{"title":"关节镜下肩胛骨骨块“钻石”固定治疗复发性肩关节前不稳定伴亚临界盂骨丢失的功能和影像学结果","authors":"Abdul-ilah Hachem MD , Diego Gonzalez-Morgado MD, PhD , Gonzalo Barraza MD , Fernando Alvarado MD , Alvaro Minuesa-Madruga MD , Xavi Rius MD","doi":"10.1016/j.jseint.2025.05.016","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Arthroscopic glenoid reconstruction with free bone blocks reduces recurrence in anterior shoulder instability. The scapular spine bone block has been described to address subcritical glenoid bone loss (GBL), though its clinical outcomes are still unclear. This study aimed to report the functional and radiological outcomes of patients with anterior shoulder instability and GBL <15% who underwent arthroscopic glenoid reconstruction using a scapular spine bone block fixed with knotless suture anchors in a “diamond” configuration.</div></div><div><h3>Methods</h3><div>A tricortical spine bone graft was harvested. Two knotless all-suture anchors were centrally placed at the glenoid defect. Each anchor included 1 suture for repair and another for transport. The repairs suture from the anchors were interconnected through two holes, creating a bridge over the graft tunnels. The remaining suture limbs were inserted into a third knotless anchor midway between the initial two, establishing a stable configuration for secure fixation. Range of motion, patient-reported outcomes, return to sport, instability recurrence, complications, and reintervention were assessed at a minimum 2 years postoperatively. The glenoid surface area was measured preoperatively, postoperatively, and at a 2-year follow-up, with graft resorption evaluated at a 2-year follow-up.</div></div><div><h3>Results</h3><div>Three patients were included. The GBL ranged from 8% to 13%. Range of motion was similar between sides at the 2-year follow-up. Patients scored higher in patient-reported outcomes from baseline to the 1-year and 2-year follow-ups. All patients returned to sports within 8 months. No recurrent instability or reinterventions occurred. At 3 months postoperatively, all patients achieved graft union, with complete glenoid surface area remodeling at 2-year follow-up.</div></div><div><h3>Conclusion</h3><div>Arthroscopic scapular spine bone block fixation using knotless suture anchors in a “diamond” configuration is effective and safe for treating recurrent anterior shoulder instability with <15% GBL, facilitating an early return to sports.</div></div>","PeriodicalId":34444,"journal":{"name":"JSES International","volume":"9 5","pages":"Pages 1449-1456"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Functional and radiological outcomes of arthroscopic scapular spine bone block “diamond” fixation for recurrent anterior shoulder instability with subcritical glenoid bone loss\",\"authors\":\"Abdul-ilah Hachem MD , Diego Gonzalez-Morgado MD, PhD , Gonzalo Barraza MD , Fernando Alvarado MD , Alvaro Minuesa-Madruga MD , Xavi Rius MD\",\"doi\":\"10.1016/j.jseint.2025.05.016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Arthroscopic glenoid reconstruction with free bone blocks reduces recurrence in anterior shoulder instability. The scapular spine bone block has been described to address subcritical glenoid bone loss (GBL), though its clinical outcomes are still unclear. This study aimed to report the functional and radiological outcomes of patients with anterior shoulder instability and GBL <15% who underwent arthroscopic glenoid reconstruction using a scapular spine bone block fixed with knotless suture anchors in a “diamond” configuration.</div></div><div><h3>Methods</h3><div>A tricortical spine bone graft was harvested. Two knotless all-suture anchors were centrally placed at the glenoid defect. Each anchor included 1 suture for repair and another for transport. The repairs suture from the anchors were interconnected through two holes, creating a bridge over the graft tunnels. The remaining suture limbs were inserted into a third knotless anchor midway between the initial two, establishing a stable configuration for secure fixation. Range of motion, patient-reported outcomes, return to sport, instability recurrence, complications, and reintervention were assessed at a minimum 2 years postoperatively. The glenoid surface area was measured preoperatively, postoperatively, and at a 2-year follow-up, with graft resorption evaluated at a 2-year follow-up.</div></div><div><h3>Results</h3><div>Three patients were included. The GBL ranged from 8% to 13%. Range of motion was similar between sides at the 2-year follow-up. Patients scored higher in patient-reported outcomes from baseline to the 1-year and 2-year follow-ups. All patients returned to sports within 8 months. No recurrent instability or reinterventions occurred. At 3 months postoperatively, all patients achieved graft union, with complete glenoid surface area remodeling at 2-year follow-up.</div></div><div><h3>Conclusion</h3><div>Arthroscopic scapular spine bone block fixation using knotless suture anchors in a “diamond” configuration is effective and safe for treating recurrent anterior shoulder instability with <15% GBL, facilitating an early return to sports.</div></div>\",\"PeriodicalId\":34444,\"journal\":{\"name\":\"JSES International\",\"volume\":\"9 5\",\"pages\":\"Pages 1449-1456\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JSES International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S266663832500180X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSES International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S266663832500180X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Functional and radiological outcomes of arthroscopic scapular spine bone block “diamond” fixation for recurrent anterior shoulder instability with subcritical glenoid bone loss
Background
Arthroscopic glenoid reconstruction with free bone blocks reduces recurrence in anterior shoulder instability. The scapular spine bone block has been described to address subcritical glenoid bone loss (GBL), though its clinical outcomes are still unclear. This study aimed to report the functional and radiological outcomes of patients with anterior shoulder instability and GBL <15% who underwent arthroscopic glenoid reconstruction using a scapular spine bone block fixed with knotless suture anchors in a “diamond” configuration.
Methods
A tricortical spine bone graft was harvested. Two knotless all-suture anchors were centrally placed at the glenoid defect. Each anchor included 1 suture for repair and another for transport. The repairs suture from the anchors were interconnected through two holes, creating a bridge over the graft tunnels. The remaining suture limbs were inserted into a third knotless anchor midway between the initial two, establishing a stable configuration for secure fixation. Range of motion, patient-reported outcomes, return to sport, instability recurrence, complications, and reintervention were assessed at a minimum 2 years postoperatively. The glenoid surface area was measured preoperatively, postoperatively, and at a 2-year follow-up, with graft resorption evaluated at a 2-year follow-up.
Results
Three patients were included. The GBL ranged from 8% to 13%. Range of motion was similar between sides at the 2-year follow-up. Patients scored higher in patient-reported outcomes from baseline to the 1-year and 2-year follow-ups. All patients returned to sports within 8 months. No recurrent instability or reinterventions occurred. At 3 months postoperatively, all patients achieved graft union, with complete glenoid surface area remodeling at 2-year follow-up.
Conclusion
Arthroscopic scapular spine bone block fixation using knotless suture anchors in a “diamond” configuration is effective and safe for treating recurrent anterior shoulder instability with <15% GBL, facilitating an early return to sports.