非cfu生物荧光粒子计数技术验证的考虑。

Q3 Medicine
Cynthia Martindale, Caroline Dreyer, Cedric Joossen, Joanny Salvas, Kim Perkins, Mike Dingle, Petra Merker, Philip Villari, Tony Cundell, Margit Franz-Riethdorf, Patrick Hutchins
{"title":"非cfu生物荧光粒子计数技术验证的考虑。","authors":"Cynthia Martindale, Caroline Dreyer, Cedric Joossen, Joanny Salvas, Kim Perkins, Mike Dingle, Petra Merker, Philip Villari, Tony Cundell, Margit Franz-Riethdorf, Patrick Hutchins","doi":"10.5731/pdajpst.2024-003036.1","DOIUrl":null,"url":null,"abstract":"<p><p>The use of Bio-Fluorescent Particle Counting technologies as a rapid, alternative method to monitor microbial contamination in water and cleanroom air samples has been of interest to the pharmaceutical industry for several years. These technologies are a non-growth-based method that use the detection of particle scatter and intrinsic fluorescence to categorize detected particles as biologic or non-biologic. As a result, the systems report in a unit of measure not equivalent to the colony forming unit. Although guidance on the validation of alternative microbial methods is available, significant challenges can exist when validating non-growth based alternative methods compared to the growth-based compendial method. Collaborators in the Modern Microbial Methods (M<sup>3</sup>) industry working group provide thoughts and recommendations on a method validation pathway for the non-growth-based bio-fluorescent particle counting technology. Technology specific recommendations on the primary and secondary validation are provided with considerations on the applicability of individual validation parameters and associated acceptance criteria for this emerging technology that does not rely on the colony-forming unit.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Considerations for the Validation of Non-CFU Based Bio-Fluorescent Particle Counting Technologies.\",\"authors\":\"Cynthia Martindale, Caroline Dreyer, Cedric Joossen, Joanny Salvas, Kim Perkins, Mike Dingle, Petra Merker, Philip Villari, Tony Cundell, Margit Franz-Riethdorf, Patrick Hutchins\",\"doi\":\"10.5731/pdajpst.2024-003036.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of Bio-Fluorescent Particle Counting technologies as a rapid, alternative method to monitor microbial contamination in water and cleanroom air samples has been of interest to the pharmaceutical industry for several years. These technologies are a non-growth-based method that use the detection of particle scatter and intrinsic fluorescence to categorize detected particles as biologic or non-biologic. As a result, the systems report in a unit of measure not equivalent to the colony forming unit. Although guidance on the validation of alternative microbial methods is available, significant challenges can exist when validating non-growth based alternative methods compared to the growth-based compendial method. Collaborators in the Modern Microbial Methods (M<sup>3</sup>) industry working group provide thoughts and recommendations on a method validation pathway for the non-growth-based bio-fluorescent particle counting technology. Technology specific recommendations on the primary and secondary validation are provided with considerations on the applicability of individual validation parameters and associated acceptance criteria for this emerging technology that does not rely on the colony-forming unit.</p>\",\"PeriodicalId\":19986,\"journal\":{\"name\":\"PDA Journal of Pharmaceutical Science and Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-09-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PDA Journal of Pharmaceutical Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5731/pdajpst.2024-003036.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2024-003036.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

生物荧光粒子计数技术作为一种快速、可替代的方法来监测水和洁净室空气样品中的微生物污染,多年来一直是制药行业的兴趣。这些技术是一种非生长为基础的方法,利用检测粒子散射和固有荧光来将检测到的粒子分类为生物或非生物。因此,系统报告的度量单位不等同于群体形成单位。尽管已有关于微生物替代方法验证的指南,但与基于生长的药典方法相比,在验证非基于生长的替代方法时可能存在重大挑战。现代微生物方法(M3)行业工作组的合作者就非生长基础生物荧光颗粒计数技术的方法验证途径提供了想法和建议。关于主要和次要验证的技术具体建议提供了对单个验证参数的适用性的考虑,以及不依赖于菌落形成单元的新兴技术的相关接受标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Considerations for the Validation of Non-CFU Based Bio-Fluorescent Particle Counting Technologies.

The use of Bio-Fluorescent Particle Counting technologies as a rapid, alternative method to monitor microbial contamination in water and cleanroom air samples has been of interest to the pharmaceutical industry for several years. These technologies are a non-growth-based method that use the detection of particle scatter and intrinsic fluorescence to categorize detected particles as biologic or non-biologic. As a result, the systems report in a unit of measure not equivalent to the colony forming unit. Although guidance on the validation of alternative microbial methods is available, significant challenges can exist when validating non-growth based alternative methods compared to the growth-based compendial method. Collaborators in the Modern Microbial Methods (M3) industry working group provide thoughts and recommendations on a method validation pathway for the non-growth-based bio-fluorescent particle counting technology. Technology specific recommendations on the primary and secondary validation are provided with considerations on the applicability of individual validation parameters and associated acceptance criteria for this emerging technology that does not rely on the colony-forming unit.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信