在屋顶线上追逐传导间隙:邻近和重叠优于附肢起搏。

IF 9.8 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Takamitsu Takagi, Osamu Inaba, Yukihiro Inamura, Akira Sato, Yuhei Isonaga, Shinichi Tachibana, Hiroaki Ohya, Allan Plant, Romain Tixier, Josselin Duchateau, Nicolas Derval, Frédéric Sacher, Mélèze Hocini, Pierre Jaïs, Michel Haïssaguerre, Thomas Pambrun
{"title":"在屋顶线上追逐传导间隙:邻近和重叠优于附肢起搏。","authors":"Takamitsu Takagi, Osamu Inaba, Yukihiro Inamura, Akira Sato, Yuhei Isonaga, Shinichi Tachibana, Hiroaki Ohya, Allan Plant, Romain Tixier, Josselin Duchateau, Nicolas Derval, Frédéric Sacher, Mélèze Hocini, Pierre Jaïs, Michel Haïssaguerre, Thomas Pambrun","doi":"10.1161/CIRCEP.124.013713","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Blocking a line depends not only on the ablation but also on the validation technique. We sought to compare the performance of different pacing modes for roof line validation.</p><p><strong>Methods: </strong>Fifty consecutive patients underwent atrial fibrillation ablation, which included a roof line and a floor line. Floor line block was mandatory for clear evaluation of the roof line, the block of which was demonstrated by a box isolation of the dome. Before floor line creation, first-pass roof line evaluation was based on high-density mapping while pacing from either: (1) the left appendage; (2) just above the line; or (3) with an overlapping multispline catheter.</p><p><strong>Results: </strong>Roof line mapping was feasible in all patients (100%) during left appendage and nearby pacing, and in 45 (90%) patients during overlap pacing. Left appendage pacing sensitivity for true gaps was significantly lower than nearby (48% versus 97%; <i>P</i><0.001) and overlap (48% versus 93%; <i>P</i><0.001) pacing. Left appendage pacing negative predictive value for true block was significantly lower than nearby (50% versus 94%; <i>P</i>=0.001) and overlap (50% versus 89%; <i>P</i>=0.004) pacing. Double potentials during left appendage pacing were shorter than during nearby pacing (63±20 ms versus 103±22 ms; <i>P</i><0.001). In 1 patient, a slow conduction gap was unmasked only after floor line block. Final box isolation of the dome was achieved in 47 (94%) patients.</p><p><strong>Conclusions: </strong>The longer the activation delay from one side of a line to the other, the greater the chance to unmask a slow conduction gap across the line. Nearby pacing thus better identifies roof line gaps than left appendage pacing. Overlap pacing offers a simple and fast alternative with similar performance.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e013713"},"PeriodicalIF":9.8000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Chasing Conduction Gaps Across the Roof Line: Nearby and Overlap Better Than Appendage Pacing.\",\"authors\":\"Takamitsu Takagi, Osamu Inaba, Yukihiro Inamura, Akira Sato, Yuhei Isonaga, Shinichi Tachibana, Hiroaki Ohya, Allan Plant, Romain Tixier, Josselin Duchateau, Nicolas Derval, Frédéric Sacher, Mélèze Hocini, Pierre Jaïs, Michel Haïssaguerre, Thomas Pambrun\",\"doi\":\"10.1161/CIRCEP.124.013713\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Blocking a line depends not only on the ablation but also on the validation technique. We sought to compare the performance of different pacing modes for roof line validation.</p><p><strong>Methods: </strong>Fifty consecutive patients underwent atrial fibrillation ablation, which included a roof line and a floor line. Floor line block was mandatory for clear evaluation of the roof line, the block of which was demonstrated by a box isolation of the dome. Before floor line creation, first-pass roof line evaluation was based on high-density mapping while pacing from either: (1) the left appendage; (2) just above the line; or (3) with an overlapping multispline catheter.</p><p><strong>Results: </strong>Roof line mapping was feasible in all patients (100%) during left appendage and nearby pacing, and in 45 (90%) patients during overlap pacing. Left appendage pacing sensitivity for true gaps was significantly lower than nearby (48% versus 97%; <i>P</i><0.001) and overlap (48% versus 93%; <i>P</i><0.001) pacing. Left appendage pacing negative predictive value for true block was significantly lower than nearby (50% versus 94%; <i>P</i>=0.001) and overlap (50% versus 89%; <i>P</i>=0.004) pacing. Double potentials during left appendage pacing were shorter than during nearby pacing (63±20 ms versus 103±22 ms; <i>P</i><0.001). In 1 patient, a slow conduction gap was unmasked only after floor line block. Final box isolation of the dome was achieved in 47 (94%) patients.</p><p><strong>Conclusions: </strong>The longer the activation delay from one side of a line to the other, the greater the chance to unmask a slow conduction gap across the line. Nearby pacing thus better identifies roof line gaps than left appendage pacing. Overlap pacing offers a simple and fast alternative with similar performance.</p>\",\"PeriodicalId\":10319,\"journal\":{\"name\":\"Circulation. Arrhythmia and electrophysiology\",\"volume\":\" \",\"pages\":\"e013713\"},\"PeriodicalIF\":9.8000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Circulation. Arrhythmia and electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1161/CIRCEP.124.013713\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/7/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.124.013713","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:阻断一条线不仅取决于消融,还取决于验证技术。我们试图比较不同的起搏模式车顶线验证的性能。方法:连续50例患者行房颤消融术,包括顶线和底线。为了清晰地评估屋顶线,地板线块是强制性的,屋顶线块通过圆顶的盒子隔离来展示。在地板线创建之前,第一次通过屋顶线评估是基于高密度映射,同时从以下两种方式起跳:(1)左侧附属物;(二)略高于直线;或(3)用重叠的多样条导管。结果:所有患者(100%)在左附件及附近起搏时,屋顶线测绘是可行的;45例患者(90%)在重叠起搏时,屋顶线测绘是可行的。左附肢对真实间隙的起搏敏感性显著低于附近间隙(48%对97%;PPP=0.001)和重叠(50%对89%;P = 0.004)踱来踱去。左附件起搏时双电位短于附近起搏时(63±20 ms vs 103±22 ms);结论:从一条线的一边到另一边的激活延迟越长,越有可能揭示一条线上缓慢的传导间隙。因此,与左附件起搏相比,附近起搏能更好地识别屋顶线间隙。重叠节奏提供了一个简单而快速的替代方案,具有类似的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Chasing Conduction Gaps Across the Roof Line: Nearby and Overlap Better Than Appendage Pacing.

Background: Blocking a line depends not only on the ablation but also on the validation technique. We sought to compare the performance of different pacing modes for roof line validation.

Methods: Fifty consecutive patients underwent atrial fibrillation ablation, which included a roof line and a floor line. Floor line block was mandatory for clear evaluation of the roof line, the block of which was demonstrated by a box isolation of the dome. Before floor line creation, first-pass roof line evaluation was based on high-density mapping while pacing from either: (1) the left appendage; (2) just above the line; or (3) with an overlapping multispline catheter.

Results: Roof line mapping was feasible in all patients (100%) during left appendage and nearby pacing, and in 45 (90%) patients during overlap pacing. Left appendage pacing sensitivity for true gaps was significantly lower than nearby (48% versus 97%; P<0.001) and overlap (48% versus 93%; P<0.001) pacing. Left appendage pacing negative predictive value for true block was significantly lower than nearby (50% versus 94%; P=0.001) and overlap (50% versus 89%; P=0.004) pacing. Double potentials during left appendage pacing were shorter than during nearby pacing (63±20 ms versus 103±22 ms; P<0.001). In 1 patient, a slow conduction gap was unmasked only after floor line block. Final box isolation of the dome was achieved in 47 (94%) patients.

Conclusions: The longer the activation delay from one side of a line to the other, the greater the chance to unmask a slow conduction gap across the line. Nearby pacing thus better identifies roof line gaps than left appendage pacing. Overlap pacing offers a simple and fast alternative with similar performance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信