物理治疗师在混合女性人群样本中使用实时超声测量直肌间距离的可靠性。

IF 2.9
Women's health (London, England) Pub Date : 2025-01-01 Epub Date: 2025-08-12 DOI:10.1177/17455057251361999
Evdokia Billis, Anastasia Skoura, Tatiana-Elena Papakonstantinou, Dimitra Tania Papanikolaou, Maria Tsekoura, Maria Andriopoulou, Charalampos Matzaroglou, Sofia Lampropoulou, Dimitra Koumoundourou, Eftichia Trachani, Theofani Bania, Elena Drakonaki
{"title":"物理治疗师在混合女性人群样本中使用实时超声测量直肌间距离的可靠性。","authors":"Evdokia Billis, Anastasia Skoura, Tatiana-Elena Papakonstantinou, Dimitra Tania Papanikolaou, Maria Tsekoura, Maria Andriopoulou, Charalampos Matzaroglou, Sofia Lampropoulou, Dimitra Koumoundourou, Eftichia Trachani, Theofani Bania, Elena Drakonaki","doi":"10.1177/17455057251361999","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ultrasound imaging has become popular among physiotherapists for monitoring diastasis rectus abdominis postpartum, but its reliability requires further exploration.</p><p><strong>Objectives: </strong>To investigate physiotherapists' intra-tester, inter-tester, and test-retest reliability of inter-recti distance measurement utilizing real-time ultrasound across a mixed women sample.</p><p><strong>Design: </strong>Reliability study.</p><p><strong>Methods: </strong>Volunteers comprising nulliparous and parous women of different ages and body mass index participated. Five physiotherapists performed ultrasound measurements, following sonographic training. Four conditions were tested in supine; rest, curl-up, transversus abdominus activation, and transversus abdominus with curl-up. Three locations were randomly measured: umbilicus, 3 cm above the umbilicus, and halfway between the umbilicus and xiphoid process. For intra-tester reliability, each therapist undertook three repeated measurements. For inter-tester reliability, mean inter-recti distance measurements were explored across any two tester combinations within and across sessions. Test-retest reliability explored repeated measurements 5-8 days later. Data were analyzed with intraclass correlation coefficients<sub>2,1</sub>.</p><p><strong>Results: </strong>54 women (33.2 ± 15.2 years old, body mass index: 24.2 ± 3.7), 19 (35.2%) being parous participated. Intra-tester reliability across each physiotherapist was very good (intraclass correlation coefficients = 0.677-0.989). Intra-session reliability across any two testers yielded very good results (intraclass correlation coefficients = 0.76-0.92), whereas across-session yielded good reliability (intraclass correlation coefficients >0.76) except for one condition (3 cm above umbilicus in combined transversus abdominus and curl-up). Test-retest reliability was also very good (intraclass correlation coefficients = 0.78-0.96). Significant differences in inter-recti distance were found, with parous women showing consistently larger values (p < 0.05).</p><p><strong>Conclusion: </strong>Physiotherapists, following sonographic training, can reliably measure inter-recti distances in both nulliparous and parous women across active and resting tasks. Thus, ultrasound measurement of inter-recti distance is recommended in physiotherapy practice for monitoring diastasis rectus abdominis and assessing rehabilitation progress. However, sub-umbilical inter-recti distance measurements and the impact of co-contraction on reliability require further research.</p>","PeriodicalId":75327,"journal":{"name":"Women's health (London, England)","volume":"21 ","pages":"17455057251361999"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12344325/pdf/","citationCount":"0","resultStr":"{\"title\":\"Physiotherapists' reliability of inter-recti distance measurement with real-time ultrasound across a mixed women population sample.\",\"authors\":\"Evdokia Billis, Anastasia Skoura, Tatiana-Elena Papakonstantinou, Dimitra Tania Papanikolaou, Maria Tsekoura, Maria Andriopoulou, Charalampos Matzaroglou, Sofia Lampropoulou, Dimitra Koumoundourou, Eftichia Trachani, Theofani Bania, Elena Drakonaki\",\"doi\":\"10.1177/17455057251361999\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Ultrasound imaging has become popular among physiotherapists for monitoring diastasis rectus abdominis postpartum, but its reliability requires further exploration.</p><p><strong>Objectives: </strong>To investigate physiotherapists' intra-tester, inter-tester, and test-retest reliability of inter-recti distance measurement utilizing real-time ultrasound across a mixed women sample.</p><p><strong>Design: </strong>Reliability study.</p><p><strong>Methods: </strong>Volunteers comprising nulliparous and parous women of different ages and body mass index participated. Five physiotherapists performed ultrasound measurements, following sonographic training. Four conditions were tested in supine; rest, curl-up, transversus abdominus activation, and transversus abdominus with curl-up. Three locations were randomly measured: umbilicus, 3 cm above the umbilicus, and halfway between the umbilicus and xiphoid process. For intra-tester reliability, each therapist undertook three repeated measurements. For inter-tester reliability, mean inter-recti distance measurements were explored across any two tester combinations within and across sessions. Test-retest reliability explored repeated measurements 5-8 days later. Data were analyzed with intraclass correlation coefficients<sub>2,1</sub>.</p><p><strong>Results: </strong>54 women (33.2 ± 15.2 years old, body mass index: 24.2 ± 3.7), 19 (35.2%) being parous participated. Intra-tester reliability across each physiotherapist was very good (intraclass correlation coefficients = 0.677-0.989). Intra-session reliability across any two testers yielded very good results (intraclass correlation coefficients = 0.76-0.92), whereas across-session yielded good reliability (intraclass correlation coefficients >0.76) except for one condition (3 cm above umbilicus in combined transversus abdominus and curl-up). Test-retest reliability was also very good (intraclass correlation coefficients = 0.78-0.96). Significant differences in inter-recti distance were found, with parous women showing consistently larger values (p < 0.05).</p><p><strong>Conclusion: </strong>Physiotherapists, following sonographic training, can reliably measure inter-recti distances in both nulliparous and parous women across active and resting tasks. Thus, ultrasound measurement of inter-recti distance is recommended in physiotherapy practice for monitoring diastasis rectus abdominis and assessing rehabilitation progress. However, sub-umbilical inter-recti distance measurements and the impact of co-contraction on reliability require further research.</p>\",\"PeriodicalId\":75327,\"journal\":{\"name\":\"Women's health (London, England)\",\"volume\":\"21 \",\"pages\":\"17455057251361999\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12344325/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Women's health (London, England)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/17455057251361999\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/8/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Women's health (London, England)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17455057251361999","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:超声成像已成为物理治疗师监测产后腹直肌转移的常用方法,但其可靠性有待进一步探讨。目的:探讨物理治疗师使用实时超声测量直肌间距离的测内、测间和重测信度。设计:可靠性研究。方法:不同年龄、不同体重指数的未产妇女和已产妇女自愿参与。五名物理治疗师在超声训练后进行超声测量。在仰卧位上测试四种情况;休息,卷腹,激活腹横肌,腹横肌加卷腹。随机测量三个位置:脐、脐上方3cm、脐与剑突中间。为了测试者内部的可靠性,每个治疗师进行了三次重复测量。对于测试者之间的可靠性,在任何两个测试者组合内和跨会话中探索平均间隔距离测量。测试-重测信度探讨了5-8天后的重复测量。采用类内相关系数2,1进行数据分析。结果:54名妇女(33.2±15.2)岁,体重指数:24.2±3.7),19名产妇(35.2%)参与调查。每位物理治疗师的测试者内部信度非常好(类内相关系数= 0.677-0.989)。任何两个测试者的会话内可靠性都产生了非常好的结果(类内相关系数= 0.76-0.92),而跨会话的可靠性(类内相关系数>0.76)除了一种情况(联合腹侧和卷腹时在脐部以上3厘米)。重测信度也很好(类内相关系数= 0.78 ~ 0.96)。直肠间距离差异有统计学意义(p < 0.05),产妇的直肠间距离持续较大(p < 0.05)。结论:物理治疗师经过超声训练后,可以可靠地测量未分娩和已分娩妇女在活动和休息任务中的直椎间距离。因此,超声测量腹直肌间距离在物理治疗实践中被推荐用于监测腹直肌转移和评估康复进展。然而,脐带下直道距离测量和共收缩对可靠性的影响还需要进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Physiotherapists' reliability of inter-recti distance measurement with real-time ultrasound across a mixed women population sample.

Background: Ultrasound imaging has become popular among physiotherapists for monitoring diastasis rectus abdominis postpartum, but its reliability requires further exploration.

Objectives: To investigate physiotherapists' intra-tester, inter-tester, and test-retest reliability of inter-recti distance measurement utilizing real-time ultrasound across a mixed women sample.

Design: Reliability study.

Methods: Volunteers comprising nulliparous and parous women of different ages and body mass index participated. Five physiotherapists performed ultrasound measurements, following sonographic training. Four conditions were tested in supine; rest, curl-up, transversus abdominus activation, and transversus abdominus with curl-up. Three locations were randomly measured: umbilicus, 3 cm above the umbilicus, and halfway between the umbilicus and xiphoid process. For intra-tester reliability, each therapist undertook three repeated measurements. For inter-tester reliability, mean inter-recti distance measurements were explored across any two tester combinations within and across sessions. Test-retest reliability explored repeated measurements 5-8 days later. Data were analyzed with intraclass correlation coefficients2,1.

Results: 54 women (33.2 ± 15.2 years old, body mass index: 24.2 ± 3.7), 19 (35.2%) being parous participated. Intra-tester reliability across each physiotherapist was very good (intraclass correlation coefficients = 0.677-0.989). Intra-session reliability across any two testers yielded very good results (intraclass correlation coefficients = 0.76-0.92), whereas across-session yielded good reliability (intraclass correlation coefficients >0.76) except for one condition (3 cm above umbilicus in combined transversus abdominus and curl-up). Test-retest reliability was also very good (intraclass correlation coefficients = 0.78-0.96). Significant differences in inter-recti distance were found, with parous women showing consistently larger values (p < 0.05).

Conclusion: Physiotherapists, following sonographic training, can reliably measure inter-recti distances in both nulliparous and parous women across active and resting tasks. Thus, ultrasound measurement of inter-recti distance is recommended in physiotherapy practice for monitoring diastasis rectus abdominis and assessing rehabilitation progress. However, sub-umbilical inter-recti distance measurements and the impact of co-contraction on reliability require further research.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信