解决乳房缩小后高骑行NAC的难题:一种新的解决方案和技术综述。

IF 1.5 Q4 SURGERY
Indian Journal of Plastic Surgery Pub Date : 2025-03-05 eCollection Date: 2025-06-01 DOI:10.1055/s-0045-1804926
Rajat Gupta, Priya Bansal, Neharika Neeraj
{"title":"解决乳房缩小后高骑行NAC的难题:一种新的解决方案和技术综述。","authors":"Rajat Gupta, Priya Bansal, Neharika Neeraj","doi":"10.1055/s-0045-1804926","DOIUrl":null,"url":null,"abstract":"<p><p>High-riding nipple-areolar complex (NAC) due to postoperative malposition following breast reduction surgery is a very serious aesthetic problem for the patients and a very difficult one for surgeons to correct. Reduction surgeries aim to elevate the NAC, and the best course of action for avoiding a high-riding NAC is prevention of over-elevation, taking care of marking the appropriate distance between the NAC and the inferior mammary fold. Its correction poses a very difficult challenge due to the limited skin between the upper edge of the NAC and the sternal notch and the concern for avoiding scars that lie above the nipple in the superior pole of the breast. There are various techniques described for repositioning the NAC to an acceptable position, but most of them come with the drawback of unsatisfactory correction of bottoming out, additional scars, and multiple stages. A technique of mastopexy called \"two-flap technique\" including repositioning of the NAC as well as elevation of inferior breast mound (or correction of bottoming out), without any additional scars, is described in this article.</p>","PeriodicalId":47204,"journal":{"name":"Indian Journal of Plastic Surgery","volume":"58 3","pages":"233-236"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12213022/pdf/","citationCount":"0","resultStr":"{\"title\":\"Addressing the Challenging Problem of High-Riding NAC after Breast Reduction: A Novel Solution and Review of Techniques.\",\"authors\":\"Rajat Gupta, Priya Bansal, Neharika Neeraj\",\"doi\":\"10.1055/s-0045-1804926\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>High-riding nipple-areolar complex (NAC) due to postoperative malposition following breast reduction surgery is a very serious aesthetic problem for the patients and a very difficult one for surgeons to correct. Reduction surgeries aim to elevate the NAC, and the best course of action for avoiding a high-riding NAC is prevention of over-elevation, taking care of marking the appropriate distance between the NAC and the inferior mammary fold. Its correction poses a very difficult challenge due to the limited skin between the upper edge of the NAC and the sternal notch and the concern for avoiding scars that lie above the nipple in the superior pole of the breast. There are various techniques described for repositioning the NAC to an acceptable position, but most of them come with the drawback of unsatisfactory correction of bottoming out, additional scars, and multiple stages. A technique of mastopexy called \\\"two-flap technique\\\" including repositioning of the NAC as well as elevation of inferior breast mound (or correction of bottoming out), without any additional scars, is described in this article.</p>\",\"PeriodicalId\":47204,\"journal\":{\"name\":\"Indian Journal of Plastic Surgery\",\"volume\":\"58 3\",\"pages\":\"233-236\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12213022/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Plastic Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0045-1804926\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/6/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Plastic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0045-1804926","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

乳晕复合体(NAC)是乳房缩乳手术后因位置错位引起的严重的审美问题,也是外科医生难以纠正的问题。复位手术的目的是抬高NAC,避免NAC过高的最佳措施是防止NAC过高,注意标记NAC与下乳褶之间的适当距离。由于NAC上边缘和胸骨切迹之间的皮肤有限而且要避免乳房上极乳头上方的疤痕,所以矫正起来非常困难。有各种各样的技术可以将NAC重新定位到一个可接受的位置,但它们中的大多数都有缺点,即不满意的底部矫正,额外的疤痕和多阶段。本文描述了一种称为“双瓣技术”的乳房固定术,包括NAC的重新定位以及下乳房丘的抬高(或底部的矫正),没有任何额外的疤痕。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Addressing the Challenging Problem of High-Riding NAC after Breast Reduction: A Novel Solution and Review of Techniques.

High-riding nipple-areolar complex (NAC) due to postoperative malposition following breast reduction surgery is a very serious aesthetic problem for the patients and a very difficult one for surgeons to correct. Reduction surgeries aim to elevate the NAC, and the best course of action for avoiding a high-riding NAC is prevention of over-elevation, taking care of marking the appropriate distance between the NAC and the inferior mammary fold. Its correction poses a very difficult challenge due to the limited skin between the upper edge of the NAC and the sternal notch and the concern for avoiding scars that lie above the nipple in the superior pole of the breast. There are various techniques described for repositioning the NAC to an acceptable position, but most of them come with the drawback of unsatisfactory correction of bottoming out, additional scars, and multiple stages. A technique of mastopexy called "two-flap technique" including repositioning of the NAC as well as elevation of inferior breast mound (or correction of bottoming out), without any additional scars, is described in this article.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.80
自引率
12.50%
发文量
64
审稿时长
27 weeks
期刊介绍: Indian Journal of Plastic Surgery (ISSN : 0970-0358) is biannual publication of the Association of Plastic Surgeons of India. Bibliographic listings: The journal is indexed with Bioline International, Caspur, DOAJ, EBSCO Publishing’s Electronic Databases, Expanded Academic ASAP, Genamics JournalSeek, Google Scholar, Health & Wellness Research Center, Health Reference Center Academic, Hinari, Index Copernicus, IndMed, OpenJGate, PubMed, Pubmed Central, Scimago Journal Ranking, SCOLOAR, SCOPUS, SIIC databases, SNEMB, Ulrich’s International Periodical Directory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信