{"title":"EVOQUE Eos系统用于经导管二尖瓣置换术的设备概况:简要回顾。","authors":"Michail Penteris, Konstantinos Lampropoulos","doi":"10.1080/17434440.2025.2561242","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Severe mitral regurgitation (MR) poses significant therapeutic challenges, especially in patients at high surgical risk or unsuitable for transcatheter edge-to-edge repair (TEER). Transcatheter mitral valve replacement (TMVR) has emerged as a viable alternative, with the EVOQUE Eos system representing a next-generation, fully retrievable, transseptal TMVR platform tailored to address prior limitations in safety, anatomical fit, and procedural control.</p><p><strong>Areas covered: </strong>This review outlines the design features, procedural considerations, and early clinical performance of the EVOQUE Eos TMVR system, referencing results from the first-in-human experience and the ongoing MISCEND trial. Furthermore, the EVOQUE Eos is compared with other contemporary TMVR systems. Procedural challenges such as paravalvular leak, left ventricular outflow tract (LVOT) obstruction, bleeding, and hypoattenuated leaflet thickening (HALT) are discussed in context.</p><p><strong>Expert opinion: </strong>The EVOQUE Eos system marks a pivotal advancement in TMVR by offering fully percutaneous access, intuitive deployment, and retrievability. While early outcomes are encouraging, further data are needed to guide patient selection, antithrombotic management, and long-term valve durability. The system may play a central role in the expanding treatment landscape for MR, potentially transforming standard practice in the coming years.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":" ","pages":"1-7"},"PeriodicalIF":2.7000,"publicationDate":"2025-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Device profile of the EVOQUE Eos system for transcatheter mitral valve replacement: a brief narrative review.\",\"authors\":\"Michail Penteris, Konstantinos Lampropoulos\",\"doi\":\"10.1080/17434440.2025.2561242\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Severe mitral regurgitation (MR) poses significant therapeutic challenges, especially in patients at high surgical risk or unsuitable for transcatheter edge-to-edge repair (TEER). Transcatheter mitral valve replacement (TMVR) has emerged as a viable alternative, with the EVOQUE Eos system representing a next-generation, fully retrievable, transseptal TMVR platform tailored to address prior limitations in safety, anatomical fit, and procedural control.</p><p><strong>Areas covered: </strong>This review outlines the design features, procedural considerations, and early clinical performance of the EVOQUE Eos TMVR system, referencing results from the first-in-human experience and the ongoing MISCEND trial. Furthermore, the EVOQUE Eos is compared with other contemporary TMVR systems. Procedural challenges such as paravalvular leak, left ventricular outflow tract (LVOT) obstruction, bleeding, and hypoattenuated leaflet thickening (HALT) are discussed in context.</p><p><strong>Expert opinion: </strong>The EVOQUE Eos system marks a pivotal advancement in TMVR by offering fully percutaneous access, intuitive deployment, and retrievability. While early outcomes are encouraging, further data are needed to guide patient selection, antithrombotic management, and long-term valve durability. The system may play a central role in the expanding treatment landscape for MR, potentially transforming standard practice in the coming years.</p>\",\"PeriodicalId\":94006,\"journal\":{\"name\":\"Expert review of medical devices\",\"volume\":\" \",\"pages\":\"1-7\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2025-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert review of medical devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2025.2561242\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2025.2561242","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
严重的二尖瓣返流(MR)带来了重大的治疗挑战,特别是在手术风险高或不适合经导管边缘到边缘修复(TEER)的患者中。经导管二尖瓣置换术(TMVR)已经成为一种可行的替代方案,EVOQUE Eos系统代表了下一代、完全可回收的经隔膜TMVR平台,旨在解决先前在安全性、解剖配合和程序控制方面的局限性。涵盖领域:本综述概述了EVOQUE Eos TMVR系统的设计特点、程序考虑和早期临床表现,参考了首次人体试验和正在进行的MISCEND试验的结果。此外,EVOQUE Eos与其他当代TMVR系统进行了比较。程序上的挑战,如瓣旁漏,左心室流出道(LVOT)阻塞,出血,小叶减薄增厚(HALT)在上下文中进行了讨论。专家意见:EVOQUE Eos系统通过提供完全经皮通路、直观部署和可回收性,标志着TMVR的关键进步。虽然早期结果令人鼓舞,但需要进一步的数据来指导患者选择,抗血栓管理和长期瓣膜耐久性。该系统可能在扩大核磁共振治疗领域发挥核心作用,有可能在未来几年改变标准做法。
Device profile of the EVOQUE Eos system for transcatheter mitral valve replacement: a brief narrative review.
Introduction: Severe mitral regurgitation (MR) poses significant therapeutic challenges, especially in patients at high surgical risk or unsuitable for transcatheter edge-to-edge repair (TEER). Transcatheter mitral valve replacement (TMVR) has emerged as a viable alternative, with the EVOQUE Eos system representing a next-generation, fully retrievable, transseptal TMVR platform tailored to address prior limitations in safety, anatomical fit, and procedural control.
Areas covered: This review outlines the design features, procedural considerations, and early clinical performance of the EVOQUE Eos TMVR system, referencing results from the first-in-human experience and the ongoing MISCEND trial. Furthermore, the EVOQUE Eos is compared with other contemporary TMVR systems. Procedural challenges such as paravalvular leak, left ventricular outflow tract (LVOT) obstruction, bleeding, and hypoattenuated leaflet thickening (HALT) are discussed in context.
Expert opinion: The EVOQUE Eos system marks a pivotal advancement in TMVR by offering fully percutaneous access, intuitive deployment, and retrievability. While early outcomes are encouraging, further data are needed to guide patient selection, antithrombotic management, and long-term valve durability. The system may play a central role in the expanding treatment landscape for MR, potentially transforming standard practice in the coming years.