现代植入式心律转复除颤器和心脏再同步治疗除颤器的电池寿命

IF 1.7 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Kotaro Nishino, Taro Temma, Masaya Watanabe, Motoki Nakao, Masahiro Kawasaki, Kintaro Shimano, Kei Kawakami, Shota Saito, Jiro Koya, Daishiro Tatsuta, Hiroyuki Natsui, Takuya Koizumi, Takahide Kadosaka, Taro Koya, Kiwamu Kamiya, Toshiyuki Nagai, Toshihisa Anzai
{"title":"现代植入式心律转复除颤器和心脏再同步治疗除颤器的电池寿命","authors":"Kotaro Nishino,&nbsp;Taro Temma,&nbsp;Masaya Watanabe,&nbsp;Motoki Nakao,&nbsp;Masahiro Kawasaki,&nbsp;Kintaro Shimano,&nbsp;Kei Kawakami,&nbsp;Shota Saito,&nbsp;Jiro Koya,&nbsp;Daishiro Tatsuta,&nbsp;Hiroyuki Natsui,&nbsp;Takuya Koizumi,&nbsp;Takahide Kadosaka,&nbsp;Taro Koya,&nbsp;Kiwamu Kamiya,&nbsp;Toshiyuki Nagai,&nbsp;Toshihisa Anzai","doi":"10.1002/joa3.70175","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Battery longevity in high-voltage devices (HVDs), specifically implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy-defibrillators (CRT-Ds), is critical for reducing the frequency of generator replacements, minimizing procedural risks, and enhancing patient outcomes. Despite technological advancements, significant variability in battery performance remains among the major manufacturers. This study aimed to evaluate the battery longevity among ICDs and CRT-Ds from the major manufacturers implanted at a single institution and identify the factors influencing battery depletion.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We conducted a retrospective analysis of 353 patients implanted with HVDs (63 Abbott, 150 Boston Scientific, 140 Medtronic) at Hokkaido University Hospital between 2012 and 2021. Kaplan–Meier curves and Cox proportional hazards models were used to analyze the device longevity, with a primary endpoint of the time to battery depletion, defined by the elective replacement indicator. A multivariate analysis adjusted for the potential confounders.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Boston Scientific devices exhibited a significantly longer battery life than Abbott and Medtronic devices (<i>p</i> &lt; 0.001), with a 6-year replacement-free survival of 99% for ICDs and 93% for CRT-Ds. A multivariate analysis identified the device manufacturer, device type (ICD vs. CRT-D), and ventricular pacing rate as independent predictors of battery depletion (<i>p</i> &lt; 0.001).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Battery longevity differed significantly by the manufacturer, which may influence device selection. Devices with a longer battery life may help reduce the replacement frequency and could potentially contribute to improved patient outcomes and cost-effectiveness.</p>\n </section>\n </div>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"41 4","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70175","citationCount":"0","resultStr":"{\"title\":\"Battery Longevity in Modern Implantable Cardioverter-Defibrillators and Cardiac Resynchronization Therapy-Defibrillators\",\"authors\":\"Kotaro Nishino,&nbsp;Taro Temma,&nbsp;Masaya Watanabe,&nbsp;Motoki Nakao,&nbsp;Masahiro Kawasaki,&nbsp;Kintaro Shimano,&nbsp;Kei Kawakami,&nbsp;Shota Saito,&nbsp;Jiro Koya,&nbsp;Daishiro Tatsuta,&nbsp;Hiroyuki Natsui,&nbsp;Takuya Koizumi,&nbsp;Takahide Kadosaka,&nbsp;Taro Koya,&nbsp;Kiwamu Kamiya,&nbsp;Toshiyuki Nagai,&nbsp;Toshihisa Anzai\",\"doi\":\"10.1002/joa3.70175\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Battery longevity in high-voltage devices (HVDs), specifically implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy-defibrillators (CRT-Ds), is critical for reducing the frequency of generator replacements, minimizing procedural risks, and enhancing patient outcomes. Despite technological advancements, significant variability in battery performance remains among the major manufacturers. This study aimed to evaluate the battery longevity among ICDs and CRT-Ds from the major manufacturers implanted at a single institution and identify the factors influencing battery depletion.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We conducted a retrospective analysis of 353 patients implanted with HVDs (63 Abbott, 150 Boston Scientific, 140 Medtronic) at Hokkaido University Hospital between 2012 and 2021. Kaplan–Meier curves and Cox proportional hazards models were used to analyze the device longevity, with a primary endpoint of the time to battery depletion, defined by the elective replacement indicator. A multivariate analysis adjusted for the potential confounders.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Boston Scientific devices exhibited a significantly longer battery life than Abbott and Medtronic devices (<i>p</i> &lt; 0.001), with a 6-year replacement-free survival of 99% for ICDs and 93% for CRT-Ds. A multivariate analysis identified the device manufacturer, device type (ICD vs. CRT-D), and ventricular pacing rate as independent predictors of battery depletion (<i>p</i> &lt; 0.001).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Battery longevity differed significantly by the manufacturer, which may influence device selection. Devices with a longer battery life may help reduce the replacement frequency and could potentially contribute to improved patient outcomes and cost-effectiveness.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15174,\"journal\":{\"name\":\"Journal of Arrhythmia\",\"volume\":\"41 4\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70175\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70175\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70175","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

高压设备(hvd),特别是植入式心律转复除颤器(ICDs)和心脏再同步治疗除颤器(CRT-Ds)的电池寿命对于降低发电机更换频率、最小化手术风险和提高患者预后至关重要。尽管技术进步,但主要制造商的电池性能仍然存在显著差异。本研究旨在评估在单一机构植入的主要制造商的icd和crt - d的电池寿命,并确定影响电池耗尽的因素。方法回顾性分析北海道大学医院2012年至2021年间353例植入hvd的患者(63例雅培,150例波士顿科学,140例美敦力)。Kaplan-Meier曲线和Cox比例风险模型用于分析设备寿命,主要终点为电池耗尽时间,由可选更换指标定义。对潜在混杂因素进行多变量分析。结果:Boston Scientific设备的电池寿命明显长于雅培和美敦力设备(p < 0.001), icd的6年无更换生存率为99%,crt - d为93%。一项多变量分析确定了设备制造商、设备类型(ICD vs. CRT-D)和心室起搏率是电池耗尽的独立预测因素(p < 0.001)。结论不同厂家的电池寿命差异较大,可能影响设备的选择。电池寿命较长的设备可能有助于减少更换频率,并可能有助于改善患者的治疗效果和成本效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Battery Longevity in Modern Implantable Cardioverter-Defibrillators and Cardiac Resynchronization Therapy-Defibrillators

Battery Longevity in Modern Implantable Cardioverter-Defibrillators and Cardiac Resynchronization Therapy-Defibrillators

Background

Battery longevity in high-voltage devices (HVDs), specifically implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy-defibrillators (CRT-Ds), is critical for reducing the frequency of generator replacements, minimizing procedural risks, and enhancing patient outcomes. Despite technological advancements, significant variability in battery performance remains among the major manufacturers. This study aimed to evaluate the battery longevity among ICDs and CRT-Ds from the major manufacturers implanted at a single institution and identify the factors influencing battery depletion.

Methods

We conducted a retrospective analysis of 353 patients implanted with HVDs (63 Abbott, 150 Boston Scientific, 140 Medtronic) at Hokkaido University Hospital between 2012 and 2021. Kaplan–Meier curves and Cox proportional hazards models were used to analyze the device longevity, with a primary endpoint of the time to battery depletion, defined by the elective replacement indicator. A multivariate analysis adjusted for the potential confounders.

Results

Boston Scientific devices exhibited a significantly longer battery life than Abbott and Medtronic devices (p < 0.001), with a 6-year replacement-free survival of 99% for ICDs and 93% for CRT-Ds. A multivariate analysis identified the device manufacturer, device type (ICD vs. CRT-D), and ventricular pacing rate as independent predictors of battery depletion (p < 0.001).

Conclusion

Battery longevity differed significantly by the manufacturer, which may influence device selection. Devices with a longer battery life may help reduce the replacement frequency and could potentially contribute to improved patient outcomes and cost-effectiveness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信