Tanvi Rao, Vijay Jaganathan, Jonathan Victor, Pappu Paramartha Lingam
{"title":"旋髂浅动脉穿支解剖特征的尸体研究。","authors":"Tanvi Rao, Vijay Jaganathan, Jonathan Victor, Pappu Paramartha Lingam","doi":"10.1055/s-0045-1802643","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b> The superficial circumflex iliac artery perforator flap (SCIP flap) is an evolution of the conventional free groin flap. Even though the anatomical basis for SCIP flap is well established in general, the same is not described in a South Indian population. <b>Objectives</b> The objectives of our study were to determine the anatomical variations of the superficial circumflex iliac artery perforators (SCIA perforators) and describe them in relation to the nearby bony landmarks like anterior superior iliac spine (ASIS) and pubic tubercle (PT). <b>Materials and Methods</b> This observational study was done between October 2020 and December 2021. Cadaveric dissection was done and the required anatomic data were collected. <b>Results</b> The mean diameter of SCIA was 0.99 mm and the mean pedicle length was 2.97 cm. The average diameters of the medial and lateral perforators were 0.63 and 0.55 mm, respectively. The pedicle lengths of the medial and lateral perforators were 3.03 and 4.31 cm, respectively. The medial perforator was 5.63 cm lateral and 1.66 cm superior to the PT. It was 5.37 cm medial and 5.99 cm inferior to the ASIS. The lateral perforator was 7.97 cm lateral and 2.73 cm superior to the PT. It was 2.86 cm medial and 4.11 cm inferior to the ASIS. <b>Conclusion</b> Finding the exact location of the medial and the lateral perforators with respect to permanent bony landmarks and having an idea about their average pedicle length are useful for preoperative planning of the SCIP flap.</p>","PeriodicalId":47204,"journal":{"name":"Indian Journal of Plastic Surgery","volume":"58 3","pages":"199-205"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12213017/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Cadaveric Study of the Anatomical Characteristics of the Superficial Circumflex Iliac Artery Perforator.\",\"authors\":\"Tanvi Rao, Vijay Jaganathan, Jonathan Victor, Pappu Paramartha Lingam\",\"doi\":\"10.1055/s-0045-1802643\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background</b> The superficial circumflex iliac artery perforator flap (SCIP flap) is an evolution of the conventional free groin flap. Even though the anatomical basis for SCIP flap is well established in general, the same is not described in a South Indian population. <b>Objectives</b> The objectives of our study were to determine the anatomical variations of the superficial circumflex iliac artery perforators (SCIA perforators) and describe them in relation to the nearby bony landmarks like anterior superior iliac spine (ASIS) and pubic tubercle (PT). <b>Materials and Methods</b> This observational study was done between October 2020 and December 2021. Cadaveric dissection was done and the required anatomic data were collected. <b>Results</b> The mean diameter of SCIA was 0.99 mm and the mean pedicle length was 2.97 cm. The average diameters of the medial and lateral perforators were 0.63 and 0.55 mm, respectively. The pedicle lengths of the medial and lateral perforators were 3.03 and 4.31 cm, respectively. The medial perforator was 5.63 cm lateral and 1.66 cm superior to the PT. It was 5.37 cm medial and 5.99 cm inferior to the ASIS. The lateral perforator was 7.97 cm lateral and 2.73 cm superior to the PT. It was 2.86 cm medial and 4.11 cm inferior to the ASIS. <b>Conclusion</b> Finding the exact location of the medial and the lateral perforators with respect to permanent bony landmarks and having an idea about their average pedicle length are useful for preoperative planning of the SCIP flap.</p>\",\"PeriodicalId\":47204,\"journal\":{\"name\":\"Indian Journal of Plastic Surgery\",\"volume\":\"58 3\",\"pages\":\"199-205\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-02-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12213017/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Plastic Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0045-1802643\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/6/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Plastic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0045-1802643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
A Cadaveric Study of the Anatomical Characteristics of the Superficial Circumflex Iliac Artery Perforator.
Background The superficial circumflex iliac artery perforator flap (SCIP flap) is an evolution of the conventional free groin flap. Even though the anatomical basis for SCIP flap is well established in general, the same is not described in a South Indian population. Objectives The objectives of our study were to determine the anatomical variations of the superficial circumflex iliac artery perforators (SCIA perforators) and describe them in relation to the nearby bony landmarks like anterior superior iliac spine (ASIS) and pubic tubercle (PT). Materials and Methods This observational study was done between October 2020 and December 2021. Cadaveric dissection was done and the required anatomic data were collected. Results The mean diameter of SCIA was 0.99 mm and the mean pedicle length was 2.97 cm. The average diameters of the medial and lateral perforators were 0.63 and 0.55 mm, respectively. The pedicle lengths of the medial and lateral perforators were 3.03 and 4.31 cm, respectively. The medial perforator was 5.63 cm lateral and 1.66 cm superior to the PT. It was 5.37 cm medial and 5.99 cm inferior to the ASIS. The lateral perforator was 7.97 cm lateral and 2.73 cm superior to the PT. It was 2.86 cm medial and 4.11 cm inferior to the ASIS. Conclusion Finding the exact location of the medial and the lateral perforators with respect to permanent bony landmarks and having an idea about their average pedicle length are useful for preoperative planning of the SCIP flap.
期刊介绍:
Indian Journal of Plastic Surgery (ISSN : 0970-0358) is biannual publication of the Association of Plastic Surgeons of India. Bibliographic listings: The journal is indexed with Bioline International, Caspur, DOAJ, EBSCO Publishing’s Electronic Databases, Expanded Academic ASAP, Genamics JournalSeek, Google Scholar, Health & Wellness Research Center, Health Reference Center Academic, Hinari, Index Copernicus, IndMed, OpenJGate, PubMed, Pubmed Central, Scimago Journal Ranking, SCOLOAR, SCOPUS, SIIC databases, SNEMB, Ulrich’s International Periodical Directory