Edoardo Mannucci, Basilio Pintaudi, Maria Elena Lunati, Paolo Fiorina
{"title":"糖尿病患者注射胰岛素的针型特点及经验。","authors":"Edoardo Mannucci, Basilio Pintaudi, Maria Elena Lunati, Paolo Fiorina","doi":"10.1007/s00592-025-02538-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Fear of pain during insulin injection, using pen injectors, still represents a barrier to diabetes treatment. The development of smaller and thinner needles has improved comfort during the injection, but the influence of other needle geometry features, has been less thoroughly assessed. The aim of this review, is to evaluate the role that pen needle geometry plays in determining patient experience during insulin injection.</p><p><strong>Methods: </strong>A literature search was conducted in PubMed and Scopus to identify the publications assessing the effect of needle geometry and quality on insertion force and pain, experienced by the patient during injection. 22 studies were included in this review. All studies included, at minimum, an evaluation of the perceived injection pain, using a Visual Analogue Scale (VAS).</p><p><strong>Results: </strong>The clinical evidence demonstrated that in addition to the pain reduction experienced with increasing needle gauge, other geometrical features such as shorter needle length, thinner wall design, improved tip geometry and coating with lubricant, are associated with reduced injection pain and improved patient experience. Furthermore, it was indicated that the needle features shown to help reduce the experienced pain, would not negatively affect the frequency and intensity of injection related site reactions or needle-related failures, such as breakage and bending.</p><p><strong>Conclusions: </strong>Pen needle geometry affects the insulin injection experience of diabetic patients. Increased needle gauge, shorter length, improved tip design and mechanical characteristics of the needle are all associated with a perceived reduction of the pain during insulin injection and an overall improved patient experience.</p>","PeriodicalId":6921,"journal":{"name":"Acta Diabetologica","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Needle characteristics and the insulin injection experience in patients with diabetes.\",\"authors\":\"Edoardo Mannucci, Basilio Pintaudi, Maria Elena Lunati, Paolo Fiorina\",\"doi\":\"10.1007/s00592-025-02538-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Fear of pain during insulin injection, using pen injectors, still represents a barrier to diabetes treatment. The development of smaller and thinner needles has improved comfort during the injection, but the influence of other needle geometry features, has been less thoroughly assessed. The aim of this review, is to evaluate the role that pen needle geometry plays in determining patient experience during insulin injection.</p><p><strong>Methods: </strong>A literature search was conducted in PubMed and Scopus to identify the publications assessing the effect of needle geometry and quality on insertion force and pain, experienced by the patient during injection. 22 studies were included in this review. All studies included, at minimum, an evaluation of the perceived injection pain, using a Visual Analogue Scale (VAS).</p><p><strong>Results: </strong>The clinical evidence demonstrated that in addition to the pain reduction experienced with increasing needle gauge, other geometrical features such as shorter needle length, thinner wall design, improved tip geometry and coating with lubricant, are associated with reduced injection pain and improved patient experience. Furthermore, it was indicated that the needle features shown to help reduce the experienced pain, would not negatively affect the frequency and intensity of injection related site reactions or needle-related failures, such as breakage and bending.</p><p><strong>Conclusions: </strong>Pen needle geometry affects the insulin injection experience of diabetic patients. Increased needle gauge, shorter length, improved tip design and mechanical characteristics of the needle are all associated with a perceived reduction of the pain during insulin injection and an overall improved patient experience.</p>\",\"PeriodicalId\":6921,\"journal\":{\"name\":\"Acta Diabetologica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Diabetologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00592-025-02538-8\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Diabetologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00592-025-02538-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Needle characteristics and the insulin injection experience in patients with diabetes.
Background: Fear of pain during insulin injection, using pen injectors, still represents a barrier to diabetes treatment. The development of smaller and thinner needles has improved comfort during the injection, but the influence of other needle geometry features, has been less thoroughly assessed. The aim of this review, is to evaluate the role that pen needle geometry plays in determining patient experience during insulin injection.
Methods: A literature search was conducted in PubMed and Scopus to identify the publications assessing the effect of needle geometry and quality on insertion force and pain, experienced by the patient during injection. 22 studies were included in this review. All studies included, at minimum, an evaluation of the perceived injection pain, using a Visual Analogue Scale (VAS).
Results: The clinical evidence demonstrated that in addition to the pain reduction experienced with increasing needle gauge, other geometrical features such as shorter needle length, thinner wall design, improved tip geometry and coating with lubricant, are associated with reduced injection pain and improved patient experience. Furthermore, it was indicated that the needle features shown to help reduce the experienced pain, would not negatively affect the frequency and intensity of injection related site reactions or needle-related failures, such as breakage and bending.
Conclusions: Pen needle geometry affects the insulin injection experience of diabetic patients. Increased needle gauge, shorter length, improved tip design and mechanical characteristics of the needle are all associated with a perceived reduction of the pain during insulin injection and an overall improved patient experience.
期刊介绍:
Acta Diabetologica is a journal that publishes reports of experimental and clinical research on diabetes mellitus and related metabolic diseases. Original contributions on biochemical, physiological, pathophysiological and clinical aspects of research on diabetes and metabolic diseases are welcome. Reports are published in the form of original articles, short communications and letters to the editor. Invited reviews and editorials are also published. A Methodology forum, which publishes contributions on methodological aspects of diabetes in vivo and in vitro, is also available. The Editor-in-chief will be pleased to consider articles describing new techniques (e.g., new transplantation methods, metabolic models), of innovative importance in the field of diabetes/metabolism. Finally, workshop reports are also welcome in Acta Diabetologica.