片剂诱发电磁干扰对腹部心脏装置的影响:一项基于模拟患者的研究

IF 1.7 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Yo Kajiyama M.D., Yusuke Kita M.D., Mayu Iwabuchi M.E., Tomomi Sekine M.E., Keishi Ogura M.E
{"title":"片剂诱发电磁干扰对腹部心脏装置的影响:一项基于模拟患者的研究","authors":"Yo Kajiyama M.D.,&nbsp;Yusuke Kita M.D.,&nbsp;Mayu Iwabuchi M.E.,&nbsp;Tomomi Sekine M.E.,&nbsp;Keishi Ogura M.E","doi":"10.1002/joa3.70136","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Electromagnetic interference (EMI) between tablet computers (tablets) and cardiac implantable electronic devices (CIEDs) in the abdomen of adults remains unclear.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We aimed to determine the magnetic flux density (MFD) of tablets, measure the distance at which EMI was triggered, and assess the susceptibility of abdominally implanted CIEDs to EMI.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>We studied 17 tablets and 2 CIED models. The measured MFD of tablets was 638 Gauss. EMI occurred at a 3.2 cm distance. A simulated patient using a tablet experienced EMI episodes for 357.2 s in 10 min.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Tablets may generate sufficient MFD to induce EMI in abdominally implanted CIEDs.</p>\n </section>\n </div>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"41 4","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70136","citationCount":"0","resultStr":"{\"title\":\"Impact of tablet-induced electromagnetic interference on abdominal cardiac devices: A study based on simulated patients\",\"authors\":\"Yo Kajiyama M.D.,&nbsp;Yusuke Kita M.D.,&nbsp;Mayu Iwabuchi M.E.,&nbsp;Tomomi Sekine M.E.,&nbsp;Keishi Ogura M.E\",\"doi\":\"10.1002/joa3.70136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Electromagnetic interference (EMI) between tablet computers (tablets) and cardiac implantable electronic devices (CIEDs) in the abdomen of adults remains unclear.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>We aimed to determine the magnetic flux density (MFD) of tablets, measure the distance at which EMI was triggered, and assess the susceptibility of abdominally implanted CIEDs to EMI.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>We studied 17 tablets and 2 CIED models. The measured MFD of tablets was 638 Gauss. EMI occurred at a 3.2 cm distance. A simulated patient using a tablet experienced EMI episodes for 357.2 s in 10 min.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Tablets may generate sufficient MFD to induce EMI in abdominally implanted CIEDs.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15174,\"journal\":{\"name\":\"Journal of Arrhythmia\",\"volume\":\"41 4\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.70136\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70136\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.70136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

成人腹部平板电脑与心脏植入式电子设备之间的电磁干扰(EMI)尚不清楚。方法测定片剂的磁通密度(MFD),测量诱发电磁干扰的距离,评价腹腔植入cied对电磁干扰的易感性。结果共研究17片和2个CIED模型。测得片剂的MFD为638高斯。电磁干扰发生在3.2 cm的距离。一个使用片剂的模拟患者在10分钟内经历了357.2秒的EMI发作。结论片剂可产生足够的MFD,诱发腹腔植入cied的EMI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Impact of tablet-induced electromagnetic interference on abdominal cardiac devices: A study based on simulated patients

Impact of tablet-induced electromagnetic interference on abdominal cardiac devices: A study based on simulated patients

Background

Electromagnetic interference (EMI) between tablet computers (tablets) and cardiac implantable electronic devices (CIEDs) in the abdomen of adults remains unclear.

Methods

We aimed to determine the magnetic flux density (MFD) of tablets, measure the distance at which EMI was triggered, and assess the susceptibility of abdominally implanted CIEDs to EMI.

Results

We studied 17 tablets and 2 CIED models. The measured MFD of tablets was 638 Gauss. EMI occurred at a 3.2 cm distance. A simulated patient using a tablet experienced EMI episodes for 357.2 s in 10 min.

Conclusions

Tablets may generate sufficient MFD to induce EMI in abdominally implanted CIEDs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信