Alastair J. Konarski FRCS, MBChB, BSc (Hons) , Leanne Dupley FRCS, MBChB , Nallamilli Rajyalakshmi Reddy MBBS, MS (Orth), MCh (Orth) , Ian A. Trail FRCS, MBChB , Michael J. Walton BMedSci, BMBS, MSc (SEM), FRCS (Tr&Orth) , Stephen Bale FRCS (Orth), MBChB, BSc , Puneet Monga FRCS (Orth), MBBS, DipSEM, MD
{"title":"肩胛骨负重支撑在定制肩关节置换术中的早期临床和放射学结果","authors":"Alastair J. Konarski FRCS, MBChB, BSc (Hons) ,&nbsp;Leanne Dupley FRCS, MBChB ,&nbsp;Nallamilli Rajyalakshmi Reddy MBBS, MS (Orth), MCh (Orth) ,&nbsp;Ian A. Trail FRCS, MBChB ,&nbsp;Michael J. Walton BMedSci, BMBS, MSc (SEM), FRCS (Tr&Orth) ,&nbsp;Stephen Bale FRCS (Orth), MBChB, BSc ,&nbsp;Puneet Monga FRCS (Orth), MBBS, DipSEM, MD","doi":"10.1053/j.sart.2025.03.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Severe glenoid bone deficiency is a challenge in complex primary and revision shoulder arthroplasty, but lately, custom glenoid baseplates have demonstrated good outcomes. Lima Promade 3D-printed implants have recently utilized a strut to load share through the scapular spine to increase stability in patients with the most severe glenoid bone loss. We have assessed early clinical and radiological outcomes and reviewed complications.</div></div><div><h3>Methods</h3><div>This was a retrospective multisurgeon, single-center study, reviewing 19 patients with a minimum 2-year follow-up. Preoperative imaging was assessed for bone loss. Routinely performed postoperative computed tomography (CT) scans, radiographs, and Oxford Shoulder Scores were reviewed. CT scans were reported by independent musculoskeletal radiologists. Patient records were reviewed for any complications.</div></div><div><h3>Results</h3><div>19 patients with a mean age of 66 (42-89) and a mean follow-up of 3.6 years (2-8) were identified. 11 were revision procedures. 14/19 had severe bone loss (Seebauer-Gupta E4/C4) and 5 had severe dysplasia with &gt;30° retroversion (Seebauer-Gupta E3/E4). 16/19 had a postoperative CT scan, with 14 showing good osseointegration; 1 reported partial osseointegration, and 1 suspected loosening but was asymptomatic. One patient had a magnetic resonance imaging scan with no suspicion of loosening. Pre and postoperative Oxford Shoulder Scores were available in 13 patients and improved from a mean of 14/48 preoperatively to 32/48 postoperatively. Complications were reported in 5 patients (26%), with 1 humeral component revision, 2 with limited external rotation, 1 acromial stress fracture, and 1 keloid scarring. No glenoid baseplates required revision.</div></div><div><h3>Discussion</h3><div>This is the first case series to report on the use of a scapular spine strut as part of a custom glenoid baseplate construct. Early outcomes report good osseointegration and good improvements in patient-reported outcome measures. The complication rate in our series was within the range described in the literature for complex shoulder replacement, and we report 100% implant survival at a minimum of 2 years. Early outcomes would suggest this is a safe technique to balance shear forces and improve stability in patients with severe glenoid bone loss and does not appear to increase the risk of acromial stress fractures beyond that reported in the literature. Further study is on-going to assess the medium- and long-term outcomes in these patients.</div></div>","PeriodicalId":39885,"journal":{"name":"Seminars in Arthroplasty","volume":"35 3","pages":"Pages 438-447"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early clinical and radiological outcomes of a scapular spine load-bearing strut in custom glenoid implants for reverse total shoulder arthroplasty\",\"authors\":\"Alastair J. Konarski FRCS, MBChB, BSc (Hons) ,&nbsp;Leanne Dupley FRCS, MBChB ,&nbsp;Nallamilli Rajyalakshmi Reddy MBBS, MS (Orth), MCh (Orth) ,&nbsp;Ian A. Trail FRCS, MBChB ,&nbsp;Michael J. Walton BMedSci, BMBS, MSc (SEM), FRCS (Tr&Orth) ,&nbsp;Stephen Bale FRCS (Orth), MBChB, BSc ,&nbsp;Puneet Monga FRCS (Orth), MBBS, DipSEM, MD\",\"doi\":\"10.1053/j.sart.2025.03.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Severe glenoid bone deficiency is a challenge in complex primary and revision shoulder arthroplasty, but lately, custom glenoid baseplates have demonstrated good outcomes. Lima Promade 3D-printed implants have recently utilized a strut to load share through the scapular spine to increase stability in patients with the most severe glenoid bone loss. We have assessed early clinical and radiological outcomes and reviewed complications.</div></div><div><h3>Methods</h3><div>This was a retrospective multisurgeon, single-center study, reviewing 19 patients with a minimum 2-year follow-up. Preoperative imaging was assessed for bone loss. Routinely performed postoperative computed tomography (CT) scans, radiographs, and Oxford Shoulder Scores were reviewed. CT scans were reported by independent musculoskeletal radiologists. Patient records were reviewed for any complications.</div></div><div><h3>Results</h3><div>19 patients with a mean age of 66 (42-89) and a mean follow-up of 3.6 years (2-8) were identified. 11 were revision procedures. 14/19 had severe bone loss (Seebauer-Gupta E4/C4) and 5 had severe dysplasia with &gt;30° retroversion (Seebauer-Gupta E3/E4). 16/19 had a postoperative CT scan, with 14 showing good osseointegration; 1 reported partial osseointegration, and 1 suspected loosening but was asymptomatic. One patient had a magnetic resonance imaging scan with no suspicion of loosening. Pre and postoperative Oxford Shoulder Scores were available in 13 patients and improved from a mean of 14/48 preoperatively to 32/48 postoperatively. Complications were reported in 5 patients (26%), with 1 humeral component revision, 2 with limited external rotation, 1 acromial stress fracture, and 1 keloid scarring. No glenoid baseplates required revision.</div></div><div><h3>Discussion</h3><div>This is the first case series to report on the use of a scapular spine strut as part of a custom glenoid baseplate construct. Early outcomes report good osseointegration and good improvements in patient-reported outcome measures. The complication rate in our series was within the range described in the literature for complex shoulder replacement, and we report 100% implant survival at a minimum of 2 years. Early outcomes would suggest this is a safe technique to balance shear forces and improve stability in patients with severe glenoid bone loss and does not appear to increase the risk of acromial stress fractures beyond that reported in the literature. Further study is on-going to assess the medium- and long-term outcomes in these patients.</div></div>\",\"PeriodicalId\":39885,\"journal\":{\"name\":\"Seminars in Arthroplasty\",\"volume\":\"35 3\",\"pages\":\"Pages 438-447\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in Arthroplasty\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1045452725000483\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1045452725000483","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:严重的盂骨缺损在复杂的初次和翻修肩关节置换术中是一个挑战,但最近,定制盂骨基板显示出良好的效果。Lima Promade 3d打印植入物最近利用支柱通过肩胛骨负荷分担,以增加最严重肩胛骨丢失患者的稳定性。我们评估了早期临床和放射学结果,并回顾了并发症。方法本研究是一项多外科医生、单中心的回顾性研究,对19例患者进行了至少2年的随访。术前影像学检查骨质流失情况。术后常规计算机断层扫描(CT)、x线片和牛津肩部评分进行了回顾。CT扫描由独立的肌肉骨骼放射科医生报告。检查了病人的病历,看是否有并发症。结果19例患者平均年龄66岁(42 ~ 89岁),平均随访3.6年(2 ~ 8年)。11项为修订程序。14/19严重骨质流失(Seebauer-Gupta E4/C4), 5例严重发育不良伴>;30°逆行(Seebauer-Gupta E3/E4)。16/19术后CT扫描,14例骨融合良好;1例报告部分骨整合,1例怀疑松动,但无症状。一名患者进行了磁共振成像扫描,没有怀疑松动。13例患者获得了术前和术后牛津肩部评分,从术前的平均14/48提高到术后的32/48。5例(26%)患者出现并发症,1例肱骨假体翻修,2例外旋受限,1例肩峰应力性骨折,1例瘢痕形成。无关节盂底板需要翻修。讨论:这是第一个使用肩胛骨支撑作为定制盂底板结构的病例系列报道。早期结果报告良好的骨融合和患者报告的结果测量的良好改善。在我们的研究中,复杂肩关节置换术的并发症发生率在文献中描述的范围内,我们报告了至少2年的100%假体存活率。早期结果表明,这是一种安全的技术,可以平衡剪切力,提高严重盂骨丢失患者的稳定性,而且除了文献报道外,似乎不会增加肩峰应力性骨折的风险。进一步的研究正在评估这些患者的中期和长期结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Early clinical and radiological outcomes of a scapular spine load-bearing strut in custom glenoid implants for reverse total shoulder arthroplasty

Background

Severe glenoid bone deficiency is a challenge in complex primary and revision shoulder arthroplasty, but lately, custom glenoid baseplates have demonstrated good outcomes. Lima Promade 3D-printed implants have recently utilized a strut to load share through the scapular spine to increase stability in patients with the most severe glenoid bone loss. We have assessed early clinical and radiological outcomes and reviewed complications.

Methods

This was a retrospective multisurgeon, single-center study, reviewing 19 patients with a minimum 2-year follow-up. Preoperative imaging was assessed for bone loss. Routinely performed postoperative computed tomography (CT) scans, radiographs, and Oxford Shoulder Scores were reviewed. CT scans were reported by independent musculoskeletal radiologists. Patient records were reviewed for any complications.

Results

19 patients with a mean age of 66 (42-89) and a mean follow-up of 3.6 years (2-8) were identified. 11 were revision procedures. 14/19 had severe bone loss (Seebauer-Gupta E4/C4) and 5 had severe dysplasia with >30° retroversion (Seebauer-Gupta E3/E4). 16/19 had a postoperative CT scan, with 14 showing good osseointegration; 1 reported partial osseointegration, and 1 suspected loosening but was asymptomatic. One patient had a magnetic resonance imaging scan with no suspicion of loosening. Pre and postoperative Oxford Shoulder Scores were available in 13 patients and improved from a mean of 14/48 preoperatively to 32/48 postoperatively. Complications were reported in 5 patients (26%), with 1 humeral component revision, 2 with limited external rotation, 1 acromial stress fracture, and 1 keloid scarring. No glenoid baseplates required revision.

Discussion

This is the first case series to report on the use of a scapular spine strut as part of a custom glenoid baseplate construct. Early outcomes report good osseointegration and good improvements in patient-reported outcome measures. The complication rate in our series was within the range described in the literature for complex shoulder replacement, and we report 100% implant survival at a minimum of 2 years. Early outcomes would suggest this is a safe technique to balance shear forces and improve stability in patients with severe glenoid bone loss and does not appear to increase the risk of acromial stress fractures beyond that reported in the literature. Further study is on-going to assess the medium- and long-term outcomes in these patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Seminars in Arthroplasty
Seminars in Arthroplasty Medicine-Surgery
CiteScore
1.00
自引率
0.00%
发文量
104
期刊介绍: Each issue of Seminars in Arthroplasty provides a comprehensive, current overview of a single topic in arthroplasty. The journal addresses orthopedic surgeons, providing authoritative reviews with emphasis on new developments relevant to their practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信