Giulio Lovatti, Munetaka Nitta, Francesco Evangelista, Daria Boscolo, Daria Kostyleva, Mohammad Javad Safari, George Dedes, Chiara Gianoli, Beatrice Foglia, Marco Pinto, Han Gyu Kang, Sivaji Purushothaman, Emma Haettner, Christoph Schuy, Christian Graeff, Ulrich Weber, Christoph Scheidenberger, Peter G Thirolf, Taiga Yamaya, Marco Durante, Katia Parodi
{"title":"用于放射性离子束在线成像的新型PET检测器组件的实验评估。","authors":"Giulio Lovatti, Munetaka Nitta, Francesco Evangelista, Daria Boscolo, Daria Kostyleva, Mohammad Javad Safari, George Dedes, Chiara Gianoli, Beatrice Foglia, Marco Pinto, Han Gyu Kang, Sivaji Purushothaman, Emma Haettner, Christoph Schuy, Christian Graeff, Ulrich Weber, Christoph Scheidenberger, Peter G Thirolf, Taiga Yamaya, Marco Durante, Katia Parodi","doi":"10.1088/1361-6560/ae0674","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>This work aims to evaluate the ability of novel detector components to measure with submillimeter resolution in beam positron emission tomography (PET) signals produced by<sup>10</sup>C and<sup>11</sup>C radioactive ion beams stopped in PMMA targets and to validate a simulation toolkit for reproducing beam physics and PET detector responses within the framework of the biomedical applications of radioactive ion beam (BARB) project.<i>Approach.</i>The PET system response was assessed by visualizing the radioactive distributions of the beams stopped in tissue surrogate phantoms, and the capacity of the simulation toolkit was evaluated by comparing the experimental results with simulations, both for the depth-dose distribution and PET imaging.<i>Main results.</i>The detector assembly accurately visualized the PET signal with submillimeter resolution, achieving the objective of measuring the difference in the positron range between<sup>10</sup>C and<sup>11</sup>C. The simulation toolkit effectively reproduced the beam characteristics and detector responses, showing a high degree of agreement between the simulated and experimental PET profiles under different beam delivery conditions.<i>Significance.</i>These findings demonstrate the precision and reliability of the novel in-beam PET detector technology and simulation toolkit for small animals, establishing a solid foundation for the second phase of the BARB project, which involves preclinical irradiation of living mice.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental assessment of novel PET detector components for online imaging of radioactive ion beams.\",\"authors\":\"Giulio Lovatti, Munetaka Nitta, Francesco Evangelista, Daria Boscolo, Daria Kostyleva, Mohammad Javad Safari, George Dedes, Chiara Gianoli, Beatrice Foglia, Marco Pinto, Han Gyu Kang, Sivaji Purushothaman, Emma Haettner, Christoph Schuy, Christian Graeff, Ulrich Weber, Christoph Scheidenberger, Peter G Thirolf, Taiga Yamaya, Marco Durante, Katia Parodi\",\"doi\":\"10.1088/1361-6560/ae0674\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objective.</i>This work aims to evaluate the ability of novel detector components to measure with submillimeter resolution in beam positron emission tomography (PET) signals produced by<sup>10</sup>C and<sup>11</sup>C radioactive ion beams stopped in PMMA targets and to validate a simulation toolkit for reproducing beam physics and PET detector responses within the framework of the biomedical applications of radioactive ion beam (BARB) project.<i>Approach.</i>The PET system response was assessed by visualizing the radioactive distributions of the beams stopped in tissue surrogate phantoms, and the capacity of the simulation toolkit was evaluated by comparing the experimental results with simulations, both for the depth-dose distribution and PET imaging.<i>Main results.</i>The detector assembly accurately visualized the PET signal with submillimeter resolution, achieving the objective of measuring the difference in the positron range between<sup>10</sup>C and<sup>11</sup>C. The simulation toolkit effectively reproduced the beam characteristics and detector responses, showing a high degree of agreement between the simulated and experimental PET profiles under different beam delivery conditions.<i>Significance.</i>These findings demonstrate the precision and reliability of the novel in-beam PET detector technology and simulation toolkit for small animals, establishing a solid foundation for the second phase of the BARB project, which involves preclinical irradiation of living mice.</p>\",\"PeriodicalId\":20185,\"journal\":{\"name\":\"Physics in medicine and biology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2025-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physics in medicine and biology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6560/ae0674\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ae0674","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Experimental assessment of novel PET detector components for online imaging of radioactive ion beams.
Objective.This work aims to evaluate the ability of novel detector components to measure with submillimeter resolution in beam positron emission tomography (PET) signals produced by10C and11C radioactive ion beams stopped in PMMA targets and to validate a simulation toolkit for reproducing beam physics and PET detector responses within the framework of the biomedical applications of radioactive ion beam (BARB) project.Approach.The PET system response was assessed by visualizing the radioactive distributions of the beams stopped in tissue surrogate phantoms, and the capacity of the simulation toolkit was evaluated by comparing the experimental results with simulations, both for the depth-dose distribution and PET imaging.Main results.The detector assembly accurately visualized the PET signal with submillimeter resolution, achieving the objective of measuring the difference in the positron range between10C and11C. The simulation toolkit effectively reproduced the beam characteristics and detector responses, showing a high degree of agreement between the simulated and experimental PET profiles under different beam delivery conditions.Significance.These findings demonstrate the precision and reliability of the novel in-beam PET detector technology and simulation toolkit for small animals, establishing a solid foundation for the second phase of the BARB project, which involves preclinical irradiation of living mice.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry