Michael Schatz, Matthias Streun, Sven Jovanovic, Rüdiger-A Eichel, Josef Granwehr
{"title":"通过b0和b1的现场模拟与实验相匹配,建立了operando核磁共振池电化学系统设计的工作流程。","authors":"Michael Schatz, Matthias Streun, Sven Jovanovic, Rüdiger-A Eichel, Josef Granwehr","doi":"10.5194/mr-5-167-2024","DOIUrl":null,"url":null,"abstract":"<p><p>Combining electrochemistry (EC) and nuclear magnetic resonance (NMR) techniques has evolved from a challenging concept to an adaptable and versatile method for battery and electrolysis research. Continuous advancements in NMR hardware have fostered improved homogeneity of the static magnetic field, <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> , and the radio frequency field, <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> , yet fundamental challenges caused by introducing essential conductive components into the NMR sensitive volume remain. Cell designs in EC-NMR have largely been improved empirically, at times supported by magnetic field simulations. To propel systematic improvements of cell concepts, a workflow for a qualitative and semi-quantitative description of both <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> and <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> distortions is provided in this study. Three-dimensional finite element method (FEM) simulations of both <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> and <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> fields were employed to investigate cell structures with electrodes oriented perpendicular to <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> , which allow realistic EC-NMR measurements for battery and electrolysis applications. Particular attention is paid to field distributions in the immediate vicinity of electrodes, which is of prime interest for electrochemical processes. Using a cell with a small void outside the electrochemical active region, the relevance of design details and bubble formation is demonstrated. Moreover, <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> amplifications in coin cells provide an explanation for unexpectedly high sensitivity in previous EC-NMR studies, implying the potential for selective excitation of spins close to electrode surfaces. The correlation of this amplification effect with coin geometry is described by empirical expressions. The simulations were validated experimentally utilising frequency-encoded <sup>1</sup>H profile imaging and chemical shift imaging of <sup>1</sup>H, <sup>13</sup>C, and <sup>23</sup>Na resonances of <math> <mrow><msub><mi>NaHCO</mi> <mn>3</mn></msub> </mrow> </math> electrolyte. Finally, the theoretical and experimental results are distilled into design guidelines for EC-NMR cells.</p>","PeriodicalId":93333,"journal":{"name":"Magnetic resonance (Gottingen, Germany)","volume":"5 2","pages":"167-180"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12178131/pdf/","citationCount":"0","resultStr":"{\"title\":\"Workflow for systematic design of electrochemical in operando NMR cells by matching <i>B</i> <sub>0</sub> and <i>B</i> <sub>1</sub> field simulations with experiments.\",\"authors\":\"Michael Schatz, Matthias Streun, Sven Jovanovic, Rüdiger-A Eichel, Josef Granwehr\",\"doi\":\"10.5194/mr-5-167-2024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Combining electrochemistry (EC) and nuclear magnetic resonance (NMR) techniques has evolved from a challenging concept to an adaptable and versatile method for battery and electrolysis research. Continuous advancements in NMR hardware have fostered improved homogeneity of the static magnetic field, <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> , and the radio frequency field, <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> , yet fundamental challenges caused by introducing essential conductive components into the NMR sensitive volume remain. Cell designs in EC-NMR have largely been improved empirically, at times supported by magnetic field simulations. To propel systematic improvements of cell concepts, a workflow for a qualitative and semi-quantitative description of both <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> and <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> distortions is provided in this study. Three-dimensional finite element method (FEM) simulations of both <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> and <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> fields were employed to investigate cell structures with electrodes oriented perpendicular to <math> <mrow><msub><mi>B</mi> <mn>0</mn></msub> </mrow> </math> , which allow realistic EC-NMR measurements for battery and electrolysis applications. Particular attention is paid to field distributions in the immediate vicinity of electrodes, which is of prime interest for electrochemical processes. Using a cell with a small void outside the electrochemical active region, the relevance of design details and bubble formation is demonstrated. Moreover, <math> <mrow><msub><mi>B</mi> <mn>1</mn></msub> </mrow> </math> amplifications in coin cells provide an explanation for unexpectedly high sensitivity in previous EC-NMR studies, implying the potential for selective excitation of spins close to electrode surfaces. The correlation of this amplification effect with coin geometry is described by empirical expressions. The simulations were validated experimentally utilising frequency-encoded <sup>1</sup>H profile imaging and chemical shift imaging of <sup>1</sup>H, <sup>13</sup>C, and <sup>23</sup>Na resonances of <math> <mrow><msub><mi>NaHCO</mi> <mn>3</mn></msub> </mrow> </math> electrolyte. Finally, the theoretical and experimental results are distilled into design guidelines for EC-NMR cells.</p>\",\"PeriodicalId\":93333,\"journal\":{\"name\":\"Magnetic resonance (Gottingen, Germany)\",\"volume\":\"5 2\",\"pages\":\"167-180\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12178131/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance (Gottingen, Germany)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5194/mr-5-167-2024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance (Gottingen, Germany)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/mr-5-167-2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
Workflow for systematic design of electrochemical in operando NMR cells by matching B0 and B1 field simulations with experiments.
Combining electrochemistry (EC) and nuclear magnetic resonance (NMR) techniques has evolved from a challenging concept to an adaptable and versatile method for battery and electrolysis research. Continuous advancements in NMR hardware have fostered improved homogeneity of the static magnetic field, , and the radio frequency field, , yet fundamental challenges caused by introducing essential conductive components into the NMR sensitive volume remain. Cell designs in EC-NMR have largely been improved empirically, at times supported by magnetic field simulations. To propel systematic improvements of cell concepts, a workflow for a qualitative and semi-quantitative description of both and distortions is provided in this study. Three-dimensional finite element method (FEM) simulations of both and fields were employed to investigate cell structures with electrodes oriented perpendicular to , which allow realistic EC-NMR measurements for battery and electrolysis applications. Particular attention is paid to field distributions in the immediate vicinity of electrodes, which is of prime interest for electrochemical processes. Using a cell with a small void outside the electrochemical active region, the relevance of design details and bubble formation is demonstrated. Moreover, amplifications in coin cells provide an explanation for unexpectedly high sensitivity in previous EC-NMR studies, implying the potential for selective excitation of spins close to electrode surfaces. The correlation of this amplification effect with coin geometry is described by empirical expressions. The simulations were validated experimentally utilising frequency-encoded 1H profile imaging and chemical shift imaging of 1H, 13C, and 23Na resonances of electrolyte. Finally, the theoretical and experimental results are distilled into design guidelines for EC-NMR cells.