连续血糖监测对老年2型糖尿病患者的可用性:系统评价。

IF 6.3 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM
April Savoy, Cristina Barboi, Melissa R Thomas, Michael Weiner
{"title":"连续血糖监测对老年2型糖尿病患者的可用性:系统评价。","authors":"April Savoy, Cristina Barboi, Melissa R Thomas, Michael Weiner","doi":"10.1177/15209156251369021","DOIUrl":null,"url":null,"abstract":"<p><p>This systematic review aims to examine the use and usability of continuous glucose monitoring (CGM) among older adults with type 2 diabetes mellitus. The following databases, PubMed, Embase, and CINAHL, were searched for studies published between 2019 and 2024, and results were documented using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Eligibility criteria included English-language studies that researched the use and usability of CGM in adults 60 years or older with a minimum wear time of 2 weeks. We extracted usability (efficiency, effectiveness, and satisfaction) outcomes. Study quality was assessed using the Critical Appraisal Skills Program Checklist. Of the 118 identified titles, 58 articles underwent a full-text review, with seven being included in the final analysis. Studies evaluated clinical management of type 2 diabetes with CGM, assessing the following differences: CGM versus usual care, CGM across device types, and CGM across care models. Clinical effectiveness, based on glycated hemoglobin and time-in-range, and satisfaction were higher across CGM types compared with usual care. Based on descriptive measures, satisfaction was higher with real-time CGM than professional-mode CGM. Efficiency findings were not reported in the included studies. There were no findings on the effectiveness, efficiency, and satisfaction of ambulatory glucose profile (AGP) metrics. Although the clinical effectiveness of CGM among adults 60 years or older was demonstrated in the reviewed studies, our usability assessment is inconclusive. There is a gap in evidence related to the essential components that comprise the context of CGM use, which prohibits a complete usability assessment. Future studies are warranted to investigate CGM usability, emphasizing AGP metrics, to inform improvements and personalization for older adults.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":""},"PeriodicalIF":6.3000,"publicationDate":"2025-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Usability of Continuous Glucose Monitoring for Older Adults with Type 2 Diabetes: A Systematic Review.\",\"authors\":\"April Savoy, Cristina Barboi, Melissa R Thomas, Michael Weiner\",\"doi\":\"10.1177/15209156251369021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This systematic review aims to examine the use and usability of continuous glucose monitoring (CGM) among older adults with type 2 diabetes mellitus. The following databases, PubMed, Embase, and CINAHL, were searched for studies published between 2019 and 2024, and results were documented using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Eligibility criteria included English-language studies that researched the use and usability of CGM in adults 60 years or older with a minimum wear time of 2 weeks. We extracted usability (efficiency, effectiveness, and satisfaction) outcomes. Study quality was assessed using the Critical Appraisal Skills Program Checklist. Of the 118 identified titles, 58 articles underwent a full-text review, with seven being included in the final analysis. Studies evaluated clinical management of type 2 diabetes with CGM, assessing the following differences: CGM versus usual care, CGM across device types, and CGM across care models. Clinical effectiveness, based on glycated hemoglobin and time-in-range, and satisfaction were higher across CGM types compared with usual care. Based on descriptive measures, satisfaction was higher with real-time CGM than professional-mode CGM. Efficiency findings were not reported in the included studies. There were no findings on the effectiveness, efficiency, and satisfaction of ambulatory glucose profile (AGP) metrics. Although the clinical effectiveness of CGM among adults 60 years or older was demonstrated in the reviewed studies, our usability assessment is inconclusive. There is a gap in evidence related to the essential components that comprise the context of CGM use, which prohibits a complete usability assessment. Future studies are warranted to investigate CGM usability, emphasizing AGP metrics, to inform improvements and personalization for older adults.</p>\",\"PeriodicalId\":11159,\"journal\":{\"name\":\"Diabetes technology & therapeutics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":6.3000,\"publicationDate\":\"2025-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes technology & therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15209156251369021\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15209156251369021","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

本系统综述旨在探讨连续血糖监测(CGM)在老年2型糖尿病患者中的使用和可用性。检索了以下数据库:PubMed、Embase和CINAHL,检索了2019年至2024年间发表的研究,并使用系统评价和荟萃分析首选报告项目清单记录了结果。资格标准包括英语研究,研究60岁或以上的成年人使用和可用性CGM,最小佩戴时间为2周。我们提取了可用性(效率、有效性和满意度)结果。使用关键评估技能项目检查表评估研究质量。在确定的118个标题中,58篇文章进行了全文审查,其中7篇被纳入最终分析。研究评估了2型糖尿病合并CGM的临床管理,评估了以下差异:CGM与常规护理、不同设备类型的CGM、不同护理模式的CGM。与常规护理相比,基于糖化血红蛋白和时间范围的临床疗效和满意度在所有CGM类型中都更高。基于描述性测量,实时CGM的满意度高于专业模式CGM。在纳入的研究中未报告效率方面的发现。没有关于动态葡萄糖谱(AGP)指标的有效性、效率和满意度的研究结果。虽然CGM在60岁或以上的成年人中的临床有效性在回顾的研究中得到证实,但我们的可用性评估尚无定论。与构成CGM使用背景的基本组件相关的证据存在差距,这妨碍了完整的可用性评估。未来的研究有必要调查CGM的可用性,强调AGP指标,为老年人的改进和个性化提供信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Usability of Continuous Glucose Monitoring for Older Adults with Type 2 Diabetes: A Systematic Review.

This systematic review aims to examine the use and usability of continuous glucose monitoring (CGM) among older adults with type 2 diabetes mellitus. The following databases, PubMed, Embase, and CINAHL, were searched for studies published between 2019 and 2024, and results were documented using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Eligibility criteria included English-language studies that researched the use and usability of CGM in adults 60 years or older with a minimum wear time of 2 weeks. We extracted usability (efficiency, effectiveness, and satisfaction) outcomes. Study quality was assessed using the Critical Appraisal Skills Program Checklist. Of the 118 identified titles, 58 articles underwent a full-text review, with seven being included in the final analysis. Studies evaluated clinical management of type 2 diabetes with CGM, assessing the following differences: CGM versus usual care, CGM across device types, and CGM across care models. Clinical effectiveness, based on glycated hemoglobin and time-in-range, and satisfaction were higher across CGM types compared with usual care. Based on descriptive measures, satisfaction was higher with real-time CGM than professional-mode CGM. Efficiency findings were not reported in the included studies. There were no findings on the effectiveness, efficiency, and satisfaction of ambulatory glucose profile (AGP) metrics. Although the clinical effectiveness of CGM among adults 60 years or older was demonstrated in the reviewed studies, our usability assessment is inconclusive. There is a gap in evidence related to the essential components that comprise the context of CGM use, which prohibits a complete usability assessment. Future studies are warranted to investigate CGM usability, emphasizing AGP metrics, to inform improvements and personalization for older adults.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信