Martina Cacciapuoti, Lucia Federica Stefanelli, Elena Sgrò, Dorella Del Prete, Ugo Vertolli, Lorenzo Calò, Federico Nalesso
{"title":"肾盂肾炎及其并发症最合适的影像学分析:临床证据。","authors":"Martina Cacciapuoti, Lucia Federica Stefanelli, Elena Sgrò, Dorella Del Prete, Ugo Vertolli, Lorenzo Calò, Federico Nalesso","doi":"10.69097/42-04-2025-09","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background.</b> Although renal ultrasound or computed tomography (CT) without contrast may allow the diagnosis of complicated acute pyelonephritis (PN), they may fail to diagnose renal abscesses and complicated PN, which is allowed by the upper level imaging: contrast CT or Nuclear Magnetic Resonance (MRI). <b>Case presentation.</b> We report three clinical cases of patients admitted to the Nephrology, Dialysis and Transplantation Unit at Padua University Hospital in which renal ultrasound (US) and Computed Tomography (CT) without contrast failed to allow diagnosis of PN complications, while contrast CT showed renal abscesses in two patients and Nuclear Magnetic Resonance (NMR) without contrast a frank PN in one. <b>Conclusion.</b> Contrast CT or MRI should be preferred to renal US and/or CT without contrast and are the most indicated imaging analyses to be prescribed in acute complicated PN, in particular in the presence of acute kidney injury.</p>","PeriodicalId":12553,"journal":{"name":"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia","volume":"42 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Most Appropriate Imaging Analysis in Pyelonephritis and Its Complications: Clinical Evidence.\",\"authors\":\"Martina Cacciapuoti, Lucia Federica Stefanelli, Elena Sgrò, Dorella Del Prete, Ugo Vertolli, Lorenzo Calò, Federico Nalesso\",\"doi\":\"10.69097/42-04-2025-09\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background.</b> Although renal ultrasound or computed tomography (CT) without contrast may allow the diagnosis of complicated acute pyelonephritis (PN), they may fail to diagnose renal abscesses and complicated PN, which is allowed by the upper level imaging: contrast CT or Nuclear Magnetic Resonance (MRI). <b>Case presentation.</b> We report three clinical cases of patients admitted to the Nephrology, Dialysis and Transplantation Unit at Padua University Hospital in which renal ultrasound (US) and Computed Tomography (CT) without contrast failed to allow diagnosis of PN complications, while contrast CT showed renal abscesses in two patients and Nuclear Magnetic Resonance (NMR) without contrast a frank PN in one. <b>Conclusion.</b> Contrast CT or MRI should be preferred to renal US and/or CT without contrast and are the most indicated imaging analyses to be prescribed in acute complicated PN, in particular in the presence of acute kidney injury.</p>\",\"PeriodicalId\":12553,\"journal\":{\"name\":\"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia\",\"volume\":\"42 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.69097/42-04-2025-09\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.69097/42-04-2025-09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
The Most Appropriate Imaging Analysis in Pyelonephritis and Its Complications: Clinical Evidence.
Background. Although renal ultrasound or computed tomography (CT) without contrast may allow the diagnosis of complicated acute pyelonephritis (PN), they may fail to diagnose renal abscesses and complicated PN, which is allowed by the upper level imaging: contrast CT or Nuclear Magnetic Resonance (MRI). Case presentation. We report three clinical cases of patients admitted to the Nephrology, Dialysis and Transplantation Unit at Padua University Hospital in which renal ultrasound (US) and Computed Tomography (CT) without contrast failed to allow diagnosis of PN complications, while contrast CT showed renal abscesses in two patients and Nuclear Magnetic Resonance (NMR) without contrast a frank PN in one. Conclusion. Contrast CT or MRI should be preferred to renal US and/or CT without contrast and are the most indicated imaging analyses to be prescribed in acute complicated PN, in particular in the presence of acute kidney injury.
期刊介绍:
Il Giornale Italiano di Nefrologia (GIN) è la rivista di educazione continua della Società Italiana di Nefrologia SIN ed è pubblicato bimestralmente. E" il più autorevole organo di informazione nefrologia disponibile a livello nazionale. Il giornale Italiano di Nefrologia offre la più aggiornata informazione medico-scientifica rivolta al nefrologo sotto forma di rassegne, casi clinici e articoli finalizzati all’Educazione Continua in Medicina, oltre ai notiziari ed agli atti dei congressi di questa prestigiosa Società Scientifica