{"title":"【3d打印导航在男性下尿路症状患者生殖器神经调节中的应用】。","authors":"Zi-Qin Zhou, Xin Song, Yin-Jun Gu, Jian-Wei Lü","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the efficacy of 3D-printed navigation guided pudendal lead implantation on nervous regulation of lower urinary tract symptoms(LUTS) in male patients.</p><p><strong>Methods: </strong>Twenty-eight male patients who underwent perineal nervous regulation treatment for LUTS in Gongli Hospital of Pudong New Area from October 2021 to October 2023 were randomly divided into observation group and control group. The technology assisted with 3D-printed navigation to regulate the genital nerves was used in observation group. And the patients in control group were treated with regulation of the genital nerves by routine puncture. Operation time of puncture, number of surgical punctures, and stimulator debugging time compared between the two groups. The improvement of postoperative symptoms and surgical complications of patients in the observation group were recorded as well.</p><p><strong>Result: </strong>A total of 12 male LUTS patients were included in the observation group, with an average age of 36.5±6.5 years, including 7 cases of frequent micturition, 3 cases of perineal pain, and 2 cases of dysuria. Four patients showed no significant improvement in symptoms, including two patients with pain and two cases of frequent micturition who did not undergo secondary surgery. While the other eight patients showed significant improvement in symptoms. The average time for successful puncture in control group was (21.13 ± 4.53) minutes, which was longer than that of the 3D-printed navigation group ([10.32 ± 3.42] min) significantly (P<0.05). The average number of punctures in the ordinary puncture group was 5.62 ± 1.43, which was significantly higher than that in the 3D-printed navigation group (1.5 ± 0.56). There was no statistically significant difference in the average time for stimulator debugging between the two groups of patients. The conversion rate of the 3D-printed navigation group in the second phase was 66.7%, which was higher than that (37.5%) significantly (P<0.05).</p><p><strong>Conclusion: </strong>3D printing navigation of pudendal nerve electrode wire implantation can improve the accuracy of electrode implantation and the conversion rate to a certain extent, which has the advantages of reducing the difficulty of surgery.</p>","PeriodicalId":24012,"journal":{"name":"中华男科学杂志","volume":"31 8","pages":"698-702"},"PeriodicalIF":0.0000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Application of 3D-printed navigation for genital nerve regulation in male with lower urinary tract symptoms].\",\"authors\":\"Zi-Qin Zhou, Xin Song, Yin-Jun Gu, Jian-Wei Lü\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate the efficacy of 3D-printed navigation guided pudendal lead implantation on nervous regulation of lower urinary tract symptoms(LUTS) in male patients.</p><p><strong>Methods: </strong>Twenty-eight male patients who underwent perineal nervous regulation treatment for LUTS in Gongli Hospital of Pudong New Area from October 2021 to October 2023 were randomly divided into observation group and control group. The technology assisted with 3D-printed navigation to regulate the genital nerves was used in observation group. And the patients in control group were treated with regulation of the genital nerves by routine puncture. Operation time of puncture, number of surgical punctures, and stimulator debugging time compared between the two groups. The improvement of postoperative symptoms and surgical complications of patients in the observation group were recorded as well.</p><p><strong>Result: </strong>A total of 12 male LUTS patients were included in the observation group, with an average age of 36.5±6.5 years, including 7 cases of frequent micturition, 3 cases of perineal pain, and 2 cases of dysuria. Four patients showed no significant improvement in symptoms, including two patients with pain and two cases of frequent micturition who did not undergo secondary surgery. While the other eight patients showed significant improvement in symptoms. The average time for successful puncture in control group was (21.13 ± 4.53) minutes, which was longer than that of the 3D-printed navigation group ([10.32 ± 3.42] min) significantly (P<0.05). The average number of punctures in the ordinary puncture group was 5.62 ± 1.43, which was significantly higher than that in the 3D-printed navigation group (1.5 ± 0.56). There was no statistically significant difference in the average time for stimulator debugging between the two groups of patients. The conversion rate of the 3D-printed navigation group in the second phase was 66.7%, which was higher than that (37.5%) significantly (P<0.05).</p><p><strong>Conclusion: </strong>3D printing navigation of pudendal nerve electrode wire implantation can improve the accuracy of electrode implantation and the conversion rate to a certain extent, which has the advantages of reducing the difficulty of surgery.</p>\",\"PeriodicalId\":24012,\"journal\":{\"name\":\"中华男科学杂志\",\"volume\":\"31 8\",\"pages\":\"698-702\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华男科学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华男科学杂志","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
[Application of 3D-printed navigation for genital nerve regulation in male with lower urinary tract symptoms].
Objective: To investigate the efficacy of 3D-printed navigation guided pudendal lead implantation on nervous regulation of lower urinary tract symptoms(LUTS) in male patients.
Methods: Twenty-eight male patients who underwent perineal nervous regulation treatment for LUTS in Gongli Hospital of Pudong New Area from October 2021 to October 2023 were randomly divided into observation group and control group. The technology assisted with 3D-printed navigation to regulate the genital nerves was used in observation group. And the patients in control group were treated with regulation of the genital nerves by routine puncture. Operation time of puncture, number of surgical punctures, and stimulator debugging time compared between the two groups. The improvement of postoperative symptoms and surgical complications of patients in the observation group were recorded as well.
Result: A total of 12 male LUTS patients were included in the observation group, with an average age of 36.5±6.5 years, including 7 cases of frequent micturition, 3 cases of perineal pain, and 2 cases of dysuria. Four patients showed no significant improvement in symptoms, including two patients with pain and two cases of frequent micturition who did not undergo secondary surgery. While the other eight patients showed significant improvement in symptoms. The average time for successful puncture in control group was (21.13 ± 4.53) minutes, which was longer than that of the 3D-printed navigation group ([10.32 ± 3.42] min) significantly (P<0.05). The average number of punctures in the ordinary puncture group was 5.62 ± 1.43, which was significantly higher than that in the 3D-printed navigation group (1.5 ± 0.56). There was no statistically significant difference in the average time for stimulator debugging between the two groups of patients. The conversion rate of the 3D-printed navigation group in the second phase was 66.7%, which was higher than that (37.5%) significantly (P<0.05).
Conclusion: 3D printing navigation of pudendal nerve electrode wire implantation can improve the accuracy of electrode implantation and the conversion rate to a certain extent, which has the advantages of reducing the difficulty of surgery.
期刊介绍:
National journal of andrology was founded in June 1995. It is a core journal of andrology and reproductive medicine, published monthly, and is publicly distributed at home and abroad. The main columns include expert talks, monographs (basic research, clinical research, evidence-based medicine, traditional Chinese medicine), reviews, clinical experience exchanges, case reports, etc. Priority is given to various fund-funded projects, especially the 12th Five-Year National Support Plan and the National Natural Science Foundation funded projects. This journal is included in about 20 domestic databases, including the National Science and Technology Paper Statistical Source Journal (China Science and Technology Core Journal), the Source Journal of the China Science Citation Database, the Statistical Source Journal of the China Academic Journal Comprehensive Evaluation Database (CAJCED), the Full-text Collection Journal of the China Journal Full-text Database (CJFD), the Overview of the Chinese Core Journals (2017 Edition), and the Source Journal of the Top Academic Papers of China's Fine Science and Technology Journals (F5000). It has been included in the full text of the American Chemical Abstracts, the American MEDLINE, the American EBSCO, and the database.