直立0.5 T开放式MR排便直肠造影概念验证研究:坐式直肠造影骨盆底测量的内部和内部变异性。

IF 2.5 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Rashed Sobhan, Paul M Glover, Penny A Gowland, Rahul Munyal, Olivier E Mougin, Christopher G D Clarke
{"title":"直立0.5 T开放式MR排便直肠造影概念验证研究:坐式直肠造影骨盆底测量的内部和内部变异性。","authors":"Rashed Sobhan, Paul M Glover, Penny A Gowland, Rahul Munyal, Olivier E Mougin, Christopher G D Clarke","doi":"10.1007/s10334-025-01296-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>We tested the feasibility, data quality, and reliability of an upright magnetic resonance defaecating proctography (uMRDP) technique using an Open 0.5 T ASG MRI scanner.</p><p><strong>Materials and methods: </strong>Eight healthy volunteers (2 males) performed seated defaecation on a purpose-built radio-frequency commode coil in an Open scanner. An optimised T2-weighted HASTE sequence captured dynamic changes during all three phases of the Kegel manoeuvre. Inter- and intra-rater variability was measured from the pelvic floor (PF) metrices (M-line, H-line, distances of landmarks) extracted by two radiologists.</p><p><strong>Results: </strong>All relevant PF landmarks could be identified and metrices were extracted with acceptable inter- and intra-rater variability. Intra-rater variation was marginal, with relative absolute differences ranging from 5 to 21% and 3.2-44%. Inter-rater variability was reported using correlation and Bland-Altman plots. Correlation between raters was satisfactory, with r<sup>2</sup> > 0.93, and bias ranged from - 1.8 to 0.65 mm. Moreover, the limit of agreement in the Bland-Altman plot ranged from 5.8 to 20.4 mm, indicating satisfactory precision.</p><p><strong>Discussion: </strong>The proposed uMRDP technique can be used as a feasible and reliable alternative to supine MRDP, without the necessity of gadolinium injection and bowel preparation. It can capture defaecation in a regular seated posture and can provide information complementary to standard-of-care fluoroscopic proctography for clinicians.</p>","PeriodicalId":18067,"journal":{"name":"Magnetic Resonance Materials in Physics, Biology and Medicine","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2025-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Upright 0.5 T open MR defaecating proctography proof of concept study: the inter- and intra-rater variability of pelvic floor measures using seated proctography.\",\"authors\":\"Rashed Sobhan, Paul M Glover, Penny A Gowland, Rahul Munyal, Olivier E Mougin, Christopher G D Clarke\",\"doi\":\"10.1007/s10334-025-01296-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>We tested the feasibility, data quality, and reliability of an upright magnetic resonance defaecating proctography (uMRDP) technique using an Open 0.5 T ASG MRI scanner.</p><p><strong>Materials and methods: </strong>Eight healthy volunteers (2 males) performed seated defaecation on a purpose-built radio-frequency commode coil in an Open scanner. An optimised T2-weighted HASTE sequence captured dynamic changes during all three phases of the Kegel manoeuvre. Inter- and intra-rater variability was measured from the pelvic floor (PF) metrices (M-line, H-line, distances of landmarks) extracted by two radiologists.</p><p><strong>Results: </strong>All relevant PF landmarks could be identified and metrices were extracted with acceptable inter- and intra-rater variability. Intra-rater variation was marginal, with relative absolute differences ranging from 5 to 21% and 3.2-44%. Inter-rater variability was reported using correlation and Bland-Altman plots. Correlation between raters was satisfactory, with r<sup>2</sup> > 0.93, and bias ranged from - 1.8 to 0.65 mm. Moreover, the limit of agreement in the Bland-Altman plot ranged from 5.8 to 20.4 mm, indicating satisfactory precision.</p><p><strong>Discussion: </strong>The proposed uMRDP technique can be used as a feasible and reliable alternative to supine MRDP, without the necessity of gadolinium injection and bowel preparation. It can capture defaecation in a regular seated posture and can provide information complementary to standard-of-care fluoroscopic proctography for clinicians.</p>\",\"PeriodicalId\":18067,\"journal\":{\"name\":\"Magnetic Resonance Materials in Physics, Biology and Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance Materials in Physics, Biology and Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10334-025-01296-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance Materials in Physics, Biology and Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10334-025-01296-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们使用Open 0.5 T ASG MRI扫描仪测试直立式磁共振排便直肠造影(uMRDP)技术的可行性、数据质量和可靠性。材料和方法:8名健康志愿者(2名男性)在开放式扫描仪中对特制的射频马桶线圈进行坐姿排便。一个优化的t2加权匆忙序列捕获动态变化在所有三个阶段的凯格尔演习。通过两名放射科医生提取的骨盆底(PF)尺寸(m线、h线、地标距离)测量盆底间和盆底内变异性。结果:所有相关的PF标志都可以被识别出来,并以可接受的比率间和比率内变异性提取了度量。组内差异较小,相对绝对差异在5% ~ 21%和3.2% ~ 44%之间。利用相关图和Bland-Altman图报告了各因子间的变异。评分者之间的相关性令人满意,r2为0.93,偏差范围为- 1.8至0.65 mm。此外,Bland-Altman图的一致性限制在5.8到20.4 mm之间,表明精度令人满意。讨论:提议的uMRDP技术可以作为仰卧MRDP的可行和可靠的替代方案,无需注射钆和肠准备。它可以在正常的坐姿中捕捉粪便,并可以为临床医生提供标准护理透视直肠造影的补充信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Upright 0.5 T open MR defaecating proctography proof of concept study: the inter- and intra-rater variability of pelvic floor measures using seated proctography.

Objective: We tested the feasibility, data quality, and reliability of an upright magnetic resonance defaecating proctography (uMRDP) technique using an Open 0.5 T ASG MRI scanner.

Materials and methods: Eight healthy volunteers (2 males) performed seated defaecation on a purpose-built radio-frequency commode coil in an Open scanner. An optimised T2-weighted HASTE sequence captured dynamic changes during all three phases of the Kegel manoeuvre. Inter- and intra-rater variability was measured from the pelvic floor (PF) metrices (M-line, H-line, distances of landmarks) extracted by two radiologists.

Results: All relevant PF landmarks could be identified and metrices were extracted with acceptable inter- and intra-rater variability. Intra-rater variation was marginal, with relative absolute differences ranging from 5 to 21% and 3.2-44%. Inter-rater variability was reported using correlation and Bland-Altman plots. Correlation between raters was satisfactory, with r2 > 0.93, and bias ranged from - 1.8 to 0.65 mm. Moreover, the limit of agreement in the Bland-Altman plot ranged from 5.8 to 20.4 mm, indicating satisfactory precision.

Discussion: The proposed uMRDP technique can be used as a feasible and reliable alternative to supine MRDP, without the necessity of gadolinium injection and bowel preparation. It can capture defaecation in a regular seated posture and can provide information complementary to standard-of-care fluoroscopic proctography for clinicians.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
58
审稿时长
>12 weeks
期刊介绍: MAGMA is a multidisciplinary international journal devoted to the publication of articles on all aspects of magnetic resonance techniques and their applications in medicine and biology. MAGMA currently publishes research papers, reviews, letters to the editor, and commentaries, six times a year. The subject areas covered by MAGMA include: advances in materials, hardware and software in magnetic resonance technology, new developments and results in research and practical applications of magnetic resonance imaging and spectroscopy related to biology and medicine, study of animal models and intact cells using magnetic resonance, reports of clinical trials on humans and clinical validation of magnetic resonance protocols.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信