{"title":"一种新的基于免疫沉淀的靶向液相色谱-串联质谱分析方法用于准确测定人血清中copeptin。","authors":"Danni Mu, Xiaoli Ma, Yichen Ma, Danchen Wang, Yutong Zou, Ying Zhu, Jian Zhong, Dandan Sun, Yicong Yin, Yumeng Gao, Yuemeng Li, Shi Chen, Huijuan Zhu, Songlin Yu, Ling Qiu, Xinqi Cheng","doi":"10.1515/cclm-2025-0022","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Copeptin, a stable and simple-to-measure surrogate marker for arginine vasopressin (AVP), demonstrates excellent clinical values, particularly in diagnosing polyuria-polydipsia syndromes. However, conventional immunoassay methods are limited and lack comparability. Our aim was to establish a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying copeptin in human serum.</p><p><strong>Methods: </strong>Copeptin was extracted from serum using immunoprecipitation, digested with trypsin, and prepared using anion exchange solid-phase extraction before LC-MS/MS detection. The analytical performance was validated in accordance with current guidelines. The method was compared to an immunofluorescent assay on the B.R.A.H.M.S platform.</p><p><strong>Results: </strong>The LC-MS/MS method had a runtime of 8.5 min. The within-run precision ranged from 5.2 to 12.1 %, and total coefficients of variation ranged from 8.1 to 13.5 %. Copeptin quantitation showed linearity within the range of 5-1,000 pg/mL, with a limit of detection of 2.5 pg/mL. Recovery rates ranged from 95.2 to 103.1 %, and no significant matrix effect was observed with internal standard correction. The LC-MS/MS method had a good consistency with the immunoassay (r=0.926, slope=0.989). The reference interval for healthy individuals was 3.66-58.25 pg/mL.</p><p><strong>Conclusions: </strong>We demonstrated the accuracy and reliability of this targeted LC-MS/MS method for quantifying copeptin. This innovative application showed satisfactory precision, a wide linear range, and a low limit of detection. Clinical studies are anticipated to be conducted to assess diagnostic accuracy using this method.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel immunoprecipitation-based targeted liquid chromatography-tandem mass spectrometry analysis for accurate determination for copeptin in human serum.\",\"authors\":\"Danni Mu, Xiaoli Ma, Yichen Ma, Danchen Wang, Yutong Zou, Ying Zhu, Jian Zhong, Dandan Sun, Yicong Yin, Yumeng Gao, Yuemeng Li, Shi Chen, Huijuan Zhu, Songlin Yu, Ling Qiu, Xinqi Cheng\",\"doi\":\"10.1515/cclm-2025-0022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Copeptin, a stable and simple-to-measure surrogate marker for arginine vasopressin (AVP), demonstrates excellent clinical values, particularly in diagnosing polyuria-polydipsia syndromes. However, conventional immunoassay methods are limited and lack comparability. Our aim was to establish a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying copeptin in human serum.</p><p><strong>Methods: </strong>Copeptin was extracted from serum using immunoprecipitation, digested with trypsin, and prepared using anion exchange solid-phase extraction before LC-MS/MS detection. The analytical performance was validated in accordance with current guidelines. The method was compared to an immunofluorescent assay on the B.R.A.H.M.S platform.</p><p><strong>Results: </strong>The LC-MS/MS method had a runtime of 8.5 min. The within-run precision ranged from 5.2 to 12.1 %, and total coefficients of variation ranged from 8.1 to 13.5 %. Copeptin quantitation showed linearity within the range of 5-1,000 pg/mL, with a limit of detection of 2.5 pg/mL. Recovery rates ranged from 95.2 to 103.1 %, and no significant matrix effect was observed with internal standard correction. The LC-MS/MS method had a good consistency with the immunoassay (r=0.926, slope=0.989). The reference interval for healthy individuals was 3.66-58.25 pg/mL.</p><p><strong>Conclusions: </strong>We demonstrated the accuracy and reliability of this targeted LC-MS/MS method for quantifying copeptin. This innovative application showed satisfactory precision, a wide linear range, and a low limit of detection. Clinical studies are anticipated to be conducted to assess diagnostic accuracy using this method.</p>\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2025-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2025-0022\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2025-0022","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
A novel immunoprecipitation-based targeted liquid chromatography-tandem mass spectrometry analysis for accurate determination for copeptin in human serum.
Objectives: Copeptin, a stable and simple-to-measure surrogate marker for arginine vasopressin (AVP), demonstrates excellent clinical values, particularly in diagnosing polyuria-polydipsia syndromes. However, conventional immunoassay methods are limited and lack comparability. Our aim was to establish a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying copeptin in human serum.
Methods: Copeptin was extracted from serum using immunoprecipitation, digested with trypsin, and prepared using anion exchange solid-phase extraction before LC-MS/MS detection. The analytical performance was validated in accordance with current guidelines. The method was compared to an immunofluorescent assay on the B.R.A.H.M.S platform.
Results: The LC-MS/MS method had a runtime of 8.5 min. The within-run precision ranged from 5.2 to 12.1 %, and total coefficients of variation ranged from 8.1 to 13.5 %. Copeptin quantitation showed linearity within the range of 5-1,000 pg/mL, with a limit of detection of 2.5 pg/mL. Recovery rates ranged from 95.2 to 103.1 %, and no significant matrix effect was observed with internal standard correction. The LC-MS/MS method had a good consistency with the immunoassay (r=0.926, slope=0.989). The reference interval for healthy individuals was 3.66-58.25 pg/mL.
Conclusions: We demonstrated the accuracy and reliability of this targeted LC-MS/MS method for quantifying copeptin. This innovative application showed satisfactory precision, a wide linear range, and a low limit of detection. Clinical studies are anticipated to be conducted to assess diagnostic accuracy using this method.
期刊介绍:
Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically.
CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France).
Topics:
- clinical biochemistry
- clinical genomics and molecular biology
- clinical haematology and coagulation
- clinical immunology and autoimmunity
- clinical microbiology
- drug monitoring and analysis
- evaluation of diagnostic biomarkers
- disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes)
- new reagents, instrumentation and technologies
- new methodologies
- reference materials and methods
- reference values and decision limits
- quality and safety in laboratory medicine
- translational laboratory medicine
- clinical metrology
Follow @cclm_degruyter on Twitter!