Glen Katsnelson, Marcus Salvatori, George Djaiani, Elise Greer, Jordan Tarshis, Rita Katznelson
{"title":"连续血糖监测装置在接受高压氧治疗的糖尿病患者中的安全性和有效性:一项范围综述。","authors":"Glen Katsnelson, Marcus Salvatori, George Djaiani, Elise Greer, Jordan Tarshis, Rita Katznelson","doi":"10.28920/dhm55.2.164-172","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Continuous glucose monitoring devices (CGMs) have emerged as an effective approach to optimise glycaemic control for individuals living with diabetes mellitus. Despite CGMs offering improved patient satisfaction and quality of life, they have been primarily validated for outpatient and home use. This has posed a challenge for patients and providers who wish to incorporate CGMs into clinical settings such as hyperbaric oxygen therapy (HBOT). Those with advanced diabetes mellitus who have diabetic foot ulcers that are refractory to treatment are among the most prevalent users of HBOT. However, those who prefer to use their CGM during HBOT face uncertainty regarding the accuracy and safety of their device under hyperbaric conditions.</p><p><strong>Methods: </strong>The product specifications of commonly used CGMs were collated. In addition, a scoping review of the literature was conducted where Medline, Embase, and Scopus were searched for reports that assess the accuracy or safety of CGMs in hyperbaric conditions.</p><p><strong>Results: </strong>The product specifications of commonly used CGMs by Dexcom, Abbott, Medtronic, and Senseonics demonstrate a maximum validated pressure of approximately 106 kPa (1.06 atmospheres absolute). Our literature search identified five reports, of which four focused on accuracy and one focused on safety of CGMs in hyperbaric conditions. Treatments were conducted in multiplace chambers and cumulatively described 39 participants, of whom 12 have diabetes. Although heterogeneous in nature, the reports generally supported the safety and accuracy of CGMs in hyperbaric conditions.</p><p><strong>Conclusions: </strong>The safety and accuracy of using CGMs during HBOT warrants further investigation. CGMs have not been validated for repeated exposure to hyperbaric conditions and should not be used in oxygen pressurised monoplace chambers until further safety data is available. We provide practical recommendations for use of CGMs in multiplace chambers.</p>","PeriodicalId":11296,"journal":{"name":"Diving and hyperbaric medicine","volume":"55 2","pages":"164-172"},"PeriodicalIF":0.8000,"publicationDate":"2025-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Safety and efficacy of continuous glucose monitoring devices in individuals with diabetes undergoing hyperbaric oxygen therapy: a scoping review.\",\"authors\":\"Glen Katsnelson, Marcus Salvatori, George Djaiani, Elise Greer, Jordan Tarshis, Rita Katznelson\",\"doi\":\"10.28920/dhm55.2.164-172\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Continuous glucose monitoring devices (CGMs) have emerged as an effective approach to optimise glycaemic control for individuals living with diabetes mellitus. Despite CGMs offering improved patient satisfaction and quality of life, they have been primarily validated for outpatient and home use. This has posed a challenge for patients and providers who wish to incorporate CGMs into clinical settings such as hyperbaric oxygen therapy (HBOT). Those with advanced diabetes mellitus who have diabetic foot ulcers that are refractory to treatment are among the most prevalent users of HBOT. However, those who prefer to use their CGM during HBOT face uncertainty regarding the accuracy and safety of their device under hyperbaric conditions.</p><p><strong>Methods: </strong>The product specifications of commonly used CGMs were collated. In addition, a scoping review of the literature was conducted where Medline, Embase, and Scopus were searched for reports that assess the accuracy or safety of CGMs in hyperbaric conditions.</p><p><strong>Results: </strong>The product specifications of commonly used CGMs by Dexcom, Abbott, Medtronic, and Senseonics demonstrate a maximum validated pressure of approximately 106 kPa (1.06 atmospheres absolute). Our literature search identified five reports, of which four focused on accuracy and one focused on safety of CGMs in hyperbaric conditions. Treatments were conducted in multiplace chambers and cumulatively described 39 participants, of whom 12 have diabetes. Although heterogeneous in nature, the reports generally supported the safety and accuracy of CGMs in hyperbaric conditions.</p><p><strong>Conclusions: </strong>The safety and accuracy of using CGMs during HBOT warrants further investigation. CGMs have not been validated for repeated exposure to hyperbaric conditions and should not be used in oxygen pressurised monoplace chambers until further safety data is available. We provide practical recommendations for use of CGMs in multiplace chambers.</p>\",\"PeriodicalId\":11296,\"journal\":{\"name\":\"Diving and hyperbaric medicine\",\"volume\":\"55 2\",\"pages\":\"164-172\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2025-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diving and hyperbaric medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.28920/dhm55.2.164-172\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diving and hyperbaric medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.28920/dhm55.2.164-172","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
Safety and efficacy of continuous glucose monitoring devices in individuals with diabetes undergoing hyperbaric oxygen therapy: a scoping review.
Introduction: Continuous glucose monitoring devices (CGMs) have emerged as an effective approach to optimise glycaemic control for individuals living with diabetes mellitus. Despite CGMs offering improved patient satisfaction and quality of life, they have been primarily validated for outpatient and home use. This has posed a challenge for patients and providers who wish to incorporate CGMs into clinical settings such as hyperbaric oxygen therapy (HBOT). Those with advanced diabetes mellitus who have diabetic foot ulcers that are refractory to treatment are among the most prevalent users of HBOT. However, those who prefer to use their CGM during HBOT face uncertainty regarding the accuracy and safety of their device under hyperbaric conditions.
Methods: The product specifications of commonly used CGMs were collated. In addition, a scoping review of the literature was conducted where Medline, Embase, and Scopus were searched for reports that assess the accuracy or safety of CGMs in hyperbaric conditions.
Results: The product specifications of commonly used CGMs by Dexcom, Abbott, Medtronic, and Senseonics demonstrate a maximum validated pressure of approximately 106 kPa (1.06 atmospheres absolute). Our literature search identified five reports, of which four focused on accuracy and one focused on safety of CGMs in hyperbaric conditions. Treatments were conducted in multiplace chambers and cumulatively described 39 participants, of whom 12 have diabetes. Although heterogeneous in nature, the reports generally supported the safety and accuracy of CGMs in hyperbaric conditions.
Conclusions: The safety and accuracy of using CGMs during HBOT warrants further investigation. CGMs have not been validated for repeated exposure to hyperbaric conditions and should not be used in oxygen pressurised monoplace chambers until further safety data is available. We provide practical recommendations for use of CGMs in multiplace chambers.
期刊介绍:
Diving and Hyperbaric Medicine (DHM) is the combined journal of the South Pacific Underwater Medicine Society (SPUMS) and the European Underwater and Baromedical Society (EUBS). It seeks to publish papers of high quality on all aspects of diving and hyperbaric medicine of interest to diving medical professionals, physicians of all specialties, scientists, members of the diving and hyperbaric industries, and divers. Manuscripts must be offered exclusively to Diving and Hyperbaric Medicine, unless clearly authenticated copyright exemption accompaniesthe manuscript. All manuscripts will be subject to peer review. Accepted contributions will also be subject to editing.