Ana Paula Flôr Alves Nepomuceno, Ana Carolina Cury, Larissa Santos Pinto Pinheiro, George Schayer Sabino, Thales Rezende Souza, Sérgio Teixeira Fonseca, Juliana Melo Ocarino, Renan Alves Resende
{"title":"胸后凸测量仪器的有效性、可靠性和临床实用性:一项系统回顾和荟萃分析。","authors":"Ana Paula Flôr Alves Nepomuceno, Ana Carolina Cury, Larissa Santos Pinto Pinheiro, George Schayer Sabino, Thales Rezende Souza, Sérgio Teixeira Fonseca, Juliana Melo Ocarino, Renan Alves Resende","doi":"10.1016/j.bjpt.2025.101246","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Thoracic hyperkyphosis is related to different health conditions, requiring precise evaluation in clinical settings. Several instruments have been proposed for assessing thoracic kyphosis, and previous studies have investigated their reliability and validity.</p><p><strong>Aims: </strong>Systematically review studies evaluating the validity and reliability of instruments designed to measure thoracic kyphosis and classify their clinical utility.</p><p><strong>Methods: </strong>MEDLINE and EMBASE (via Ovid) databases were used to search studies published until December 2023, and additional searches were conducted in Google Scholar and by hand search. Studies that analyzed the reliability and validity of noninvasive instruments for measuring thoracic kyphosis, regardless of population, study design, and language, were included. Two independent reviewers analyzed the titles, abstracts, and full text and assessed the methodological quality. Clinical utility was assessed using a 10-point scale.</p><p><strong>Results: </strong>Seventy-two studies were included, and 15 instruments had their measurement properties explored: seven were grouped in a meta-analysis for validity, seven for intra-rater reliability, and six for inter-rater reliability. Despite the heterogeneity of estimated data, they presented a strong to moderate correlation with the gold standard and excellent intra- and inter-rater reliability. The instruments most frequently studied were the Flexicurve Angle and the Analog Inclinometer.</p><p><strong>Conclusion: </strong>The meta-analysis demonstrated that the Analog Inclinometer, Flexicurve Angle and Index, Photogrammetry, Smartphone applications, and Spinal Mouse were valid and reliable for assessing thoracic kyphosis. Also, the utility analysis suggested that the Analog Inclinometer, Flexicurve Angle, and Smartphone applications are recommended for clinical settings.</p>","PeriodicalId":49621,"journal":{"name":"Brazilian Journal of Physical Therapy","volume":"29 5","pages":"101246"},"PeriodicalIF":3.2000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12355107/pdf/","citationCount":"0","resultStr":"{\"title\":\"Validity, reliability, and clinical usefulness of instruments for measuring thoracic kyphosis: a systematic review and meta-analysis.\",\"authors\":\"Ana Paula Flôr Alves Nepomuceno, Ana Carolina Cury, Larissa Santos Pinto Pinheiro, George Schayer Sabino, Thales Rezende Souza, Sérgio Teixeira Fonseca, Juliana Melo Ocarino, Renan Alves Resende\",\"doi\":\"10.1016/j.bjpt.2025.101246\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Thoracic hyperkyphosis is related to different health conditions, requiring precise evaluation in clinical settings. Several instruments have been proposed for assessing thoracic kyphosis, and previous studies have investigated their reliability and validity.</p><p><strong>Aims: </strong>Systematically review studies evaluating the validity and reliability of instruments designed to measure thoracic kyphosis and classify their clinical utility.</p><p><strong>Methods: </strong>MEDLINE and EMBASE (via Ovid) databases were used to search studies published until December 2023, and additional searches were conducted in Google Scholar and by hand search. Studies that analyzed the reliability and validity of noninvasive instruments for measuring thoracic kyphosis, regardless of population, study design, and language, were included. Two independent reviewers analyzed the titles, abstracts, and full text and assessed the methodological quality. Clinical utility was assessed using a 10-point scale.</p><p><strong>Results: </strong>Seventy-two studies were included, and 15 instruments had their measurement properties explored: seven were grouped in a meta-analysis for validity, seven for intra-rater reliability, and six for inter-rater reliability. Despite the heterogeneity of estimated data, they presented a strong to moderate correlation with the gold standard and excellent intra- and inter-rater reliability. The instruments most frequently studied were the Flexicurve Angle and the Analog Inclinometer.</p><p><strong>Conclusion: </strong>The meta-analysis demonstrated that the Analog Inclinometer, Flexicurve Angle and Index, Photogrammetry, Smartphone applications, and Spinal Mouse were valid and reliable for assessing thoracic kyphosis. Also, the utility analysis suggested that the Analog Inclinometer, Flexicurve Angle, and Smartphone applications are recommended for clinical settings.</p>\",\"PeriodicalId\":49621,\"journal\":{\"name\":\"Brazilian Journal of Physical Therapy\",\"volume\":\"29 5\",\"pages\":\"101246\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12355107/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Journal of Physical Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.bjpt.2025.101246\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/8/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Physical Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.bjpt.2025.101246","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Validity, reliability, and clinical usefulness of instruments for measuring thoracic kyphosis: a systematic review and meta-analysis.
Introduction: Thoracic hyperkyphosis is related to different health conditions, requiring precise evaluation in clinical settings. Several instruments have been proposed for assessing thoracic kyphosis, and previous studies have investigated their reliability and validity.
Aims: Systematically review studies evaluating the validity and reliability of instruments designed to measure thoracic kyphosis and classify their clinical utility.
Methods: MEDLINE and EMBASE (via Ovid) databases were used to search studies published until December 2023, and additional searches were conducted in Google Scholar and by hand search. Studies that analyzed the reliability and validity of noninvasive instruments for measuring thoracic kyphosis, regardless of population, study design, and language, were included. Two independent reviewers analyzed the titles, abstracts, and full text and assessed the methodological quality. Clinical utility was assessed using a 10-point scale.
Results: Seventy-two studies were included, and 15 instruments had their measurement properties explored: seven were grouped in a meta-analysis for validity, seven for intra-rater reliability, and six for inter-rater reliability. Despite the heterogeneity of estimated data, they presented a strong to moderate correlation with the gold standard and excellent intra- and inter-rater reliability. The instruments most frequently studied were the Flexicurve Angle and the Analog Inclinometer.
Conclusion: The meta-analysis demonstrated that the Analog Inclinometer, Flexicurve Angle and Index, Photogrammetry, Smartphone applications, and Spinal Mouse were valid and reliable for assessing thoracic kyphosis. Also, the utility analysis suggested that the Analog Inclinometer, Flexicurve Angle, and Smartphone applications are recommended for clinical settings.
期刊介绍:
The Brazilian Journal of Physical Therapy (BJPT) is the official publication of the Brazilian Society of Physical Therapy Research and Graduate Studies (ABRAPG-Ft). It publishes original research articles on topics related to the areas of physical therapy and rehabilitation sciences, including clinical, basic or applied studies on the assessment, prevention, and treatment of movement disorders.