固定源二氯甲烷排放测定方法的发展。

F E Butler, E A Coppedge, J C Suggs, J E Knoll, M R Midgett, A L Sykes, M W Hartman, J L Steger
{"title":"固定源二氯甲烷排放测定方法的发展。","authors":"F E Butler, E A Coppedge, J C Suggs, J E Knoll, M R Midgett, A L Sykes, M W Hartman, J L Steger","doi":"10.1080/08940630.1988.10466378","DOIUrl":null,"url":null,"abstract":"Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH/sub 2/Cl/sub 2/ remained stable in Tedlar bags for at least four weeks. The analytical method selected was gas chromatography with flame ionization detection (GC/FID). During the field portion of the study, both manufacturer and user emissions sources of CH/sub 2/Cl/sub 2/ were tested. Multiple sets of simultaneous quadruplicate bag samples were collected to determine the precision of both sampling and analysis in the field. All samples were analyzed at the test site after collection and then returned to Research Triangle Park. Samples were subsequently reanalyzed in the laboratories of Radian and the US EPA using three GC/FID instruments and two types of GC columns. The range of concentrations from the sources was 100 ppm to 27,000 ppm CH/sub 2/Cl/sub 2/. A statistical analysis of samples collected simultaneously showed no difference in the samples, proving good precision in both sampling and analysis. Some of the sample bags returned from the test sites developed leaks indicating that immediate on-site analysis is best. A comparison of results obtained in the field and the two laboratories showed thatmore » inter- and intra-laboratory precision was within 10%.« less","PeriodicalId":77731,"journal":{"name":"JAPCA","volume":"38 3","pages":"272-7"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/08940630.1988.10466378","citationCount":"1","resultStr":"{\"title\":\"Development of a method for determination of methylene chloride emissions at stationary sources.\",\"authors\":\"F E Butler, E A Coppedge, J C Suggs, J E Knoll, M R Midgett, A L Sykes, M W Hartman, J L Steger\",\"doi\":\"10.1080/08940630.1988.10466378\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH/sub 2/Cl/sub 2/ remained stable in Tedlar bags for at least four weeks. The analytical method selected was gas chromatography with flame ionization detection (GC/FID). During the field portion of the study, both manufacturer and user emissions sources of CH/sub 2/Cl/sub 2/ were tested. Multiple sets of simultaneous quadruplicate bag samples were collected to determine the precision of both sampling and analysis in the field. All samples were analyzed at the test site after collection and then returned to Research Triangle Park. Samples were subsequently reanalyzed in the laboratories of Radian and the US EPA using three GC/FID instruments and two types of GC columns. The range of concentrations from the sources was 100 ppm to 27,000 ppm CH/sub 2/Cl/sub 2/. A statistical analysis of samples collected simultaneously showed no difference in the samples, proving good precision in both sampling and analysis. Some of the sample bags returned from the test sites developed leaks indicating that immediate on-site analysis is best. A comparison of results obtained in the field and the two laboratories showed thatmore » inter- and intra-laboratory precision was within 10%.« less\",\"PeriodicalId\":77731,\"journal\":{\"name\":\"JAPCA\",\"volume\":\"38 3\",\"pages\":\"272-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/08940630.1988.10466378\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JAPCA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/08940630.1988.10466378\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAPCA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08940630.1988.10466378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a method for determination of methylene chloride emissions at stationary sources.
Prior to source sampling, laboratory experiments were conducted to determine the best sample container in which to collect an integrated sample. It was found that CH/sub 2/Cl/sub 2/ remained stable in Tedlar bags for at least four weeks. The analytical method selected was gas chromatography with flame ionization detection (GC/FID). During the field portion of the study, both manufacturer and user emissions sources of CH/sub 2/Cl/sub 2/ were tested. Multiple sets of simultaneous quadruplicate bag samples were collected to determine the precision of both sampling and analysis in the field. All samples were analyzed at the test site after collection and then returned to Research Triangle Park. Samples were subsequently reanalyzed in the laboratories of Radian and the US EPA using three GC/FID instruments and two types of GC columns. The range of concentrations from the sources was 100 ppm to 27,000 ppm CH/sub 2/Cl/sub 2/. A statistical analysis of samples collected simultaneously showed no difference in the samples, proving good precision in both sampling and analysis. Some of the sample bags returned from the test sites developed leaks indicating that immediate on-site analysis is best. A comparison of results obtained in the field and the two laboratories showed thatmore » inter- and intra-laboratory precision was within 10%.« less
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信