Jiaxin Tian, Fengxing Ding, Zhe Wang, Niu Muting, Chen Liu, Zipeng Ye, Huiang Chen, Caizhi Wu, Shaowei Yi, Yubo Fan, Jinzhong Zhao, Shiyi Cao, Bin Ma
{"title":"用于肩袖修复的可吸收生物诱导胶原植入物:我们知道什么,我们需要知道什么,以及前进的道路。","authors":"Jiaxin Tian, Fengxing Ding, Zhe Wang, Niu Muting, Chen Liu, Zipeng Ye, Huiang Chen, Caizhi Wu, Shaowei Yi, Yubo Fan, Jinzhong Zhao, Shiyi Cao, Bin Ma","doi":"10.1111/os.70141","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Rotator cuff injuries are a leading cause of shoulder dysfunction, where bio-inductive collagen implants have demonstrated promising results in promoting tendon regeneration and reducing retear rates. However, existing evidence lacks consistent evaluation across varying follow-up durations, while the specific factors influencing their safety and effectiveness remain undetermined. This study aims to evaluate the quality of evidence regarding the safety, efficacy, and impact factors of applying the resorbable bio-inductive collagen implant clinically to repair rotator cuff injuries.</p><p><strong>Methods: </strong>The study protocol was registered on PROSPERO (CRD42022367522). A systematic literature search of PubMed, Web of Science, Embase, and Cochrane Library (from inception to October 2024) for clinical studies on bio-inductive collagen implants for rotator cuff repair. Two investigators independently screened studies, extracted data, and assessed quality (using RoB1 for RCTs, NOS for cohort studies and JBI critical appraisal tools for case series). Primary outcomes included postoperative tendon thickness, shoulder function scores (ASES/Constant), and re-tear rates. Data were analyzed using random/fixed-effects models to calculate mean differences (MDs) with 95% CIs, with subgroup analyses for tear type, patient age, and postoperative mobilization time. Statistical analyses were performed using Stata 17.0.</p><p><strong>Results: </strong>Seventeen studies were included. The meta-analysis results showed that postoperative tendon thickness of the patients increased statistically compared with the baseline, at 3 months (MD = 2.22; 95% CI: 1.61, 2.83; p < 0.001), 6 months (MD = 2.30; 95% CI: 1.44, 3.16; p < 0.001), 12 months (MD = 2.15; 95% CI: 1.58, 2.72; p < 0.001), and 24 months (MD = 1.05; 95% CI: 0.02, 2.08; p = 0.045). Postoperative shoulder joint function improved significantly. The ASES score and Constant score of the patients were significantly higher than the baseline at 6 months (ASES: MD = 35.90; 95% CI: 32.97, 38.83; p < 0.001), 12 months (ASES: MD = 40.83; 95% CI: 37.56, 44.10; p < 0.001; Constant: MD = 28.59; 95% CI: 21.44, 35.74; p < 0.001), and 24 months (ASES: MD = 39.80; 95% CI: 31.32, 48.27; p < 0.001; Constant: MD = 32.84; 95% CI: 28.72, 36.97; p < 0.001).</p><p><strong>Conclusion: </strong>The bio-inductive collagen implant is effective and safe for healing rotator cuff injuries. Patient age may be an important moderator affecting its efficacy. The impact of tear size and postoperative activities on efficacy needs to be further explored through in-depth clinical studies.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":"2541-2557"},"PeriodicalIF":2.1000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12404871/pdf/","citationCount":"0","resultStr":"{\"title\":\"Resorbable Bio-Inductive Collagen Implant for Rotator Cuff Repair: What We Know, What We Need to Know, and the Path Forward.\",\"authors\":\"Jiaxin Tian, Fengxing Ding, Zhe Wang, Niu Muting, Chen Liu, Zipeng Ye, Huiang Chen, Caizhi Wu, Shaowei Yi, Yubo Fan, Jinzhong Zhao, Shiyi Cao, Bin Ma\",\"doi\":\"10.1111/os.70141\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Rotator cuff injuries are a leading cause of shoulder dysfunction, where bio-inductive collagen implants have demonstrated promising results in promoting tendon regeneration and reducing retear rates. However, existing evidence lacks consistent evaluation across varying follow-up durations, while the specific factors influencing their safety and effectiveness remain undetermined. This study aims to evaluate the quality of evidence regarding the safety, efficacy, and impact factors of applying the resorbable bio-inductive collagen implant clinically to repair rotator cuff injuries.</p><p><strong>Methods: </strong>The study protocol was registered on PROSPERO (CRD42022367522). A systematic literature search of PubMed, Web of Science, Embase, and Cochrane Library (from inception to October 2024) for clinical studies on bio-inductive collagen implants for rotator cuff repair. Two investigators independently screened studies, extracted data, and assessed quality (using RoB1 for RCTs, NOS for cohort studies and JBI critical appraisal tools for case series). Primary outcomes included postoperative tendon thickness, shoulder function scores (ASES/Constant), and re-tear rates. Data were analyzed using random/fixed-effects models to calculate mean differences (MDs) with 95% CIs, with subgroup analyses for tear type, patient age, and postoperative mobilization time. Statistical analyses were performed using Stata 17.0.</p><p><strong>Results: </strong>Seventeen studies were included. The meta-analysis results showed that postoperative tendon thickness of the patients increased statistically compared with the baseline, at 3 months (MD = 2.22; 95% CI: 1.61, 2.83; p < 0.001), 6 months (MD = 2.30; 95% CI: 1.44, 3.16; p < 0.001), 12 months (MD = 2.15; 95% CI: 1.58, 2.72; p < 0.001), and 24 months (MD = 1.05; 95% CI: 0.02, 2.08; p = 0.045). Postoperative shoulder joint function improved significantly. The ASES score and Constant score of the patients were significantly higher than the baseline at 6 months (ASES: MD = 35.90; 95% CI: 32.97, 38.83; p < 0.001), 12 months (ASES: MD = 40.83; 95% CI: 37.56, 44.10; p < 0.001; Constant: MD = 28.59; 95% CI: 21.44, 35.74; p < 0.001), and 24 months (ASES: MD = 39.80; 95% CI: 31.32, 48.27; p < 0.001; Constant: MD = 32.84; 95% CI: 28.72, 36.97; p < 0.001).</p><p><strong>Conclusion: </strong>The bio-inductive collagen implant is effective and safe for healing rotator cuff injuries. Patient age may be an important moderator affecting its efficacy. The impact of tear size and postoperative activities on efficacy needs to be further explored through in-depth clinical studies.</p>\",\"PeriodicalId\":19566,\"journal\":{\"name\":\"Orthopaedic Surgery\",\"volume\":\" \",\"pages\":\"2541-2557\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12404871/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthopaedic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/os.70141\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/8/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.70141","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
目的:肩袖损伤是肩关节功能障碍的主要原因,生物诱导胶原植入物在促进肌腱再生和降低撕裂率方面显示出良好的效果。然而,现有证据缺乏对不同随访时间的一致评价,而影响其安全性和有效性的具体因素仍未确定。本研究旨在评估临床应用可吸收生物诱导胶原植入物修复肩袖损伤的安全性、有效性和影响因素的证据质量。方法:研究方案在PROSPERO上注册(CRD42022367522)。系统检索PubMed, Web of Science, Embase和Cochrane Library(从成立到2024年10月)关于生物诱导胶原植入物用于肩袖修复的临床研究的文献。两名研究者独立筛选研究、提取数据并评估质量(随机对照试验使用RoB1,队列研究使用NOS,病例系列使用JBI关键评估工具)。主要结局包括术后肌腱厚度、肩功能评分(ASES/Constant)和再撕裂率。使用随机/固定效应模型对数据进行分析,计算95% ci的平均差异(MDs),并对撕裂类型、患者年龄和术后活动时间进行亚组分析。采用Stata 17.0进行统计学分析。结果:纳入17项研究。meta分析结果显示,术后3个月时患者肌腱厚度较基线有统计学增加(MD = 2.22;95% ci: 1.61, 2.83;结论:生物诱导胶原蛋白植入治疗肩袖损伤安全有效。患者年龄可能是影响其疗效的重要调节因素。撕裂大小和术后活动对疗效的影响需要通过深入的临床研究进一步探讨。
Resorbable Bio-Inductive Collagen Implant for Rotator Cuff Repair: What We Know, What We Need to Know, and the Path Forward.
Objectives: Rotator cuff injuries are a leading cause of shoulder dysfunction, where bio-inductive collagen implants have demonstrated promising results in promoting tendon regeneration and reducing retear rates. However, existing evidence lacks consistent evaluation across varying follow-up durations, while the specific factors influencing their safety and effectiveness remain undetermined. This study aims to evaluate the quality of evidence regarding the safety, efficacy, and impact factors of applying the resorbable bio-inductive collagen implant clinically to repair rotator cuff injuries.
Methods: The study protocol was registered on PROSPERO (CRD42022367522). A systematic literature search of PubMed, Web of Science, Embase, and Cochrane Library (from inception to October 2024) for clinical studies on bio-inductive collagen implants for rotator cuff repair. Two investigators independently screened studies, extracted data, and assessed quality (using RoB1 for RCTs, NOS for cohort studies and JBI critical appraisal tools for case series). Primary outcomes included postoperative tendon thickness, shoulder function scores (ASES/Constant), and re-tear rates. Data were analyzed using random/fixed-effects models to calculate mean differences (MDs) with 95% CIs, with subgroup analyses for tear type, patient age, and postoperative mobilization time. Statistical analyses were performed using Stata 17.0.
Results: Seventeen studies were included. The meta-analysis results showed that postoperative tendon thickness of the patients increased statistically compared with the baseline, at 3 months (MD = 2.22; 95% CI: 1.61, 2.83; p < 0.001), 6 months (MD = 2.30; 95% CI: 1.44, 3.16; p < 0.001), 12 months (MD = 2.15; 95% CI: 1.58, 2.72; p < 0.001), and 24 months (MD = 1.05; 95% CI: 0.02, 2.08; p = 0.045). Postoperative shoulder joint function improved significantly. The ASES score and Constant score of the patients were significantly higher than the baseline at 6 months (ASES: MD = 35.90; 95% CI: 32.97, 38.83; p < 0.001), 12 months (ASES: MD = 40.83; 95% CI: 37.56, 44.10; p < 0.001; Constant: MD = 28.59; 95% CI: 21.44, 35.74; p < 0.001), and 24 months (ASES: MD = 39.80; 95% CI: 31.32, 48.27; p < 0.001; Constant: MD = 32.84; 95% CI: 28.72, 36.97; p < 0.001).
Conclusion: The bio-inductive collagen implant is effective and safe for healing rotator cuff injuries. Patient age may be an important moderator affecting its efficacy. The impact of tear size and postoperative activities on efficacy needs to be further explored through in-depth clinical studies.
期刊介绍:
Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery.
The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.