Mitsuhiko Shoda, Kimitake Imamura, Mitsuru Takami, Koji Fukuzawa
{"title":"心铅植入21年后心房铅捕获阈值的心动过缓依赖性短暂上升。","authors":"Mitsuhiko Shoda, Kimitake Imamura, Mitsuru Takami, Koji Fukuzawa","doi":"10.1111/pace.70041","DOIUrl":null,"url":null,"abstract":"<p><p>We present a man with an implantable cardioverter defibrillator implanted for Brugada syndrome. Twenty-one years later, he underwent catheter ablation of atrial fibrillation and tachycardia. Bradycardia-dependent transient loss of atrial capture was observed 3 months post-ablation, undetected by the automatic pacing threshold adjustment algorithm performed at a pacing rate higher than the programmed setting. We report a transient bradycardia-dependent rise in the capture threshold over 20 years post-implantation, along with its mechanism.</p>","PeriodicalId":520740,"journal":{"name":"Pacing and clinical electrophysiology : PACE","volume":" ","pages":"1119-1122"},"PeriodicalIF":1.3000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bradycardia-Dependent Transient Rise in the Atrial Lead Capture Threshold 21 Years After the Lead Implantation.\",\"authors\":\"Mitsuhiko Shoda, Kimitake Imamura, Mitsuru Takami, Koji Fukuzawa\",\"doi\":\"10.1111/pace.70041\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present a man with an implantable cardioverter defibrillator implanted for Brugada syndrome. Twenty-one years later, he underwent catheter ablation of atrial fibrillation and tachycardia. Bradycardia-dependent transient loss of atrial capture was observed 3 months post-ablation, undetected by the automatic pacing threshold adjustment algorithm performed at a pacing rate higher than the programmed setting. We report a transient bradycardia-dependent rise in the capture threshold over 20 years post-implantation, along with its mechanism.</p>\",\"PeriodicalId\":520740,\"journal\":{\"name\":\"Pacing and clinical electrophysiology : PACE\",\"volume\":\" \",\"pages\":\"1119-1122\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pacing and clinical electrophysiology : PACE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.70041\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/9/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pacing and clinical electrophysiology : PACE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/pace.70041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Bradycardia-Dependent Transient Rise in the Atrial Lead Capture Threshold 21 Years After the Lead Implantation.
We present a man with an implantable cardioverter defibrillator implanted for Brugada syndrome. Twenty-one years later, he underwent catheter ablation of atrial fibrillation and tachycardia. Bradycardia-dependent transient loss of atrial capture was observed 3 months post-ablation, undetected by the automatic pacing threshold adjustment algorithm performed at a pacing rate higher than the programmed setting. We report a transient bradycardia-dependent rise in the capture threshold over 20 years post-implantation, along with its mechanism.