{"title":"全血全自动高灵敏度心肌肌钙蛋白I测定的分析和临床评价。","authors":"Jin-Xing Yu, Kai Cui, Yang Li, Fang-Fang Yang, Fen Xu, Zhou Zhou, Ya-Hui Lin","doi":"10.1515/cclm-2025-0143","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the performance of the iStar high-sensitivity cardiac troponin I (hs-cTnI) assay, focusing on its sensitivity, precision, linearity, and consistency with plasma samples, and to establish sex-specific 99th percentile upper reference limits.</p><p><strong>Methods: </strong>The iStar hs-cTnI assay was assessed using the Drawray iStar 500 analyzer. Key performance metrics such as the limits of blank (LoB), detection (LoD) and quantitation (LoQ), precision, linearity, and agreement between sample types were evaluated according to Clinical and Laboratory Standards Institute (CLSI) guidelines. A methodological comparison was performed with the Abbott ARCHITECT hs-cTnI assay, and cross-reactivity with others troponins was assessed.</p><p><strong>Results: </strong>The iStar hs-cTnI assay demonstrated robust sensitivity with a LoB of 0.09 ng/L and LoD of 0.31 ng/L. The LoQ was 0.79 ng/L for 20 % coefficient of variation (CV) and 1.85 ng/L for 10 % CV. Precision testing revealed CVs of 1.4-4.8 % near the 99th percentile upper reference limit (URL). The assay exhibited excellent linearity (r=1.00) and high agreement between whole blood and plasma samples (slope=0.936). Methodological comparison with the Abbott ARCHITECT hs-cTnI showed a high correlation coefficient of 0.983. Cross-reactivity with skeletal muscle troponin I, cardiac troponin C, and cardiac troponin T was negligible. In healthy individuals, the overall 99th percentile URL was 16 ng/L, with sex-specific values of 18 ng/L for males and 14 ng/L for females.</p><p><strong>Conclusions: </strong>The iStar hs-cTnI assay demonstrates high sensitivity and precision, supporting it suitable for the rapid diagnosis of acute myocardial infarction using whole blood samples. Its high agreement with plasma and established sex-specific URL support its potential for clinical use in acute coronary syndrome management.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analytical and clinical evaluation of an automated high-sensitivity cardiac troponin I assay for whole blood.\",\"authors\":\"Jin-Xing Yu, Kai Cui, Yang Li, Fang-Fang Yang, Fen Xu, Zhou Zhou, Ya-Hui Lin\",\"doi\":\"10.1515/cclm-2025-0143\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate the performance of the iStar high-sensitivity cardiac troponin I (hs-cTnI) assay, focusing on its sensitivity, precision, linearity, and consistency with plasma samples, and to establish sex-specific 99th percentile upper reference limits.</p><p><strong>Methods: </strong>The iStar hs-cTnI assay was assessed using the Drawray iStar 500 analyzer. Key performance metrics such as the limits of blank (LoB), detection (LoD) and quantitation (LoQ), precision, linearity, and agreement between sample types were evaluated according to Clinical and Laboratory Standards Institute (CLSI) guidelines. A methodological comparison was performed with the Abbott ARCHITECT hs-cTnI assay, and cross-reactivity with others troponins was assessed.</p><p><strong>Results: </strong>The iStar hs-cTnI assay demonstrated robust sensitivity with a LoB of 0.09 ng/L and LoD of 0.31 ng/L. The LoQ was 0.79 ng/L for 20 % coefficient of variation (CV) and 1.85 ng/L for 10 % CV. Precision testing revealed CVs of 1.4-4.8 % near the 99th percentile upper reference limit (URL). The assay exhibited excellent linearity (r=1.00) and high agreement between whole blood and plasma samples (slope=0.936). Methodological comparison with the Abbott ARCHITECT hs-cTnI showed a high correlation coefficient of 0.983. Cross-reactivity with skeletal muscle troponin I, cardiac troponin C, and cardiac troponin T was negligible. In healthy individuals, the overall 99th percentile URL was 16 ng/L, with sex-specific values of 18 ng/L for males and 14 ng/L for females.</p><p><strong>Conclusions: </strong>The iStar hs-cTnI assay demonstrates high sensitivity and precision, supporting it suitable for the rapid diagnosis of acute myocardial infarction using whole blood samples. Its high agreement with plasma and established sex-specific URL support its potential for clinical use in acute coronary syndrome management.</p>\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2025-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2025-0143\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2025-0143","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Analytical and clinical evaluation of an automated high-sensitivity cardiac troponin I assay for whole blood.
Objectives: To evaluate the performance of the iStar high-sensitivity cardiac troponin I (hs-cTnI) assay, focusing on its sensitivity, precision, linearity, and consistency with plasma samples, and to establish sex-specific 99th percentile upper reference limits.
Methods: The iStar hs-cTnI assay was assessed using the Drawray iStar 500 analyzer. Key performance metrics such as the limits of blank (LoB), detection (LoD) and quantitation (LoQ), precision, linearity, and agreement between sample types were evaluated according to Clinical and Laboratory Standards Institute (CLSI) guidelines. A methodological comparison was performed with the Abbott ARCHITECT hs-cTnI assay, and cross-reactivity with others troponins was assessed.
Results: The iStar hs-cTnI assay demonstrated robust sensitivity with a LoB of 0.09 ng/L and LoD of 0.31 ng/L. The LoQ was 0.79 ng/L for 20 % coefficient of variation (CV) and 1.85 ng/L for 10 % CV. Precision testing revealed CVs of 1.4-4.8 % near the 99th percentile upper reference limit (URL). The assay exhibited excellent linearity (r=1.00) and high agreement between whole blood and plasma samples (slope=0.936). Methodological comparison with the Abbott ARCHITECT hs-cTnI showed a high correlation coefficient of 0.983. Cross-reactivity with skeletal muscle troponin I, cardiac troponin C, and cardiac troponin T was negligible. In healthy individuals, the overall 99th percentile URL was 16 ng/L, with sex-specific values of 18 ng/L for males and 14 ng/L for females.
Conclusions: The iStar hs-cTnI assay demonstrates high sensitivity and precision, supporting it suitable for the rapid diagnosis of acute myocardial infarction using whole blood samples. Its high agreement with plasma and established sex-specific URL support its potential for clinical use in acute coronary syndrome management.
期刊介绍:
Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically.
CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France).
Topics:
- clinical biochemistry
- clinical genomics and molecular biology
- clinical haematology and coagulation
- clinical immunology and autoimmunity
- clinical microbiology
- drug monitoring and analysis
- evaluation of diagnostic biomarkers
- disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes)
- new reagents, instrumentation and technologies
- new methodologies
- reference materials and methods
- reference values and decision limits
- quality and safety in laboratory medicine
- translational laboratory medicine
- clinical metrology
Follow @cclm_degruyter on Twitter!