有监督GAN与无监督GAN在脑磁共振引导放疗中伪ct合成的比较。

IF 2 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Milad Zeinali Kermani, Mohamad Bagher Tavakoli, Amir Khorasani, Iraj Abedi, Vahid Sadeghi, Alireza Amouheidari
{"title":"有监督GAN与无监督GAN在脑磁共振引导放疗中伪ct合成的比较。","authors":"Milad Zeinali Kermani, Mohamad Bagher Tavakoli, Amir Khorasani, Iraj Abedi, Vahid Sadeghi, Alireza Amouheidari","doi":"10.1007/s13246-025-01606-1","DOIUrl":null,"url":null,"abstract":"<p><p>Radiotherapy is a crucial treatment for brain tumor malignancies. To address the limitations of CT-based treatment planning, recent research has explored MR-only radiotherapy, requiring precise MR-to-CT synthesis. This study compares two deep learning approaches, supervised (Pix2Pix) and unsupervised (CycleGAN), for generating pseudo-CT (pCT) images from T1- and T2-weighted MR sequences. 3270 paired T1- and T2-weighted MRI images were collected and registered with corresponding CT images. After preprocessing, a supervised pCT generative model was trained using the Pix2Pix framework, and an unsupervised generative network (CycleGAN) was also trained to enable a comparative assessment of pCT quality relative to the Pix2Pix model. To assess differences between pCT and reference CT images, three key metrics (SSIM, PSNR, and MAE) were used. Additionally, a dosimetric evaluation was performed on selected cases to assess clinical relevance. The average SSIM, PSNR, and MAE for Pix2Pix on T1 images were 0.964 ± 0.03, 32.812 ± 5.21, and 79.681 ± 9.52 HU, respectively. Statistical analysis revealed that Pix2Pix significantly outperformed CycleGAN in generating high-fidelity pCT images (p < 0.05). There was no notable difference in the effectiveness of T1-weighted versus T2-weighted MR images for generating pCT (p > 0.05). Dosimetric evaluation confirmed comparable dose distributions between pCT and reference CT, supporting clinical feasibility. Both supervised and unsupervised methods demonstrated the capability to generate accurate pCT images from conventional T1- and T2-weighted MR sequences. While supervised methods like Pix2Pix achieve higher accuracy, unsupervised approaches such as CycleGAN offer greater flexibility by eliminating the need for paired training data, making them suitable for applications where paired data is unavailable.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Supervised versus unsupervised GAN for pseudo-CT synthesis in brain MR-guided radiotherapy.\",\"authors\":\"Milad Zeinali Kermani, Mohamad Bagher Tavakoli, Amir Khorasani, Iraj Abedi, Vahid Sadeghi, Alireza Amouheidari\",\"doi\":\"10.1007/s13246-025-01606-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Radiotherapy is a crucial treatment for brain tumor malignancies. To address the limitations of CT-based treatment planning, recent research has explored MR-only radiotherapy, requiring precise MR-to-CT synthesis. This study compares two deep learning approaches, supervised (Pix2Pix) and unsupervised (CycleGAN), for generating pseudo-CT (pCT) images from T1- and T2-weighted MR sequences. 3270 paired T1- and T2-weighted MRI images were collected and registered with corresponding CT images. After preprocessing, a supervised pCT generative model was trained using the Pix2Pix framework, and an unsupervised generative network (CycleGAN) was also trained to enable a comparative assessment of pCT quality relative to the Pix2Pix model. To assess differences between pCT and reference CT images, three key metrics (SSIM, PSNR, and MAE) were used. Additionally, a dosimetric evaluation was performed on selected cases to assess clinical relevance. The average SSIM, PSNR, and MAE for Pix2Pix on T1 images were 0.964 ± 0.03, 32.812 ± 5.21, and 79.681 ± 9.52 HU, respectively. Statistical analysis revealed that Pix2Pix significantly outperformed CycleGAN in generating high-fidelity pCT images (p < 0.05). There was no notable difference in the effectiveness of T1-weighted versus T2-weighted MR images for generating pCT (p > 0.05). Dosimetric evaluation confirmed comparable dose distributions between pCT and reference CT, supporting clinical feasibility. Both supervised and unsupervised methods demonstrated the capability to generate accurate pCT images from conventional T1- and T2-weighted MR sequences. While supervised methods like Pix2Pix achieve higher accuracy, unsupervised approaches such as CycleGAN offer greater flexibility by eliminating the need for paired training data, making them suitable for applications where paired data is unavailable.</p>\",\"PeriodicalId\":48490,\"journal\":{\"name\":\"Physical and Engineering Sciences in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2025-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical and Engineering Sciences in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s13246-025-01606-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-025-01606-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

放射治疗是脑肿瘤恶性肿瘤的重要治疗手段。为了解决基于ct的治疗计划的局限性,最近的研究已经探索了仅mr放射治疗,需要精确的mr - ct合成。本研究比较了两种深度学习方法,有监督(Pix2Pix)和无监督(CycleGAN),用于从T1和t2加权MR序列中生成伪ct (pCT)图像。收集3270张配对的T1和t2加权MRI图像,并与相应的CT图像进行配准。预处理后,使用Pix2Pix框架训练监督pCT生成模型,并训练无监督生成网络(CycleGAN),以便相对于Pix2Pix模型对pCT质量进行比较评估。为了评估pCT和参考CT图像之间的差异,使用了三个关键指标(SSIM, PSNR和MAE)。此外,对选定病例进行剂量学评估以评估临床相关性。Pix2Pix在T1图像上的平均SSIM、PSNR和MAE分别为0.964±0.03、32.812±5.21和79.681±9.52 HU。统计分析显示,Pix2Pix在生成高保真pCT图像方面明显优于CycleGAN (p 0.05)。剂量学评估证实了pCT和参考CT之间的剂量分布可比较,支持临床可行性。监督和非监督方法都证明了从常规T1和t2加权MR序列生成准确pCT图像的能力。虽然像Pix2Pix这样的监督方法实现了更高的准确性,但像CycleGAN这样的无监督方法通过消除对成对训练数据的需求提供了更大的灵活性,使其适用于无法获得成对数据的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Supervised versus unsupervised GAN for pseudo-CT synthesis in brain MR-guided radiotherapy.

Radiotherapy is a crucial treatment for brain tumor malignancies. To address the limitations of CT-based treatment planning, recent research has explored MR-only radiotherapy, requiring precise MR-to-CT synthesis. This study compares two deep learning approaches, supervised (Pix2Pix) and unsupervised (CycleGAN), for generating pseudo-CT (pCT) images from T1- and T2-weighted MR sequences. 3270 paired T1- and T2-weighted MRI images were collected and registered with corresponding CT images. After preprocessing, a supervised pCT generative model was trained using the Pix2Pix framework, and an unsupervised generative network (CycleGAN) was also trained to enable a comparative assessment of pCT quality relative to the Pix2Pix model. To assess differences between pCT and reference CT images, three key metrics (SSIM, PSNR, and MAE) were used. Additionally, a dosimetric evaluation was performed on selected cases to assess clinical relevance. The average SSIM, PSNR, and MAE for Pix2Pix on T1 images were 0.964 ± 0.03, 32.812 ± 5.21, and 79.681 ± 9.52 HU, respectively. Statistical analysis revealed that Pix2Pix significantly outperformed CycleGAN in generating high-fidelity pCT images (p < 0.05). There was no notable difference in the effectiveness of T1-weighted versus T2-weighted MR images for generating pCT (p > 0.05). Dosimetric evaluation confirmed comparable dose distributions between pCT and reference CT, supporting clinical feasibility. Both supervised and unsupervised methods demonstrated the capability to generate accurate pCT images from conventional T1- and T2-weighted MR sequences. While supervised methods like Pix2Pix achieve higher accuracy, unsupervised approaches such as CycleGAN offer greater flexibility by eliminating the need for paired training data, making them suitable for applications where paired data is unavailable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信