Kitaro Yoshimitsu, Ken Masamune, Fujio Miyawaki
{"title":"用自动擦洗护士机器人提高手术效率:专注于自动器械插入。","authors":"Kitaro Yoshimitsu, Ken Masamune, Fujio Miyawaki","doi":"10.1007/s11548-025-03433-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To address the chronic shortage of skilled scrub nurses, we propose the development of a scrub nurse robot (SNR). This paper describes the third-generation of our SNR, which implements the automatic insertion of surgical instruments (AISI). We focused on optimizing the instrument provision part of the instrument exchange task, which is a crucial role of the scrub nurse.</p><p><strong>Methods: </strong>The third-generation SNR detects the moment when an operating surgeon withdraws an instrument after use from the trocar cannula, automatically conveys the next instrument to the cannula, and inserts only its tip into the cannula. Thereafter, the surgeon is required to grip the instrument and to push it fully into the cannula. This robotic function is designated as AISI. The following three combinations were compared: (1) third-generation SNR and surgeon stand-ins in a laboratory experiment, (2) three human scrub nurses and a skilled expert surgeon in three real surgical cases, (3) second-generation SNR and surgeon stand-ins in a laboratory experiment.</p><p><strong>Results: </strong>The third-generation SNR and surgeon stand-ins were 53% slower and 34% faster, respectively, in targeting the instruments during the instrument exchange sequence compared with the actual OR nurse-surgeon pair and the second-generation SNR-stand-in pair. The average \"eyes-off\" time of the stand-ins assisted by the third-generation SNR was 0.41 s (0 s in 92 out of 138 trials), whereas that of the real surgeon in clinical cases had a mean of 1.47 (N = 138) (range, 0.69-7.24 s) when using the second-generation SNR.</p><p><strong>Conclusion: </strong>Third-generation SNR with AISI can enhance operative efficiency by contributing to smooth instrument exchange, which enhances the surgeon's ability to concentrate on a surgical procedure without interrupting the intraoperative surgical rhythm.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhancing surgical efficiency with an automated scrub nurse robot: a focus on automatic instrument insertion.\",\"authors\":\"Kitaro Yoshimitsu, Ken Masamune, Fujio Miyawaki\",\"doi\":\"10.1007/s11548-025-03433-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To address the chronic shortage of skilled scrub nurses, we propose the development of a scrub nurse robot (SNR). This paper describes the third-generation of our SNR, which implements the automatic insertion of surgical instruments (AISI). We focused on optimizing the instrument provision part of the instrument exchange task, which is a crucial role of the scrub nurse.</p><p><strong>Methods: </strong>The third-generation SNR detects the moment when an operating surgeon withdraws an instrument after use from the trocar cannula, automatically conveys the next instrument to the cannula, and inserts only its tip into the cannula. Thereafter, the surgeon is required to grip the instrument and to push it fully into the cannula. This robotic function is designated as AISI. The following three combinations were compared: (1) third-generation SNR and surgeon stand-ins in a laboratory experiment, (2) three human scrub nurses and a skilled expert surgeon in three real surgical cases, (3) second-generation SNR and surgeon stand-ins in a laboratory experiment.</p><p><strong>Results: </strong>The third-generation SNR and surgeon stand-ins were 53% slower and 34% faster, respectively, in targeting the instruments during the instrument exchange sequence compared with the actual OR nurse-surgeon pair and the second-generation SNR-stand-in pair. The average \\\"eyes-off\\\" time of the stand-ins assisted by the third-generation SNR was 0.41 s (0 s in 92 out of 138 trials), whereas that of the real surgeon in clinical cases had a mean of 1.47 (N = 138) (range, 0.69-7.24 s) when using the second-generation SNR.</p><p><strong>Conclusion: </strong>Third-generation SNR with AISI can enhance operative efficiency by contributing to smooth instrument exchange, which enhances the surgeon's ability to concentrate on a surgical procedure without interrupting the intraoperative surgical rhythm.</p>\",\"PeriodicalId\":51251,\"journal\":{\"name\":\"International Journal of Computer Assisted Radiology and Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computer Assisted Radiology and Surgery\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s11548-025-03433-x\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-025-03433-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:为了解决熟练的护理人员长期短缺的问题,我们提出开发一种护理机器人(SNR)。本文介绍了实现手术器械自动插入(AISI)的第三代信噪比。我们将重点放在优化器械交换任务中的器械提供部分,这是擦洗护士的关键角色。方法:第三代信噪比检测手术医生从套管针套管中取出器械的瞬间,自动将下一个器械移至套管中,仅将其尖端插入套管。之后,外科医生需要握住器械并将其完全推入套管。这种机器人功能被称为AISI。比较以下三种组合:(1)实验室实验中的第三代信噪比与外科医生替身;(2)3例真实手术病例中的3名人工护理和1名熟练的专家外科医生;(3)实验室实验中的第二代信噪比与外科医生替身。结果:与实际手术室护士-外科医生配对和第二代SNR-替代配对相比,第三代SNR和外科医生替代配对在器械交换过程中瞄准器械的速度分别慢53%和34%。在第三代信噪比的辅助下,替身医生的平均“脱眼”时间为0.41 s(138个试验中有92个试验为0 s),而在临床病例中,使用第二代信噪比的真实外科医生的平均“脱眼”时间为1.47 s (N = 138)(范围为0.69-7.24 s)。结论:采用AISI的第三代信噪比可以提高手术效率,有助于器械的顺利交换,提高外科医生在不中断术中手术节奏的情况下专注于手术的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhancing surgical efficiency with an automated scrub nurse robot: a focus on automatic instrument insertion.

Purpose: To address the chronic shortage of skilled scrub nurses, we propose the development of a scrub nurse robot (SNR). This paper describes the third-generation of our SNR, which implements the automatic insertion of surgical instruments (AISI). We focused on optimizing the instrument provision part of the instrument exchange task, which is a crucial role of the scrub nurse.

Methods: The third-generation SNR detects the moment when an operating surgeon withdraws an instrument after use from the trocar cannula, automatically conveys the next instrument to the cannula, and inserts only its tip into the cannula. Thereafter, the surgeon is required to grip the instrument and to push it fully into the cannula. This robotic function is designated as AISI. The following three combinations were compared: (1) third-generation SNR and surgeon stand-ins in a laboratory experiment, (2) three human scrub nurses and a skilled expert surgeon in three real surgical cases, (3) second-generation SNR and surgeon stand-ins in a laboratory experiment.

Results: The third-generation SNR and surgeon stand-ins were 53% slower and 34% faster, respectively, in targeting the instruments during the instrument exchange sequence compared with the actual OR nurse-surgeon pair and the second-generation SNR-stand-in pair. The average "eyes-off" time of the stand-ins assisted by the third-generation SNR was 0.41 s (0 s in 92 out of 138 trials), whereas that of the real surgeon in clinical cases had a mean of 1.47 (N = 138) (range, 0.69-7.24 s) when using the second-generation SNR.

Conclusion: Third-generation SNR with AISI can enhance operative efficiency by contributing to smooth instrument exchange, which enhances the surgeon's ability to concentrate on a surgical procedure without interrupting the intraoperative surgical rhythm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信