Shaofei Zhang, Barbara L Parsons, Devon Fitzgerald, Anne Ashford, James Todd Auman, Tao Chen, Annette Dodge, Azeddine Elhajouji, Lena Pfaller, Shawn Harris, Jake Higgins, Cheryl A Hobbs, Francesco Marchetti, Matthew J Meier, Meagan B Myers, Jesse Salk, Rebecca Sahroui, David Schuster, Raja Settivari, Stephanie L Smith-Roe, Carole L Yauk, Jian Yan, Andrew Williams, Connie L Chen
{"title":"双工测序突变定量的可转移性、可重复性和敏感性。","authors":"Shaofei Zhang, Barbara L Parsons, Devon Fitzgerald, Anne Ashford, James Todd Auman, Tao Chen, Annette Dodge, Azeddine Elhajouji, Lena Pfaller, Shawn Harris, Jake Higgins, Cheryl A Hobbs, Francesco Marchetti, Matthew J Meier, Meagan B Myers, Jesse Salk, Rebecca Sahroui, David Schuster, Raja Settivari, Stephanie L Smith-Roe, Carole L Yauk, Jian Yan, Andrew Williams, Connie L Chen","doi":"10.1002/em.70020","DOIUrl":null,"url":null,"abstract":"<p><p>Duplex Sequencing (DS) is an ultra-accurate, error-corrected next generation sequencing (ecNGS) technology for mutation analysis. A working group (WG) within Health and Environmental Sciences Institute's Genetic Toxicology Technical Committee is investigating the suitability of ecNGS for regulatory mutagenicity testing, using DS as a model. Initial steps to promote acceptance require demonstrating technical reproducibility across DS-experienced and inexperienced laboratories and establishing the method's sensitivity relative to conventional tests. Thus, the WG conducted a 'reconstruction experiment' to evaluate the transferability, reproducibility, and sensitivity of DS. TwinStrand Biosciences first applied DS to establish mutation frequency (MF) in DNA samples extracted from the livers of an untreated Sprague Dawley rat, or rats treated with either 100 mg/kg/day benzo[a]pyrene (B[a]P) for ten days or 40 mg/kg/day N-ethyl-N-nitrosourea (ENU) for three days. Using the measured MF in these original samples, mixtures were then constructed using the B[a]P- and ENU-treated samples to create \"MF standards\" with target MFs 1.2-, 1.5-, and 2-fold greater than the untreated control. Aliquots of these standards were distributed to seven laboratories in North America and Europe. DS libraries were prepared by each laboratory and TwinStrand. All eight laboratories met library preparation and assay performance metrics to yield high quality sequencing data with MF in the expected 'MF standard' range. The measured MF and mutation spectra were nearly identical across the laboratories and a 2-fold increase in MF could readily be identified in all labs relative to the untreated controls. The results confirm the high reproducibility and sensitivity of DS for mutagenicity assessment.</p>","PeriodicalId":11791,"journal":{"name":"Environmental and Molecular Mutagenesis","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transferability, Reproducibility and Sensitivity of Mutation Quantification by Duplex Sequencing.\",\"authors\":\"Shaofei Zhang, Barbara L Parsons, Devon Fitzgerald, Anne Ashford, James Todd Auman, Tao Chen, Annette Dodge, Azeddine Elhajouji, Lena Pfaller, Shawn Harris, Jake Higgins, Cheryl A Hobbs, Francesco Marchetti, Matthew J Meier, Meagan B Myers, Jesse Salk, Rebecca Sahroui, David Schuster, Raja Settivari, Stephanie L Smith-Roe, Carole L Yauk, Jian Yan, Andrew Williams, Connie L Chen\",\"doi\":\"10.1002/em.70020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Duplex Sequencing (DS) is an ultra-accurate, error-corrected next generation sequencing (ecNGS) technology for mutation analysis. A working group (WG) within Health and Environmental Sciences Institute's Genetic Toxicology Technical Committee is investigating the suitability of ecNGS for regulatory mutagenicity testing, using DS as a model. Initial steps to promote acceptance require demonstrating technical reproducibility across DS-experienced and inexperienced laboratories and establishing the method's sensitivity relative to conventional tests. Thus, the WG conducted a 'reconstruction experiment' to evaluate the transferability, reproducibility, and sensitivity of DS. TwinStrand Biosciences first applied DS to establish mutation frequency (MF) in DNA samples extracted from the livers of an untreated Sprague Dawley rat, or rats treated with either 100 mg/kg/day benzo[a]pyrene (B[a]P) for ten days or 40 mg/kg/day N-ethyl-N-nitrosourea (ENU) for three days. Using the measured MF in these original samples, mixtures were then constructed using the B[a]P- and ENU-treated samples to create \\\"MF standards\\\" with target MFs 1.2-, 1.5-, and 2-fold greater than the untreated control. Aliquots of these standards were distributed to seven laboratories in North America and Europe. DS libraries were prepared by each laboratory and TwinStrand. All eight laboratories met library preparation and assay performance metrics to yield high quality sequencing data with MF in the expected 'MF standard' range. The measured MF and mutation spectra were nearly identical across the laboratories and a 2-fold increase in MF could readily be identified in all labs relative to the untreated controls. The results confirm the high reproducibility and sensitivity of DS for mutagenicity assessment.</p>\",\"PeriodicalId\":11791,\"journal\":{\"name\":\"Environmental and Molecular Mutagenesis\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental and Molecular Mutagenesis\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1002/em.70020\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental and Molecular Mutagenesis","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1002/em.70020","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Transferability, Reproducibility and Sensitivity of Mutation Quantification by Duplex Sequencing.
Duplex Sequencing (DS) is an ultra-accurate, error-corrected next generation sequencing (ecNGS) technology for mutation analysis. A working group (WG) within Health and Environmental Sciences Institute's Genetic Toxicology Technical Committee is investigating the suitability of ecNGS for regulatory mutagenicity testing, using DS as a model. Initial steps to promote acceptance require demonstrating technical reproducibility across DS-experienced and inexperienced laboratories and establishing the method's sensitivity relative to conventional tests. Thus, the WG conducted a 'reconstruction experiment' to evaluate the transferability, reproducibility, and sensitivity of DS. TwinStrand Biosciences first applied DS to establish mutation frequency (MF) in DNA samples extracted from the livers of an untreated Sprague Dawley rat, or rats treated with either 100 mg/kg/day benzo[a]pyrene (B[a]P) for ten days or 40 mg/kg/day N-ethyl-N-nitrosourea (ENU) for three days. Using the measured MF in these original samples, mixtures were then constructed using the B[a]P- and ENU-treated samples to create "MF standards" with target MFs 1.2-, 1.5-, and 2-fold greater than the untreated control. Aliquots of these standards were distributed to seven laboratories in North America and Europe. DS libraries were prepared by each laboratory and TwinStrand. All eight laboratories met library preparation and assay performance metrics to yield high quality sequencing data with MF in the expected 'MF standard' range. The measured MF and mutation spectra were nearly identical across the laboratories and a 2-fold increase in MF could readily be identified in all labs relative to the untreated controls. The results confirm the high reproducibility and sensitivity of DS for mutagenicity assessment.
期刊介绍:
Environmental and Molecular Mutagenesis publishes original research manuscripts, reviews and commentaries on topics related to six general areas, with an emphasis on subject matter most suited for the readership of EMM as outlined below. The journal is intended for investigators in fields such as molecular biology, biochemistry, microbiology, genetics and epigenetics, genomics and epigenomics, cancer research, neurobiology, heritable mutation, radiation biology, toxicology, and molecular & environmental epidemiology.