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Providing additional simulated noise realizations helps to significantly improve the performance of CT image denoising networks.</p>\\n </section>\\n </div>\",\"PeriodicalId\":18384,\"journal\":{\"name\":\"Medical physics\",\"volume\":\"52 10\",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://aapm.onlinelibrary.wiley.com/doi/epdf/10.1002/mp.18121\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.18121\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.18121","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Noise-augmented deep denoising: A method to boost CT image denoising networks
Background
Denoising low dose computed tomography (CT) images can have great advantages for the aim of minimizing the radiation risk of the patients, as it can help lower the effective dose to the patient while providing constant image quality. In recent years, deep denoising methods became a popular way to accomplish this task. Conventional deep denoising algorithms, however, cannot handle the correlation between neighboring pixels or voxels very well, because the noise structure in CT is a resultant of the global attenuation properties of the patient and because the receptive field of most denoising approaches is rather small.
Purpose
The purpose of this study is to improve existing denoising networks, by providing them additional information about the image noise.
Methods
We here propose to generate additional noise realizations by simulation, reconstruct them, and use these noise images as additional input into existing denoising networks. This noise augmentation is intended to guide the denoising process. The additional noise realizations are not only required during training, but also during inference. The rationale behind this noise-augmented deep denoising (NADD) is that CT image noise is strongly patient-specific and it is non-local since it depends on the attenuation of X-ray beams. NADD is architecture-agnostic and can thus be used to improve any previously proposed method. We demonstrate NADD using existing denoising networks that we slightly modified in their input layer in order to take the CT image that is to be denoised plus additional noise images as input. To do so, we modified three popular denoising networks, the CNN10, the ResNet, and the WGAN-VGG and apply them to clinical cases with 90% dose reduction.
Results
In all cases tested, the denoising networks strongly benefit from the noise augmentation. Noise artifacts that are being misinterpreted by the original networks as being anatomical structures, are correctly removed by the NADD version of the same networks. The more noise images are provided, the better the performance.
Conclusions
Providing additional simulated noise realizations helps to significantly improve the performance of CT image denoising networks.
期刊介绍:
Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments
Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.