{"title":"UHPLC-MS/MS手性定量分离KRAS抑制剂Sotorasib:方法验证及大鼠血浆对映选择药代动力学评价","authors":"Jony Susanna Kandula, Keyur Parmar, A. R. Priyadharshni, Abhay Kumar, P. Radhakrishnanand","doi":"10.1002/chir.70037","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>In this research, estimation of enantioselective pharmacokinetics and biological interconversion of sotorasib were investigated. This is the first report for the novel chiral liquid chromatography–tandem mass spectrometry method for the enantioselective pharmacokinetics determination in biological matrix. Attempts were made to achieve separation in reverse phase mode with mass compatible mobile phase. The baseline chiral separation was achieved with a mobile phase consisting of acetonitrile and aqueous ammonium bicarbonate (15 mM; 95/5 v/v) on Chiralpak IC (250 × 4.6 mm, 5 μm). Positive electrospray ionization was used for monitoring multiple reactions by triple quadrupole. The developed bioanalytical method was validated for each SOT enantiomer, assessing selectivity and specificity, linearity, accuracy, precision, recovery, matrix effect, dilution integrity, and stability. The lower limit of quantification was identified as 1 ng/mL for both SOT enantiomers. The results were found to be in compliance with the bioanalytical method validation guideline. The preclinical study revealed the disparate pharmacokinetic profile between the (<i>R</i>) and (<i>S</i>)-sotorasib, after single oral administration (10 mg/kg) to rats. This is the first investigational evidence of enantioselective behavior of sotorasib in vivo. The results demonstrated that lower maximum concentration, area under curve, and higher clearance and volume of distribution for (<i>R</i>)-sotorasib reveal the poorer bioavailability and higher elimination rate. The study provides insights in controlling the enantiomeric impurity in quality control aspects. This research also provides a reference for clinical practice and supports further research in distomer toxicity, enantioselective drug metabolism, and drug interactions.</p>\n </div>","PeriodicalId":10170,"journal":{"name":"Chirality","volume":"37 6","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative Chiral Separations on KRAS Inhibitor Sotorasib by UHPLC-MS/MS: Method Validation and Enantioselective Pharmacokinetics Assessment in Rat Plasma\",\"authors\":\"Jony Susanna Kandula, Keyur Parmar, A. R. Priyadharshni, Abhay Kumar, P. Radhakrishnanand\",\"doi\":\"10.1002/chir.70037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>In this research, estimation of enantioselective pharmacokinetics and biological interconversion of sotorasib were investigated. This is the first report for the novel chiral liquid chromatography–tandem mass spectrometry method for the enantioselective pharmacokinetics determination in biological matrix. Attempts were made to achieve separation in reverse phase mode with mass compatible mobile phase. The baseline chiral separation was achieved with a mobile phase consisting of acetonitrile and aqueous ammonium bicarbonate (15 mM; 95/5 v/v) on Chiralpak IC (250 × 4.6 mm, 5 μm). Positive electrospray ionization was used for monitoring multiple reactions by triple quadrupole. The developed bioanalytical method was validated for each SOT enantiomer, assessing selectivity and specificity, linearity, accuracy, precision, recovery, matrix effect, dilution integrity, and stability. The lower limit of quantification was identified as 1 ng/mL for both SOT enantiomers. The results were found to be in compliance with the bioanalytical method validation guideline. The preclinical study revealed the disparate pharmacokinetic profile between the (<i>R</i>) and (<i>S</i>)-sotorasib, after single oral administration (10 mg/kg) to rats. This is the first investigational evidence of enantioselective behavior of sotorasib in vivo. The results demonstrated that lower maximum concentration, area under curve, and higher clearance and volume of distribution for (<i>R</i>)-sotorasib reveal the poorer bioavailability and higher elimination rate. The study provides insights in controlling the enantiomeric impurity in quality control aspects. This research also provides a reference for clinical practice and supports further research in distomer toxicity, enantioselective drug metabolism, and drug interactions.</p>\\n </div>\",\"PeriodicalId\":10170,\"journal\":{\"name\":\"Chirality\",\"volume\":\"37 6\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chirality\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/chir.70037\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chirality","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/chir.70037","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
摘要
本研究对索氏菌的对映选择性药代动力学和生物相互转化进行了研究。本文首次报道了用手性液相色谱-串联质谱法测定生物基质中对映选择性药代动力学的方法。尝试用质量相容的流动相实现反相分离。基线手性分离是用乙腈和碳酸氢铵(15 mM;Chiralpak IC (250 × 4.6 mm, 5 μm)上的95/ 5v /v。正电喷雾电离法用于三重四极杆监测多重反应。建立的生物分析方法对每种SOT对映体进行了验证,评估了选择性和特异性、线性、准确度、精密度、回收率、基质效应、稀释完整性和稳定性。两种SOT对映体的定量下限均为1 ng/mL。结果符合生物分析方法验证指南。临床前研究显示(R)和(S)-sotorasib在大鼠单次口服(10 mg/kg)后具有不同的药代动力学特征。这是sotorasib在体内对映选择性行为的第一个研究证据。结果表明,(R)-sotorasib的最大浓度、曲线下面积较低,清除率和分布体积较大,表明其生物利用度较差,去除率较高。本研究为对映体杂质的控制提供了质量控制方面的见解。该研究为临床实践提供了参考,并为进一步研究二聚体毒性、对映体选择性药物代谢和药物相互作用提供了支持。
Quantitative Chiral Separations on KRAS Inhibitor Sotorasib by UHPLC-MS/MS: Method Validation and Enantioselective Pharmacokinetics Assessment in Rat Plasma
In this research, estimation of enantioselective pharmacokinetics and biological interconversion of sotorasib were investigated. This is the first report for the novel chiral liquid chromatography–tandem mass spectrometry method for the enantioselective pharmacokinetics determination in biological matrix. Attempts were made to achieve separation in reverse phase mode with mass compatible mobile phase. The baseline chiral separation was achieved with a mobile phase consisting of acetonitrile and aqueous ammonium bicarbonate (15 mM; 95/5 v/v) on Chiralpak IC (250 × 4.6 mm, 5 μm). Positive electrospray ionization was used for monitoring multiple reactions by triple quadrupole. The developed bioanalytical method was validated for each SOT enantiomer, assessing selectivity and specificity, linearity, accuracy, precision, recovery, matrix effect, dilution integrity, and stability. The lower limit of quantification was identified as 1 ng/mL for both SOT enantiomers. The results were found to be in compliance with the bioanalytical method validation guideline. The preclinical study revealed the disparate pharmacokinetic profile between the (R) and (S)-sotorasib, after single oral administration (10 mg/kg) to rats. This is the first investigational evidence of enantioselective behavior of sotorasib in vivo. The results demonstrated that lower maximum concentration, area under curve, and higher clearance and volume of distribution for (R)-sotorasib reveal the poorer bioavailability and higher elimination rate. The study provides insights in controlling the enantiomeric impurity in quality control aspects. This research also provides a reference for clinical practice and supports further research in distomer toxicity, enantioselective drug metabolism, and drug interactions.
期刊介绍:
The main aim of the journal is to publish original contributions of scientific work on the role of chirality in chemistry and biochemistry in respect to biological, chemical, materials, pharmacological, spectroscopic and physical properties.
Papers on the chemistry (physiochemical, preparative synthetic, and analytical), physics, pharmacology, clinical pharmacology, toxicology, and other biological aspects of chiral molecules will be published.